Reproducibility of a non-invasive real-time measure of cardiac parasympathetic activity

被引:11
|
作者
Murray, PG [1 ]
Hamilton, RM [1 ]
Macfarlane, PW [1 ]
机构
[1] Univ Glasgow, Glasgow Royal Infirm, Dept Med Cardiol, Glasgow G31 2ER, Lanark, Scotland
关键词
reproducibility; parasympathetic activity; NeuroScope; autonomic nervous system;
D O I
10.1088/0967-3334/22/4/302
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The NeuroScope is a new device which produces a continuous real-time index of cardiac parasympathetic activity (the CIPA) and accurately measures RR intervals. The reproducibility of the CIPA has not yet been assessed. This study was designed to assess the reproducibility of a 5 minute recording of the CIPA using the NeuroScope and compare it with that of conventional heart rate variability (HRV) measures. 50 subjects (31 male, 19 female) aged 21-77 years were recruited. I I of these were apparently healthy and 39 were patients with a variety of cardiological problems. Two 5 minute recordings of CIPA and RR intervals for each subject were made with a 2-3 minute break between recordings. The limits of agreement for the CIPA were such that the second estimate was between 72 and 140% of the first estimate, 95% of the time. The limits of agreement for other indices of HRV, namely SDNN, rMSSD, In low-frequency HRV and In high-frequency HRV, were 61-157%, 68-153%, 77-131% and 76-133%. The short-term reproducibility of a 5 minute recording of CIPA is moderate and better than simple time-domain but not frequency-domain measures of HRV.
引用
收藏
页码:661 / 672
页数:12
相关论文
共 50 条
  • [1] Reproducibility of a non-invasive real-time measure of cardiac parasympathetic activity in fully conscious human volunteers
    Murray, PG
    Hamilton, RM
    Macfarlane, PW
    JOURNAL OF PHYSIOLOGY-LONDON, 2001, 533 : 76P - 76P
  • [2] REAL-TIME SINGLE BEAT NON-INVASIVE RECORDING OF THE CARDIAC CONDUCTION SYSTEM ACTIVITY
    PALKO, T
    WAJSZCZUK, WJ
    BAULD, TJ
    RUBENFIRE, M
    AMERICAN JOURNAL OF CARDIOLOGY, 1982, 49 (04): : 1030 - 1030
  • [3] Non-invasive real-time measurements of cardiac vagal tone in dogs with cardiac disease
    Little, CJL
    Julu, POO
    Hansen, S
    Reid, SWJ
    VETERINARY RECORD, 2005, 156 (04) : 101 - 105
  • [4] Real-time, non-invasive assessment of human hematocrit
    Duncan, Donald D.
    Fischer, David G.
    Myers, Jerry G.
    DYNAMICS AND FLUCTUATIONS IN BIOMEDICAL PHOTONICS IX, 2012, 8222
  • [5] Real-time Motion Tracking for Non-invasive Ultrasound Cardiac Therapy using Histotripsy
    Miller, Ryan M.
    Kim, Yohan
    Lin, Kuang-Wei
    Owens, Gabe
    Cain, Charles A.
    Xu, Zhen
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 935 - 938
  • [6] NeuroVAD: Real-Time Voice Activity Detection from Non-Invasive Neuromagnetic Signals
    Dash, Debadatta
    Ferrari, Paul
    Dutta, Satwik
    Wang, Jun
    SENSORS, 2020, 20 (08)
  • [7] Real-time non-invasive in vivo imaging of estrogen receptor activity in transgenic mice
    Ciana, P
    Lowik, C
    Vegeto, E
    Brusadelli, A
    Belcredito, S
    Que, I
    Maggi, A
    JOURNAL OF BONE AND MINERAL RESEARCH, 2002, 17 : S217 - S217
  • [8] Microfabricated sensors for non-invasive, real-time monitoring of organoids
    Kim, Yoojeong
    Chica-Carrillo, Erick C.
    Lee, Hyunjoo J.
    MICRO AND NANO SYSTEMS LETTERS, 2024, 12 (01)
  • [9] Photometric sensor system for a non-invasive real-time hemoglobin
    Timm, Ulrich
    Kraitl, Jens
    Schnurstein, Kirstin
    Ewald, Hartmut
    ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC SYSTEMS XI, 2013, 8572
  • [10] Non-invasive assessment of cerebral autoregulation in real-time mode
    Semenyutin, V. B.
    Aliev, V. A.
    Ivankov, A. A.
    Patzak, A.
    Panuntsev, G. K.
    Govorov, B. B.
    Nikiforova, A. A.
    CEREBROVASCULAR DISEASES, 2015, 39 : 46 - 46