Panitumumab-IRDye800CW for Fluorescence-Guided Surgical Resection of Colorectal Cancer

被引:21
|
作者
Marston, John C. [1 ,2 ]
Kennedy, Gregory D. [3 ]
Lapi, Suzanne E. [4 ]
Hartman, Yolanda E. [5 ]
Richardson, Morgan T. [5 ]
Modi, Himani M. [5 ]
Warram, Jason M. [4 ,5 ,6 ]
机构
[1] Univ Alabama Birmingham, Sch Med, Dept Surg, Birmingham, AL 35294 USA
[2] Louisiana State Univ, Dept Surg, Hlth Sci Ctr, Baton Rouge, LA USA
[3] Univ Alabama Birmingham, Dept Surg, Volker Hall,G082 1670 Univ Blvd, Birmingham, AL 35294 USA
[4] Univ Alabama Birmingham, Dept Radiol, Volker Hall,G082 1670 Univ Blvd, Birmingham, AL 35294 USA
[5] Univ Alabama Birmingham, Dept Otolaryngol, Volker Hall,G082 1670 Univ Blvd, Birmingham, AL 35294 USA
[6] Univ Alabama Birmingham, Dept Biomed Engn, Volker Hall,G082 1670 Univ Blvd, Birmingham, AL 35294 USA
基金
美国国家卫生研究院;
关键词
Colorectal cancer; Fluorescence-guided surgery; Panitumumab; IRDye800CW; Oncology; Gastrointestinal surgery; Cancer surgery; Epidermal growth factor receptor; CARCINOEMBRYONIC ANTIGEN; COLON-CANCER; ANTIBODY; SURGERY; SGM-101; CEA;
D O I
10.1016/j.jss.2019.01.065
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Fluorescence-guided surgery (FGS) is a rapidly advancing field that may improve outcomes in several cancer types. Although screening has decreased colorectal cancer (CRC) mortality, it remains a common and often fatal malignancy. In this study, we sought to identify an optical imaging agent for the application of FGS technology to CRC. Methods: We compared a panitumumab-IRDye800CW conjugate to an IgG-IRDye800CW isotype control. Mice were implanted with one of three CRC cell lines (LS174T, Colo205, and SW948) and imaged with open- and closed-filed fluorescence imaging systems. Fluorescent contrast was quantified by calculating the ratio between tumor and background fluorescence. After 10 d, the mice were sacrificed, and their tumors stained for microscopic imaging. Results: Panitumumab-IRDye800CW produced significantly greater (P < 0.05) fluorescent contrast in all three cell lines. Average tumor to background ratio was 6.00 versus 2.60 for LS174T, 5.78 versus 2.52 for Colo205, and 4.31 versus 1.70 for SW948. A 1-mg tumor fragment produced significantly greater fluorescent contrast in the Colo205 and SW948 cell lines in the panitumumab-IRDye800CW group. Western blotting for epidermal growth factor receptor (EGFR) and a semiquantitative analysis of EGFR expression noted strong expression in all three cell lines; however, EGFR expression did not directly correlate to tumor to background ratio. Conclusions: Panitumumab-IRDye800CW produces significantly greater fluorescent contrast than IgG-IRDye800CW in a murine model of CRC and is a suitable agent for the application of FGS technology to CRC. (C) 2019 Elsevier Inc. All rights reserved.
引用
收藏
页码:44 / 51
页数:8
相关论文
共 50 条
  • [1] PANITUMUMAB-IRDYE800CW FOR FLUORESCENCE-GUIDED SURGICAL RESECTION OF COLORECTAL CANCER
    Marston, John C.
    Hartman, Yolanda E.
    Warram, Jason M.
    Kennedy, Gregory D.
    GASTROENTEROLOGY, 2018, 154 (06) : S1288 - S1288
  • [2] Safety of panitumumab-IRDye800CW and cetuximab-IRDye800CW for fluorescence-guided surgical navigation in head and neck cancers
    Gao, Rebecca W.
    Teraphongphom, Nutte
    de Boer, Esther
    van den Berg, Nynke S.
    Divi, Vasu
    Kaplan, Michael J.
    Oberhelman, Nicholas J.
    Hong, Steven S.
    Capes, Elissa
    Colevas, A. Dimitrios
    Warram, Jason M.
    Rosenthal, Eben L.
    THERANOSTICS, 2018, 8 (09): : 2488 - 2495
  • [3] Optimal Dosing Strategy for Fluorescence-Guided Surgery with Panitumumab-IRDye800CW in Head and Neck Cancer
    Naoki Nishio
    Nynke S. van den Berg
    Stan van Keulen
    Brock A. Martin
    Shayan Fakurnejad
    Quan Zhou
    Guolan Lu
    Stefania U. Chirita
    Michael J. Kaplan
    Vasu Divi
    Alexander D. Colevas
    Eben L. Rosenthal
    Molecular Imaging and Biology, 2020, 22 : 156 - 164
  • [4] Optimal Dosing Strategy for Fluorescence-Guided Surgery with Panitumumab-IRDye800CW in Head and Neck Cancer
    Nishio, Naoki
    van den Berg, Nynke S.
    van Keulen, Stan
    Martin, Brock A.
    Fakurnejad, Shayan
    Zhou, Quan
    Lu, Guolan
    Chirita, Stefania U.
    Kaplan, Michael J.
    Divi, Vasu
    Colevas, Alexander D.
    Rosenthal, Eben L.
    MOLECULAR IMAGING AND BIOLOGY, 2020, 22 (01) : 156 - 164
  • [5] Fluorescence-guided resection of experimental malignant glioma using cetuximab-IRDye 800CW
    Warram, Jason M.
    de Boer, Esther
    Korb, Melissa
    Hartman, Yolanda
    Kovar, Joy
    Markert, James M.
    Gillespie, G. Yancey
    Rosenthal, Eben L.
    BRITISH JOURNAL OF NEUROSURGERY, 2015, 29 (06) : 850 - 858
  • [6] Feasibility of bevacizumab-IRDye800CW as a tracer for fluorescence-guided meningioma surgery
    Dijkstra, Bianca M.
    Nonnekens, Julie
    Nagengast, Wouter
    Kruijff, Schelto
    Meersma, Gert Jan
    Dunnen, Wilfred F. A. den
    Kruyt, Frank A. E.
    Groen, Rob J. M.
    JOURNAL OF NEUROSURGERY, 2023, 138 (05) : 1263 - 1272
  • [7] Metastatic and sentinel lymph node mapping using intravenously delivered Panitumumab-IRDye800CW
    Krishnan, Giri
    van den Berg, Nynke S.
    Nishio, Naoki
    Juniper, Georgina
    Pei, Jaqueline
    Zhou, Quan
    Lu, Guolan
    Lee, Yu-Jin
    Ramos, Kimberly
    Iagaru, Andrei H.
    Baik, Fred M.
    Colevas, Alexander D.
    Martin, Brock A.
    Rosenthal, Eben L.
    THERANOSTICS, 2021, 11 (15): : 7188 - 7198
  • [8] The Use of Panitumumab-IRDye800CW in a Novel Murine Model for Conjunctival Squamous Cell Carcinoma
    Youn, Gun Min
    Case, Ayden G.
    Jarin, Trent
    Li, BaoXiang
    Swarup, Aditi
    Naranjo, Andrea
    Bou-Khalil, Charbel
    Yao, Jacqueline
    Zhou, Quan
    Hom, Marisa E.
    Rosenthal, Eben L.
    Wu, Albert Y.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2022, 11 (07):
  • [9] Tumour-specific fluorescence-guided surgery for pancreatic cancer using panitumumab-IRDye800CW: a phase 1 single-centre, open-label, single-arm, dose-escalation study
    Lu, Guolan
    van den Berg, Nynke S.
    Martin, Brock A.
    Nishio, Naoki
    Hart, Zachary P.
    van Keulen, Stan
    Fakurnejad, Shayan
    Chirita, Stefania U.
    Raymundo, Roan C.
    Yi, Grace
    Zhou, Quan
    Fisher, George A.
    Rosenthal, Eben L.
    Poultsides, George A.
    LANCET GASTROENTEROLOGY & HEPATOLOGY, 2020, 5 (08): : 753 - 764
  • [10] Anti-GD2-IRDye800CW as a targeted probe for fluorescence-guided surgery in neuroblastoma
    Wellens, Lianne M.
    Deken, Marion M.
    Sier, Cornelis F. M.
    Johnson, Hannah R.
    Ortiz, Fatima de la Jara
    Bhairosingh, Shadhvi S.
    Houvast, Ruben D.
    Kholosy, Waleed M.
    Baart, Victor M.
    Pieters, Annique M. M. J.
    de Krijger, Ronald R.
    Molenaar, Jan J.
    Wehrens, Ellen J.
    Dekkers, Johanna F.
    Wijnen, Marc H. W. A.
    Vahrmeijer, Alexander L.
    Rios, Anne C.
    SCIENTIFIC REPORTS, 2020, 10 (01)