This study presents an electromagnetically-actuated reciprocating pump for high-flow-rate microfluidic applications. The pump comprises four major components, namely a lower glass plate containing a copper microcoil, a middle PMMA plate incorporating a PDMS diaphragm with a surface-mounted magnet, upper PMMA channel plates, and a ball-type check valve located at the channel inlet. When an AC current is passed through the microcoil, an alternating electromagnetic force is established between the coil and the magnet. The resulting bi-directional deflection of the PDMS diaphragm causes the check-valve to open and close; thereby creating a pumping effect. The experimental results show that a coil input current of 0.4 A generates an electromagnetic force of 47 mN and a diaphragm deflection of 108 mu m. Given an actuating voltage of 3 V and a driving frequency of 15 Hz, the flow rate is found to be 13.2 mL/min under zero head pressure conditions.
引用
收藏
页码:13075 / 13087
页数:13
相关论文
共 50 条
  • [1] Automated and programmable electromagnetically actuated valves for microfluidic applications
    Pradeep, Aarathi
    Raj, Vineeth S.
    Stanley, John
    Nair, Bipin G.
    Babu, T. G. Satheesh
    SENSORS AND ACTUATORS A-PHYSICAL, 2018, 283 : 79 - 86
  • [2] HIGH-FLOW-RATE HYDROXYLAPATITES
    HIRANO, H
    NISHIMURA, T
    IWAMURA, T
    ANALYTICAL BIOCHEMISTRY, 1985, 150 (01) : 228 - 234
  • [3] An electromagnetically actuated high frequency oscillation pump
    Leati, E.
    Poltschak, F.
    Scheidl, R.
    MECHATRONICS, 2017, 47 : 233 - 245
  • [4] Development of a Paper-Based Microfluidic System for a Continuous High-Flow-Rate Fluid Manipulation
    Naseri, Mahdi
    Simon, George P.
    Batchelor, Warren
    ANALYTICAL CHEMISTRY, 2020, 92 (10) : 7307 - 7316
  • [5] Moving toward high-flow-rate intelligent wells
    Constantine, Jesse
    JPT, Journal of Petroleum Technology, 2007, 59 (11):
  • [6] A hydrogel-driven microfluidic suction pump with a high flow rate
    Seo, Jaedeok
    Wang, Cong
    Chang, Sooyoung
    Park, Jungyul
    Kim, Wonjung
    LAB ON A CHIP, 2019, 19 (10) : 1790 - 1796
  • [7] A micro-cam actuated linear peristaltic pump for microfluidic applications
    Xiang, Jiwen
    Cai, Ziliang
    Zhang, Yong
    Wang, Wanjun
    SENSORS AND ACTUATORS A-PHYSICAL, 2016, 251 : 20 - 25
  • [8] Micromachined silicon cantilever paddle for high-flow-rate sensing
    Ma, Rong-Hua
    Ho, Ming-Chin
    Lee, Chia-Yen
    Wang, Yu-Hsiang
    Fu, Lung-Ming
    SENSORS AND MATERIALS, 2006, 18 (08) : 405 - 417
  • [9] HIGH-FLOW-RATE ARTERIOVENOUS MALFORMATION MODEL FOR SIMULATED THERAPEUTIC EMBOLIZATION
    BARTYNSKI, WS
    OREILLY, GV
    FORREST, MD
    RADIOLOGY, 1988, 167 (02) : 419 - 421
  • [10] Reciprocating flow-assisted nucleic acid purification using a finger-actuated microfluidic device
    Park, Juhwan
    Han, Dong Hyun
    Hwang, Sang-Hyun
    Park, Je-Kyun
    LAB ON A CHIP, 2020, 20 (18) : 3346 - 3353