Primary Clinical Application of Y-Shaped Jogged Stent Implantation in Patients with Malignant Hilar Biliary Obstruction

被引:2
|
作者
Zhao, Zhongwei [1 ,2 ]
Song, Jingjing [1 ,2 ]
Fan, Xiaoxi [1 ,2 ]
Fang, Shiji [1 ,2 ]
Chen, Minjiang [1 ,2 ]
Chen, Weiqian [1 ,2 ]
Wu, Fazong [1 ,2 ]
Zheng, Liyun [1 ,2 ]
Tu, Jianfei [1 ,2 ]
Ji, Jiansong [1 ,2 ]
机构
[1] Lishui Cent Hosp, Key Lab Imaging Diag & Minimally Invas Intervent, Lishui 323000, Zhejiang, Peoples R China
[2] Wenzhou Med Univ, Lishui Cent Hosp, Affiliated Hosp 5, Dept Intervent Radiol,Zhejiang Univ,Lishui Hosp, 289 Kuocang Rd, Lishui 323000, Zhejiang, Peoples R China
关键词
Y-shaped jogged stent; Malignant hilar biliary obstruction; Retrospectively; Stent patency time; Survival time; METALLIC STENTS; MANAGEMENT; DRAINAGE; PALLIATION; INSERTION; STENOSIS;
D O I
10.1007/s11605-019-04131-1
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
ObjectiveTo assess the feasibility, safety, and efficacy of Y-shaped jogged stent in patients with malignant hilar biliary obstruction.MethodsA total of 196 patients with malignant hilar biliary obstruction treated by biliary tract stent implantation from August 2010 to August 2017 were retrospectively reviewed. Seventeen consecutive patients who were treated with Y-shaped jogged stent implantation were identified as the Y-shaped jogged stent implantation group. Seventeen matched patients undergoing unilateral stent placement combined with percutaneous transhepatic cholangial drainage (PTCD) were enrolled as the control group. Baseline characteristics of patients, stent patency time, and survival time were compared.ResultsThere was no significant difference in the age, gender, tumor type and stage, biliary obstruction classification, bilirubin level at diagnosis, presence of metastasis, or chemotherapy between the Y-stent group and the control group (P>0.05). One week after surgery, the reduction rate of bilirubin was significantly higher in the Y-stent group (88.2% vs 53.0%, P<0.05). The mean stent patency time was longer in the Y-stent group (7.31.0months vs 5.7 +/- 0.9months, P<0.05). The mean survival time of the Y-stent group (9.1 +/- 1.5months) was longer than the control group (7.2 +/- 1.1months, P>0.05). There was no severe complication occurred in both two groups.Conclusion p id=Par4 Y-shaped jogged stent implantation was a safe, feasible, and effective approach in the treatment of patients with malignant hilar biliary obstruction, with the significantly prolonged stent patency time and survival time.
引用
收藏
页码:745 / 750
页数:6
相关论文
共 50 条
  • [1] Primary Clinical Application of Y-Shaped Jogged Stent Implantation in Patients with Malignant Hilar Biliary Obstruction
    Zhongwei Zhao
    Jingjing Song
    Xiaoxi Fan
    Shiji Fang
    Minjiang Chen
    Weiqian Chen
    Fazong Wu
    Liyun Zheng
    Jianfei Tu
    Jiansong Ji
    Journal of Gastrointestinal Surgery, 2019, 23 : 745 - 750
  • [2] Y-Shaped Endoscopic Bilateral Metal Stent Placement for Malignant Hilar Biliary Obstruction: Efficacy of a Biliary Y-Stent
    Kim, Jin Hong
    Hwang, Jae Chul
    Lee, Yoonchul
    Lim, Sun Gyo
    Yoo, Byung Moo
    GASTROINTESTINAL ENDOSCOPY, 2010, 71 (05) : AB300 - AB301
  • [3] Malignant Hilar Biliary Obstruction: Treatment by Means of Placement of a Newly Designed Y-Shaped Branched Covered Stent
    Jong Hyouk Yun
    Gyoo-Sik Jung
    Jung Gu Park
    Byung Chul Kang
    Dong-Hoon Shin
    Byung Chul Yun
    Sang Uk Lee
    CardioVascular and Interventional Radiology, 2016, 39 : 582 - 590
  • [4] Malignant Hilar Biliary Obstruction: Treatment by Means of Placement of a Newly Designed Y-Shaped Branched Covered Stent
    Yun, Jong Hyouk
    Jung, Gyoo-Sik
    Park, Jung Gu
    Kang, Byung Chul
    Shin, Dong-Hoon
    Yun, Byung Chul
    Lee, Sang Uk
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2016, 39 (04) : 582 - 590
  • [5] Y-SHAPED ENDOPROSTHESIS STENT - A NEW DEVICE FOR BILIARY DRAINAGE IN MALIGNANT OBSTRUCTION
    HAUENSTEIN, KH
    BECK, A
    SONTHEIMER, J
    KRUGER, HJ
    SALM, R
    RADIOLOGE, 1988, 28 (05): : 243 - 246
  • [6] Y-shaped endoscopic bilateral metal stent placement for malignant hilar biliary obstruction: prospective long-term study
    Hwang, Jae Chul
    Kim, Jin Hong
    Lim, Sun Gyo
    Kim, Soon Sun
    Yoo, Byung Moo
    Cho, Sung Won
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2011, 46 (03) : 326 - 332
  • [7] Y-SHAPED BILATERAL SELF EXPANDABLE METALLIC STENT PLACEMENT FOR MALIGNANT HILAR BILIARY OBSTRUCTION: DATA FROM A LARGE SERIES OF PATIENTS TREATED WITH THE STENT-IN-STENT TECHNIQUE
    Di Mitri, R.
    Mocciaro, F.
    Sferrazza, S.
    DIGESTIVE AND LIVER DISEASE, 2014, 46 : S22 - S22
  • [8] Y-shaped endoscopic bilateral stenting with new wider-mesh biliary stent in malignant hilar obstruction: Long-term results
    Kim, JH
    Yoo, BM
    Choi, JH
    Lee, KM
    Lee, KJ
    Hahm, KB
    Cho, SW
    GASTROINTESTINAL ENDOSCOPY, 2005, 61 (05) : AB193 - AB193
  • [9] A Newly Designed Y-shaped Covered Stent in the Palliative Treatment of Hepatic Hilar Malignant Obstruction: Case Report
    Kang, Byung Chul
    Lee, So Yon
    Chung, Hwan Hoon
    KOREAN JOURNAL OF RADIOLOGY, 2013, 14 (01) : 97 - 101
  • [10] Y-Shaped Bilateral Self-Expandable Metallic Stent Placement for Malignant Hilar Biliary Obstruction: Data from a Referral Center for Palliative Care
    Di Mitri, R.
    Mocciaro, F.
    SCIENTIFIC WORLD JOURNAL, 2014,