共 2 条
RACER-GRASP: Respiratory-weighted, aortic contrast enhancement-guided and coil-unstreaking golden-angle radial sparse MRI
被引:41
|作者:
Feng, Li
[1
]
Huang, Chenchan
Shanbhogue, Krishna
Sodickson, Daniel K.
Chandarana, Hersh
Otazo, Ricardo
机构:
[1] NYU, Sch Med, Dept Radiol, Ctr Adv Imaging Innovat & Res CAI2R, 660 First Ave, New York, NY 10016 USA
关键词:
RACER-GRASP;
coil unstreaking;
radial imaging;
streaking artifact;
free breathing;
compressed sensing;
DCE-MRI;
liver;
STREAK ARTIFACT REDUCTION;
RECONSTRUCTION;
SELECTION;
D O I:
10.1002/mrm.27002
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
PurposeTo develop and evaluate a novel dynamic contrast-enhanced imaging technique called RACER-GRASP (Respiratory-weighted, Aortic Contrast Enhancement-guided and coil-unstReaking Golden-angle RAdial Sparse Parallel) MRI that extends GRASP to include automatic contrast bolus timing, respiratory motion compensation, and coil-weighted unstreaking for improved imaging performance in liver MRI. MethodsIn RACER-GRASP, aortic contrast enhancement (ACE) guided k-space sorting and respiratory-weighted sparse reconstruction are performed using aortic contrast enhancement and respiratory motion signals extracted directly from the acquired data. Coil unstreaking aims to weight multicoil k-space according to streaking artifact level calculated for each individual coil during image reconstruction, so that coil elements containing a high level of streaking artifacts contribute less to the final results. Self-calibrating GRAPPA operator gridding was applied as a pre-reconstruction step to reduce computational burden in the subsequent iterative reconstruction. The RACER-GRASP technique was compared with standard GRASP reconstruction in a group of healthy volunteers and patients referred for clinical liver MR examination. ResultsCompared with standard GRASP, RACER-GRASP significantly improved overall image quality (average score: 3.25 versus 3.85) and hepatic vessel sharpness/clarity (average score: 3.58 versus 4.0), and reduced residual streaking artifact level (average score: 3.23 versus 3.94) in different contrast phases. RACER-GRASP also enabled automatic timing of the arterial phases. ConclusionsThe aortic contrast enhancement-guided sorting, respiratory motion suppression and coil unstreaking introduced by RACER-GRASP improve upon the imaging performance of standard GRASP for free-breathing dynamic contrast-enhanced MRI of the liver. Magn Reson Med 80:77-89, 2018. (c) 2017 International Society for Magnetic Resonance in Medicine.
引用
收藏
页码:77 / 89
页数:13
相关论文