Ventricular Arrhythmias and Implantable Cardioverter-Defibrillator Therapy in Patients With Continuous-Flow Left Ventricular Assist Devices Need for Primary Prevention?

被引:132
|
作者
Garan, Arthur R. [1 ]
Yuzefpolskaya, Melana [1 ]
Colombo, Paolo C. [1 ]
Morrow, John P. [1 ]
Te-Frey, Rosie [2 ]
Dano, Drew [1 ]
Takayama, Hiroo [2 ]
Naka, Yoshifumi [2 ]
Garan, Hasan [1 ]
Jorde, Ulrich P. [1 ]
Uriel, Nir [1 ]
机构
[1] Columbia Univ, Med Ctr, Dept Med, Div Cardiol, New York, NY 10032 USA
[2] Columbia Univ, Med Ctr, Dept Surg, Div Cardiothorac Surg, New York, NY 10032 USA
基金
美国国家卫生研究院;
关键词
heart failure; implantable cardioverter-defibrillator; left ventricular assist device; ventricular arrhythmia; ventricular tachycardia; HEART-FAILURE; FIBRILLATION; SURVIVAL; SUPPORT;
D O I
10.1016/j.jacc.2013.04.020
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives This study sought to evaluate the prevalence and significance of ventricular arrhythmia (VA) and the role of an implantable cardioverter-defibrillator (ICD) in patients supported by a continuous-flow left ventricular assist device (CF-LVAD). Background VAs are common in patients supported by CF-LVADs but prospective data to support the routine use of ICDs in these patients are lacking. Methods All patients supported by long-term CF-LVAD receiving care at our institution were enrolled. The ICDs were interrogated at baseline and throughout prospective follow-up. The VA was defined as ventricular tachycardia/fibrillation lasting >30 s or effectively terminated by appropriate ICD tachytherapy. The primary outcome was the occurrence of VA >30 days after CF-LVAD implantation. Results Ninety-four patients were enrolled; 77 had an ICD and 17 did not. Five patients with an ICD had it deactivated or a depleted battery not replaced during the study. Twenty-two patients had a VA >30 days after LVAD implantation. Pre-operative VA was the major predictor of post-operative arrhythmia. Absence of pre-operative VA conferred a low risk of post-operative VA (4.0% vs. 45.5%; p < 0.001). No patients discharged from the hospital without an ICD after CF-LVAD implantation died during 276.2 months of follow-up (mean time without ICD, 12.7 +/- 12.3 months). Conclusions Patients with pre-operative VA are at risk of recurrent VA while on CF-LVAD support and should have active ICD therapy to minimize sustained VA. Patients without pre-operative VA are at low risk and may not need active ICD therapy. (C) 2013 by the American College of Cardiology Foundation
引用
收藏
页码:2542 / 2550
页数:9
相关论文
共 50 条
  • [1] Implantable Cardioverter-Defibrillator Events in Patients with Left Ventricular Assist Devices
    Ambardekar, Amrut V.
    Sauer, William H.
    Brieke, Andreas
    Lowery, Christopher M.
    Allen, Larry A.
    JOURNAL OF CARDIAC FAILURE, 2009, 15 (06) : S47 - S48
  • [2] Ventricular Arrhythmias in Patients With Continuous-flow Left Ventricular Assist Devices
    Kuten, David
    McLean, Rhondalyn
    Russell, Stuart
    CIRCULATION, 2013, 128 (22)
  • [3] Ventricular arrhythmias in patients with continuous-flow left ventricular assist devices
    Gkouziouta, A. Aggeliki
    Bonios, M.
    Zarkalis, D.
    Adamopoulos, S.
    Kogerakis, N.
    EUROPEAN JOURNAL OF HEART FAILURE, 2019, 21 : 75 - 75
  • [4] Implantable cardioverter-defibrillator therapy in patients with left ventricular assist devices: a shocking tale of survival
    Ho, Gordon
    Wettersten, Nicholas
    Greenberg, Barry
    EUROPEAN JOURNAL OF HEART FAILURE, 2020, 22 (01) : 29 - 31
  • [5] Implantable cardioverter-defibrillator shocks in patients with ventricular assist devices
    Gkouziouta, A.
    Katsianis, A.
    Kostopoulou, A.
    Cokkinos, P. H.
    Karavolias, G.
    Maounis, T. H.
    Livanis, E.
    Theodorakis, G.
    Sfirakis, P.
    Adamopoulos, S.
    EUROPEAN HEART JOURNAL, 2013, 34 : 259 - 260
  • [6] Role of implantable cardioverter-defibrillator in patients awaiting heart transplant in the continuous-flow left ventricular assist device era
    Trivedi, Jaimin R.
    Slaughter, Mark S.
    Pan, Queeny
    Vijaykrishnan, Raj
    Gopinathannair, Rakesh
    ARTIFICIAL ORGANS, 2021, 45 (08) : 845 - 851
  • [7] Implantable cardioverter-defibrillator shocks in patients with a left ventricular assist device
    Ambardekar, Amrut V.
    Allen, Larry A.
    Lindenfeld, JoAnn
    Lowery, Christopher M.
    Cannon, Anne P.
    Cleveland, Joseph C., Jr.
    Brieke, Andreas
    Sauer, William H.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (07): : 771 - 776
  • [8] Eligibility for subcutaneous implantable cardioverter-defibrillator in patients with left ventricular assist device
    Christos Zormpas
    Jörg Eiringhaus
    Henrike A. K. Hillmann
    Stephan Hohmann
    Johanna Müller-Leisse
    Jan D. Schmitto
    Christian Veltmann
    David Duncker
    Journal of Interventional Cardiac Electrophysiology, 2021, 60 : 303 - 311
  • [9] Eligibility for subcutaneous implantable cardioverter-defibrillator in patients with left ventricular assist device
    Zormpas, Christos
    Eiringhaus, Joerg
    Hillmann, Henrike A. K.
    Hohmann, Stephan
    Mueller-Leisse, Johanna
    Schmitto, Jan D.
    Veltmann, Christian
    Duncker, David
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2021, 60 (02) : 303 - 311
  • [10] Ventricular Arrhythmias in Patients With a Continuous-Flow Left Ventricular Assist Device
    Yap, Sing-Chien
    Ramjankhan, Faiz
    de Jonge, Rahat Muslem Nicolaas
    Kirkels, Hans J.
    Akin, Sakir
    Manintveld, Olivier C.
    Birim, Ozcan
    Szili-Torok, Tamas
    Caliskan, Kadir
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (03) : 323 - 325