Diagnostic accuracy of multidetector computed tomography in the detection of left atrial/left atrial appendage thrombus: a meta-analysis

被引:3
|
作者
Ning, Z. [1 ]
Min, Z. -G. [3 ]
Jiang, H. -X. [1 ]
Hu, B. -L. [2 ]
机构
[1] Guangxi Med Univ, Affiliated Hosp 1, Nanning 530021, Peoples R China
[2] Guangxi Med Informat Inst, Nanning, Peoples R China
[3] Xi An Jiao Tong Univ, Coll Med, Dept Radiol, Xian 710049, Peoples R China
关键词
left atrial; left atrial appendage thrombus; multidetector computed tomography; meta-analysis; PULMONARY VEIN ISOLATION; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; SYSTEMATIC REVIEWS; FILLING DEFECTS; CARDIAC CT; ROW CT; FIBRILLATION; ANGIOGRAPHY; HETEROGENEITY; STROKE;
D O I
10.1111/j.1445-5994.2012.02932.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and objective The current results on the diagnostic accuracy of multidetector computed tomography (MDCT) in the detection of left atrial/left atrial appendage (LA/LAA) thrombus are conflicting. Aim The aim of the present study was to determine the diagnostic accuracy of MDCT in LA/LAA thrombus with meta-analysis. Methods We searched for studies in PubMed, Embase and Cochrane library prior to May 2012 evaluating the accuracy of MDCT in detecting LA/LAA thrombus. Primary results were summarised using a random-effects model or a fixed-effects model. Receiver operating characteristic curves were used to summarise overall diagnosis accuracy. Metaregression and subgroup analysis were used to explore the potential sources of heterogeneity. Results A total of 10 studies with 1313 subjects was included in this meta-analysis. The summary estimates of sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio and the area under cure of overall analysis were 0.84, 0.93, 9.32, 0.21, 50.84 and 0.951, respectively, but all with significant heterogeneity (P < 0.01). Meta-regression and subgroup analysis showed that using electrocardiogram (ECG)-gating technique was a source of heterogeneity (P = 0.022); studies using ECG-gating technique had a higher summary sensitivity than studies with non-gating technique (0.97 vs 0.33). Conclusion Our results suggest that MDCT is a potentially useful technique in the diagnosis of LA/LAA thrombus, especially when ECG gating is applied.
引用
收藏
页码:573 / 580
页数:8
相关论文
共 50 条
  • [1] Multidetector computed tomography for detecting left atrial/left atrial appendage thrombus: a meta-analysis
    Zou, H.
    Zhang, Y.
    Tong, J.
    Liu, Z.
    [J]. INTERNAL MEDICINE JOURNAL, 2015, 45 (10) : 1044 - 1053
  • [2] Detection of Left Atrial Appendage Thrombus by Cardiac Computed Tomography in Patients With Atrial Fibrillation A Meta-Analysis
    Romero, Jorge
    Husain, Syed Arman
    Kelesidis, Iosif
    Sanz, Javier
    Medina, Hector M.
    Garcia, Mario J.
    [J]. CIRCULATION-CARDIOVASCULAR IMAGING, 2013, 6 (02) : 185 - 194
  • [3] Diagnostic Accuracy of Left Atrial/Left Atrial Appendage Thrombus in Patients with Atrial Fibrillation: A Systematic Review and Network Meta-Analysis
    Song, Ruirui
    Liu, Fang
    Shi, Xiaojing
    Gao, Hongmei
    Chen, Jun
    Guo, Xuefeng
    Huang, Jian
    [J]. REVIEWS IN CARDIOVASCULAR MEDICINE, 2023, 24 (11)
  • [4] Multidetector computed tomography for the detection of left atrial appendage thrombus: A comparative study with transesophageal echocardiography
    Shapiro, Michael D.
    Neilan, Tomas G.
    Jassal, Davinder S.
    Samy, Bharat
    Nasir, Khurram
    Hoffmann, Udo
    Sarwar, Ammar
    Butler, Javed
    Brady, Thomas J.
    Cury, Ricardo C.
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2007, 31 (06) : 905 - 909
  • [5] Computed tomography for detecting left atrial thrombus: a meta-analysis
    Wu, Xiaosan
    Wang, Congxia
    Zhang, Chunyan
    Zhang, Yan
    Ding, Faming
    Yan, Jiaojuan
    [J]. ARCHIVES OF MEDICAL SCIENCE, 2012, 8 (06) : 943 - 951
  • [6] Cardiac Computed Tomography versus Transesophageal Echography for the Detection of Left Atrial Appendage Thrombus: A Systemic Review and Meta-Analysis
    Yu, Shandong
    Li, Hongwei
    [J]. CIRCULATION, 2021, 144
  • [7] Cardiac Computed Tomography Versus Transesophageal Echocardiography for the Detection of Left Atrial Appendage Thrombus: A Systemic Review and Meta-Analysis
    Yu, Shandong
    Zhang, Heping
    Li, Hongwei
    [J]. JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2021, 10 (23):
  • [8] Detection of left atrial appendage thrombus by cardiac computed tomography with left prone position imaging
    Sun, Yu
    Xiao, Junrui
    Hou, Jie
    Li, Xiaogang
    Yang, Benqiang
    [J]. BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2019, 125 : 13 - 13
  • [9] Detection of Left Atrial Appendage Thrombus by Cardiac Computed Tomography A Word of Caution
    Garcia, Mario J.
    [J]. JACC-CARDIOVASCULAR IMAGING, 2009, 2 (01) : 77 - 79
  • [10] Multidetector computed tomography evaluation prior to catheter ablation of atrial fibrillation: ruling out left atrial appendage thrombus
    Sousa, P. J.
    Goncalves, P. A.
    Marques, H.
    Carmo, P.
    Brito, J.
    Cale, R.
    Cabrita, D.
    Cavaco, D. M.
    Adragao, P.
    [J]. EUROPEAN HEART JOURNAL, 2010, 31 : 706 - 707