Optimisation of ultrasound-assisted emulsification microextraction method with solidification of floating organic drop for the analysis of cork taint responsible compounds in wine

被引:12
|
作者
Pizarro, C. [1 ]
Saenz-Gonzalez, C. [1 ]
Perez-del-Notario, N. [1 ]
Gonzalez-Saiz, J. M. [1 ]
机构
[1] Univ La Rioja, Dept Chem, Logrono 26006, La Rioja, Spain
关键词
Ultrasound-assisted emulsification-microextraction; Solidification of floating organic drop; Haloanisoles; Halophenols; Wine; Experimental design; SOLID-PHASE MICROEXTRACTION; CHROMATOGRAPHY-MASS SPECTROMETRY; LIQUID-LIQUID MICROEXTRACTION; ATOMIC-EMISSION DETECTION; BAR SORPTIVE EXTRACTION; GAS-CHROMATOGRAPHY; RED WINE; CHLOROPHENOLS; HALOANISOLES; 2,4,6-TRICHLOROANISOLE;
D O I
10.1016/j.chroma.2012.05.100
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper presents the optimisation of a method based on ultrasound assisted-emulsification method (USAEME) combined with solidification of floating organic drop (SFOD) for the sensitive determination of cork taint responsible compounds in wine. Haloanisoles (2,4,6-trichloranisole (TCA), 2,3,4,6-tetrachloroanisole (TeCA), 2,4,6-tribromoanisole (TBA) and pentachloranisole (PCA)) and their halophenolic precursors were determined by gas chromatography with electron capture detection (GC-ECD). The derivatisation of the halophenols was performed simultaneously with the extraction. To perform the optimisation, the main parameters affecting both extraction and derivatisation were exhaustively studied in different steps. Once the extraction solvent and the pH and time conditions had been determined, experimental design was applied for the simultaneous study of the volumes of acetic anhydride and extraction solvent, temperature and ionic strength conditions. Then, the analytical characteristics of the optimised method were evaluated achieving satisfactory linearity (with correlation coefficients over 0.984), repeatability (below 10.7%) and inter-day precision (below 10.6%) for all target analytes. Moreover, detection limits found were similar or even lower than the olfactory threshold of the studied compounds. Finally, the applicability of the proposed method was tested by analysing real wine samples. To the best of our knowledge, this is the first time that USAEME-SFOD method has been used to determine cork taint responsible compounds in wine. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:60 / 66
页数:7
相关论文
共 50 条
  • [1] Simultaneous determination of cork taint and Brett character responsible compounds in wine using ultrasound-assisted emulsification microextraction with solidification of floating organic drop
    Pizarro, C.
    Saenz-Gonzalez, C.
    Perez-del-Notario, N.
    Gonzalez-Saiz, J. M.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2012, 1249 : 54 - 61
  • [2] Development of an ultrasound-assisted emulsification-microextraction method for the determination of the main compounds causing cork taint in wines
    Pizarro, C.
    Saenz-Gonzalez, Cristina
    Perez-del-Notario, Nuria
    Maria Gonzalez-Saiz, Jose
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2012, 1229 : 63 - 71
  • [3] Ultrasound-assisted emulsification solidified floating organic drop microextraction for the determination of trace amounts of copper in water samples
    Chang, Qingyun
    Zhang, Jingwen
    Du, Xin
    Ma, Jingjun
    Li, Jingci
    [J]. FRONTIERS OF ENVIRONMENTAL SCIENCE & ENGINEERING IN CHINA, 2010, 4 (02): : 187 - 195
  • [4] Ultrasound-assisted emulsification solidified floating organic drop microextraction for the determination of trace amounts of copper in water samples
    Qingyun Chang
    Jingwen Zhang
    Xin Du
    Jingjun Ma
    Jingci Li
    [J]. Frontiers of Environmental Science & Engineering in China, 2010, 4 : 187 - 195
  • [5] Ultrasound-Assisted Emulsification Microextraction Based on Solidification Floating Organic Drop Trace Amounts of Manganese Prior to Graphite Furnace Atomic Absorption Spectrometry Determination
    Mohadesi, Alireza
    Falahnejad, Masoumeh
    [J]. SCIENTIFIC WORLD JOURNAL, 2012,
  • [6] Development of ultrasound-assisted emulsification microextraction based on solidification of a floating organic droplet for determination of organochlorine pesticides in water samples
    Shu, Bin
    Yang, Zhaoguang
    Lee, Hsiaowan
    Qiu, Bo
    Li, Haipu
    [J]. JOURNAL OF SEPARATION SCIENCE, 2016, 39 (04) : 776 - 783
  • [7] Ultrasound-assisted emulsification microextraction for the sensitive determination of Brett character responsible compounds in wines
    Pizarro, C.
    Saenz-Gonzalez, C.
    Perez-del-Notario, N.
    Gonzalez-Saiz, J. M.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (50) : 8975 - 8981
  • [8] Optimisation of a sensitive method based on ultrasound-assisted emulsification-microextraction for the simultaneous determination of haloanisoles and volatile phenols in wine
    Pizarro, Consuelo
    Saenz-Gonzalez, Cristina
    Perez-del-Notario, Nuria
    Maria Gonzalez-Saiz, Jose
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2012, 1244 : 37 - 45
  • [9] Development of an Ultrasound-Assisted Emulsification Microextraction Method for the Determination of Volatile Compounds in Wines
    Chalvantzi, Ioanna
    Nisiotou, Aspasia
    Banilas, Georgios
    Mallouchos, Athanasios
    [J]. SEPARATIONS, 2023, 10 (10)
  • [10] Ultrasound-assisted emulsification microextraction based on solidification of floating organic droplet combined with HPLC-UV for the analysis of antidepressant drugs in biological samples
    Ebrahimzadeh, Homeira
    Saharkhiz, Zahra
    Tavassoli, Marya
    Kamarei, Fahimeh
    Asgharinezhad, Ali Akbar
    [J]. JOURNAL OF SEPARATION SCIENCE, 2011, 34 (11) : 1275 - 1282