Improved assessment of pathological regurgitation in patients with prosthetic heart valves by multiplane transesophageal echocardiography

被引:13
|
作者
Kupferwasser, I [1 ]
MohrKahaly, S [1 ]
Erbel, R [1 ]
Nolting, A [1 ]
Dohmen, G [1 ]
Oelert, H [1 ]
Meyer, J [1 ]
机构
[1] UNIV MAINZ,MED CLIN 2,D-6500 MAINZ,GERMANY
关键词
multiplane transesophageal echocardiography; prosthetic heart valves; perivalvular leakages; prosthetic dysfunction;
D O I
10.1111/j.1540-8175.1997.tb00736.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to evaluate the diagnostic increment of individually optimized axes in the assessment of pathological prosthetic valve regurgitation. Forty-two patients with pathologically regurgitant prostheses in the aortic (n = 21), mitral (n = 15), and tricuspid (n = 6) positions were examined by multiplane transesophageal echocardiography. The investigation was performed utilizing the transverse axis first, the longitudinal axis second, and the intermediate axes afterwards. The presence of regurgitation, the differentiation. between trans- and perivalvular origin, and the Localization of perivalvular leakages at the sewing ring were evaluated. Findings in the biplane and intermediate axes were compared to surgery or autopsy in all patients. There was slightly higher detection rate for aortic prosthetic regurgitation using the intermediate axes than the biplane axes. The intermediate axes revealed significantly fewer differences to the morphological control than the biplane axes with regard to the differentiation of peri- and transprosthetic aortic regurgitation and to the localization of a periprosthetic aortic regurgitant origin. The intermediate axes provided significantly better agreement to surgery/autopsy than the biplane axes regarding the localization of the origin of mitral periprosthetic regurgitation. Morphological visualization of the perivaluular gap adds important information on the precise localization of the regurgitant origin. The pathological gap was visualized significantly more often using the intermediate than the biplane axes in all types of prostheses. The data in this study therefore suggest that multiplane transesophageal echocardiography is superior to biplane transesophageal echocardiography in the assessment of pathologic prosthetic regurgitation.
引用
下载
收藏
页码:363 / 373
页数:11
相关论文
共 50 条
  • [1] IMPROVED EVALUATION OF PROSTHETIC VALVE REGURGITATION BY MULTIPLANE TRANSESOPHAGEAL ECHOCARDIOGRAPHY
    FLACHSKAMPF, FA
    SCHONDUBE, FA
    HOFFMANN, R
    FRANKE, A
    JOB, FP
    MESSMER, BJ
    HANRATH, P
    ZEITSCHRIFT FUR KARDIOLOGIE, 1995, 84 (05): : 404 - 410
  • [2] Echocardiography and doppler assessment of prosthetic heart valves with transesophageal echocardiography
    MacKenzie, GS
    Heinle, SK
    CRITICAL CARE CLINICS, 1996, 12 (02) : 383 - &
  • [3] Usefulness of multiplane transesophageal echocardiography to improve the assessment of severity of mitral regurgitation
    Pieper, EPG
    Hamer, HPM
    Sluijs, RAP
    Ravelli, ACJ
    Tijssen, JGP
    Crijns, HJGM
    Lie, KI
    Visser, CA
    AMERICAN JOURNAL OF CARDIOLOGY, 1996, 78 (10): : 1132 - 1139
  • [4] Evaluation of Prosthetic Heart Valves by Transesophageal Echocardiography: Problems, Pitfalls, and Timing of Echocardiography
    Van den Brink, Renee B. A.
    SEMINARS IN CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2006, 10 (01) : 89 - 100
  • [5] TRANSESOPHAGEAL ECHOCARDIOGRAPHY MICROBUBBLES WITH PROSTHETIC VALVES
    GLEN, SK
    WILSON, ES
    GROSSET, DG
    AMERICAN HEART JOURNAL, 1995, 130 (06) : 1312 - 1312
  • [6] TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN PATIENTS WITH PROSTHETIC HEART-VALVES AND SYSTEMIC EMBOLI - IS IT A USEFUL INVESTIGATION
    ELLIS, CJ
    WAITE, ST
    COVERDALE, HA
    JAFFE, WM
    NEW ZEALAND MEDICAL JOURNAL, 1995, 108 (1008) : 376 - 377
  • [7] Characterization of normal leakage flow of monostrut tilting disk prosthetic mitral valves by multiplane transesophageal echocardiography
    Temesvari, A
    Mohl, W
    Kupilik, N
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1997, 10 (02) : 155 - 158
  • [8] EARLY DETECTION OF DYSFUNCTIONS OF PROSTHETIC HEART-VALVES BY TRANSESOPHAGEAL ECHOCARDIOGRAPHY
    MOHRKAHALY, S
    ERBEL, R
    SZYDLOWSKY, D
    MEYER, J
    ZEITSCHRIFT FUR KARDIOLOGIE, 1986, 75 : 55 - 55
  • [9] Real Time Three-dimensional Transesophageal Echocardiography: A Novel Approach for the Assessment of Prosthetic Heart Valves
    Anwar, Ashraf M.
    Nosir, Youssef F. M.
    Alasnag, Mirvat
    Chamsi-Pasha, Hassan
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2014, 31 (02): : 188 - 196
  • [10] CHEMOPROPHYLAXIS BEFORE TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN PATIENTS WITH PROSTHETIC OR BIOPROSTHETIC CARDIAC VALVES
    GAL, RA
    GAECKLE, TC
    GADASALLI, S
    KUBOTA, JM
    ROBBINS, WG
    SCHMIDT, DH
    AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (01): : 115 - 117