Determination of radon exhalation from construction materials using VOC emission test chambers

被引:10
|
作者
Richter, M. [1 ]
Jann, O. [1 ]
Kemski, J. [2 ]
Schneider, U. [1 ]
Krocker, C. [1 ]
Hoffmann, B. [3 ,4 ]
机构
[1] BAM Fed Inst Mat Res & Testing, Div Mat & Air Pollutants 4 2, D-12203 Berlin, Germany
[2] Kemski & Partner, Bonn, Germany
[3] Fed Off Radiat Protect BfS, Sect SW Radon 1 1, Berlin, Germany
[4] Fed Off Radiat Protect BfS, Sect SW NORM Radioact Residues 1 2, Berlin, Germany
关键词
Radon exhalation; Radon measurement; Building material; Emission test chamber; Indoor Air Quality; Real room radon concentrations; BUILDING-MATERIALS; FLOOR COVERINGS; LUNG-CANCER; RISK;
D O I
10.1111/ina.12031
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Abstract The inhalation of Rn-222 (radon) decay products is one of the most important reasons for lung cancer after smoking. Stony building materials are an important source of indoor radon. This article describes the determination of the exhalation rate of stony construction materials by the use of commercially available measuring devices in combination with VOC emission test chambers. Five materials - two types of clay brick, clinker brick, light-weight concrete brick, and honeycomb brick - generally used for wall constructions were used for the experiments. Their contribution to real room concentrations was estimated by applying room model parameters given in ISO 16000-9, RP 112, and AgBB. This knowledge can be relevant, if for instance indoor radon concentration is limited by law. The test set-up used here is well suited for application in test laboratories dealing with VOC emission testing.
引用
收藏
页码:397 / 405
页数:9
相关论文
共 50 条
  • [1] Robustness validation of a test procedure for the determination of the radon-222 exhalation rate from construction products in VOC emission test chambers
    Hofmann, Michael
    Richter, Matthias
    Jann, Oliver
    APPLIED RADIATION AND ISOTOPES, 2020, 166 (166)
  • [2] Uniformity in radon exhalation from construction materials using can technique
    El-Amria, EA
    Al-Jarallah, MI
    Abu-Jarad, F
    Faza-ur-Rehman
    RADIATION MEASUREMENTS, 2003, 36 (1-6) : 453 - 456
  • [3] USE OF COMMERCIAL RADON MONITORS FOR LOW LEVEL RADON MEASUREMENTS IN DYNAMICALLY OPERATED VOC EMISSION TEST CHAMBERS
    Hofmann, M.
    Richter, M.
    Jann, O.
    RADIATION PROTECTION DOSIMETRY, 2017, 177 (1-2) : 16 - 20
  • [4] Development of a test method using a VOC analyzer to measure VOC emission from adhesives for building materials
    Kim, Sumin
    Kim, Jin-A
    An, Jae-Yoon
    Kim, Hyun-Joong
    Moon, Suck-Joong
    Journal of Adhesion Science and Technology, 2006, 20 (15): : 1783 - 1799
  • [5] Development of a test method using a VOC analyzer to measure VOC emission from adhesives for building materials
    Kim, Sumin
    Kim, Jin-A
    An, Jae-Yoon
    Kim, Hyun-Joong
    Moon, Suck-Joong
    JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 2006, 20 (15) : 1783 - 1799
  • [6] Measurement of radon exhalation rates from some building materials used in Serbian construction
    Stajic, J. M.
    Nikezic, D.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2015, 303 (03) : 1943 - 1947
  • [7] Measurement of radon exhalation rates from some building materials used in Serbian construction
    J. M. Stajic
    D. Nikezic
    Journal of Radioanalytical and Nuclear Chemistry, 2015, 303 : 1943 - 1947
  • [8] RADON EXHALATION FROM BUILDING MATERIALS USED IN YEMEN
    Al Mugahed, Murad
    Bentayeb, Farida
    RADIATION PROTECTION DOSIMETRY, 2018, 182 (04) : 405 - 412
  • [9] Mechanisms of radon exhalation from hardening cementitious materials
    Kovler, Konstantin
    ACI MATERIALS JOURNAL, 2008, 105 (04) : 404 - 413
  • [10] Radon exhalation from building materials for decorative use
    Chen, Jing
    Rahman, Naureen M.
    Abu Atiya, Ibrahim
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2010, 101 (04) : 317 - 322