Experimental investigation on the measurement deviations in recording brush discharges from insulating surfaces by Coulombmeters

被引:3
|
作者
Chowdhury, Kanchan [1 ,2 ]
von Pidoll, Ulrich [1 ]
机构
[1] Phys Tech Bundesanstalt, D-38116 Braunschweig, Germany
[2] Indian Inst Technol, Cryogen Engn Ctr, Kharagpur 721302, W Bengal, India
关键词
Brush discharge; Insulating surface; Earthed sphere; Coulombmeter; Induced charge; Measurement underestimation; CHARGE-TRANSFER; ELECTROSTATIC DISCHARGES; ESD;
D O I
10.1016/j.elstat.2012.04.005
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The total charge on a charged sheet before and after a provoked brush discharge, their difference "C', the induced charge "A" on different probes immediately before the discharge and their transferred charge "B" measured by commercially available Coulombmeters have been measured for probes from 2 mm to 25 mm in diameter including human thumb and shielded probe. The brush discharges were provoked on PTFE discs 10 cm-20 cm. The results obtained can be used for correct estimation of the incendivity of brush discharges between 10 nC and 90 nC. (c) 2012 Elsevier B.V. All rights reserved.