Automatic needle tracking using Mask R-CNN for MRI-guided percutaneous interventions

被引:15
|
作者
Li, Xinzhou [1 ,2 ]
Young, Adam S. [1 ]
Raman, Steven S. [1 ]
Lu, David S. [1 ]
Lee, Yu-Hsiu [3 ]
Tsao, Tsu-Chin [3 ]
Wu, Holden H. [1 ,2 ]
机构
[1] Univ Calif Los Angeles, Dept Radiol Sci, 300 UCLA Med Plaza,Suite B119, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, Dept Bioengn, Los Angeles, CA 90095 USA
[3] Univ Calif Los Angeles, Dept Mech & Aerosp Engn, Los Angeles, CA USA
关键词
Interventional MRI; Device tracking; Needle feature; Real-time MRI; Deep learning; Convolutional neural network; LOCALIZATION; BIOPSY; CANCER; STATE;
D O I
10.1007/s11548-020-02226-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose Accurate needle tracking provides essential information for MRI-guided percutaneous interventions. Passive needle tracking using MR images is challenged by variations of the needle-induced signal void feature in different situations. This work aimed to develop an automatic needle tracking algorithm for MRI-guided interventions based on the Mask Region Proposal-Based Convolutional Neural Network (R-CNN). Methods Mask R-CNN was adapted and trained to segment the needle feature using 250 intra-procedural images from 85 MRI-guided prostate biopsy cases and 180 real-time images from MRI-guided needle insertion in ex vivo tissue. The segmentation masks were passed into the needle feature localization algorithm to extract the needle feature tip location and axis orientation. The proposed algorithm was tested using 208 intra-procedural images from 40 MRI-guided prostate biopsy cases, and 3 real-time MRI datasets in ex vivo tissue. The algorithm results were compared with human-annotated references. Results In prostate datasets, the proposed algorithm achieved needle feature tip localization error with median Euclidean distance (dxy) of 0.71 mm and median difference in axis orientation angle (d theta) of 1.28 degrees, respectively. In 3 real-time MRI datasets, the proposed algorithm achieved consistent dynamic needle feature tracking performance with processing time of 75 ms/image: (a) median dxy = 0.90 mm, median d theta = 1.53 degrees; (b) median dxy = 1.31 mm, median d theta = 1.9 degrees; (c) median dxy = 1.09 mm, median d theta = 0.91 degrees. Conclusions The proposed algorithm using Mask R-CNN can accurately track the needle feature tip and axis on MR images from in vivo intra-procedural prostate biopsy cases and ex vivo real-time MRI experiments with a range of different conditions. The algorithm achieved pixel-level tracking accuracy in real time and has potential to assist MRI-guided percutaneous interventions.
引用
收藏
页码:1673 / 1684
页数:12
相关论文
共 50 条
  • [1] Automatic needle tracking using Mask R-CNN for MRI-guided percutaneous interventions
    Xinzhou Li
    Adam S. Young
    Steven S. Raman
    David S. Lu
    Yu-Hsiu Lee
    Tsu-Chin Tsao
    Holden H. Wu
    International Journal of Computer Assisted Radiology and Surgery, 2020, 15 : 1673 - 1684
  • [2] Physics-Driven Mask R-CNN for Physical Needle Localization in MRI-Guided Percutaneous Interventions
    Li, Xinzhou
    Lee, Yu-Hsiu
    Lu, David S.
    Tsao, Tsu-Chin
    Wu, Holden H.
    IEEE ACCESS, 2021, 9 : 161055 - 161068
  • [3] Manually controlled steerable needle for MRI-guided percutaneous interventions
    Henken, Kirsten R.
    Seevinck, Peter R.
    Dankelman, Jenny
    van den Dobbelsteen, John J.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2017, 55 (02) : 235 - 244
  • [4] Manually controlled steerable needle for MRI-guided percutaneous interventions
    Kirsten R. Henken
    Peter R. Seevinck
    Jenny Dankelman
    John J. van den Dobbelsteen
    Medical & Biological Engineering & Computing, 2017, 55 : 235 - 244
  • [5] Automatic Crack Detection using Mask R-CNN
    Attard, Leanne
    Debono, Carl James
    Valentino, Gianluca
    di Castro, Mario
    Masi, Alessandro
    Scibile, Luigi
    PROCEEDINGS OF THE 2019 11TH INTERNATIONAL SYMPOSIUM ON IMAGE AND SIGNAL PROCESSING AND ANALYSIS (ISPA 2019), 2019, : 152 - 157
  • [6] Remotely Actuated Needle Driving Device for MRI-Guided Percutaneous Interventions
    Wu, Di
    Li, Gang
    Patel, Niravkumar
    Yan, Jiawen
    Monfaredi, Reza
    Cleary, Kevin
    Iordachita, Iulian
    2019 INTERNATIONAL SYMPOSIUM ON MEDICAL ROBOTICS (ISMR), 2019,
  • [7] AUTOMATIC SHEEP BEHAVIOUR ANALYSIS USING MASK R-CNN
    Xu, Jingsong
    Wu, Qiang
    Zhang, Jian
    Tait, Amy
    2021 INTERNATIONAL CONFERENCE ON DIGITAL IMAGE COMPUTING: TECHNIQUES AND APPLICATIONS (DICTA 2021), 2021, : 141 - 146
  • [8] Reconfigurable Fiducial-Integrated Modular Needle Driver for MRI-Guided Percutaneous Interventions
    Ji, Wenzhi
    Matte, Joshua D.
    Li, Gang
    Ma, Yunzhao
    Su, Hao
    Shang, Weijian
    Fischer, Gregory S.
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2013, 7 (03):
  • [9] Detection of Green Asparagus Using Improved Mask R-CNN for Automatic Harvesting
    Liu, Xiangpeng
    Wang, Danning
    Li, Yani
    Guan, Xiqiang
    Qin, Chengjin
    SENSORS, 2022, 22 (23)
  • [10] Automatic Velocity Picking Based on Improved Mask R-CNN
    Yuan, Yijun
    Li, Ying
    Fang, Xiaoxuan
    Shi, Fengfeng
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2023, 61 : 1 - 12