机构:
Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
Massachusetts Gen Hosp, Athinoula A Martinos Ctr Biomed Imaging, Boston, MA 02114 USA
Harvard Med Sch, Dept Radiol, Boston, MA 02115 USAStanford Univ, Dept Radiol, Stanford, CA 94305 USA
Chen, Jingyuan E.
[1
,2
,3
]
Polimeni, Jonathan R.
论文数: 0引用数: 0
h-index: 0
机构:
Massachusetts Gen Hosp, Athinoula A Martinos Ctr Biomed Imaging, Boston, MA 02114 USA
Harvard Med Sch, Dept Radiol, Boston, MA 02115 USA
Harvard Massachusetts Inst Technol, Div Hlth Sci & Technol, Cambridge, MA USAStanford Univ, Dept Radiol, Stanford, CA 94305 USA
Polimeni, Jonathan R.
[2
,3
,4
]
Bollmann, Saskia
论文数: 0引用数: 0
h-index: 0
机构:
Univ Queensland, Ctr Adv Imaging, Brisbane, Qld 4072, AustraliaStanford Univ, Dept Radiol, Stanford, CA 94305 USA
Bollmann, Saskia
[5
]
Glover, Gary H.
论文数: 0引用数: 0
h-index: 0
机构:
Stanford Univ, Dept Radiol, Stanford, CA 94305 USAStanford Univ, Dept Radiol, Stanford, CA 94305 USA
Glover, Gary H.
[1
]
机构:
[1] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[2] Massachusetts Gen Hosp, Athinoula A Martinos Ctr Biomed Imaging, Boston, MA 02114 USA
[3] Harvard Med Sch, Dept Radiol, Boston, MA 02115 USA
[4] Harvard Massachusetts Inst Technol, Div Hlth Sci & Technol, Cambridge, MA USA
[5] Univ Queensland, Ctr Adv Imaging, Brisbane, Qld 4072, Australia
Recent advances in parallel imaging and simultaneous multi-slice techniques have permitted whole-brain fMRI acquisitions at sub-second sampling intervals, without significantly sacrificing the spatial coverage and resolution. Apart from probing brain function at finer temporal scales, faster sampling rates may potentially lead to enhanced functional sensitivity, owing possibly to both cleaner neural representations (due to less aliased physiological noise) and additional statistical benefits (due to more degrees of freedom for a fixed scan duration). Accompanying these intriguing aspects of fast acquisitions, however, confusion has also arisen regarding (1) how to preprocess/analyze these fast fMRI data, and (2) what exactly is the extent of benefits with fast acquisitions, i.e., how fast is fast enough for a specific research aim? The first question is motivated by the altered spectral distribution and noise characteristics at short sampling intervals, while the second question seeks to reconcile the complicated trade-offs between the functional contrast-to-noise ratio and the effective degrees of freedom. Although there have been recent efforts to empirically approach different aspects of these two questions, in this work we discuss, from a theoretical perspective accompanied by some illustrative, proof-of-concept experimental in vivo human fMRI data, a few considerations that are rarely mentioned, yet are important for both preprocessing and optimizing statistical inferences for studies that employ acquisitions with sub-second sampling intervals. Several summary recommendations include concerns regarding advisability of relying on low-pass filtering to de-noise physiological contributions, employment of statistical models with sufficient complexity to account for the substantially increased serial correlation, and cautions regarding using rapid sampling to enhance functional sensitivity given that different analysis models may associate with distinct trade-offs between contrast-to-noise ratios and the effective degrees of freedom. As an example, we demonstrate that as TR shortens, the intrinsic differences in how noise is accommodated in general linear models and Pearson correlation analyses (assuming Gaussian distributed stochastic signals and noise) can result in quite different outcomes, either gaining or losing statistical power.
机构:
Catholic Univ Korea, St Vincents Hosp, Dept Family Med, Seoul, South KoreaCatholic Univ Korea, St Vincents Hosp, Dept Family Med, Seoul, South Korea
Song, Sang Wook
Chang, Yoosoo
论文数: 0引用数: 0
h-index: 0
机构:
Kangbuk Samsung Hosp, Hlth Screening Ctr, Seoul, South KoreaCatholic Univ Korea, St Vincents Hosp, Dept Family Med, Seoul, South Korea
Chang, Yoosoo
KOREAN JOURNAL OF FAMILY MEDICINE,
2009,
30
(10):
: 759
-
760