A Model of Regularization Parameter Determination in Low-Dose X-Ray CT Reconstruction Based on Dictionary Learning

被引:10
|
作者
Zhang, Cheng [1 ,2 ,3 ]
Zhang, Tao [2 ]
Zheng, Jian [1 ]
Li, Ming [1 ,2 ,3 ]
Lu, Yanfei [1 ,2 ,3 ]
You, Jiali [1 ,2 ,3 ]
Guan, Yihui [4 ]
机构
[1] Chinese Acad Sci, Suzhou Inst Biomed Engn & Technol, Med Imaging Lab, Suzhou 215163, Peoples R China
[2] Chinese Acad Sci, Changchun Inst Opt Fine Mech & Phys, Changchun 130033, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[4] Fudan Univ, Huashan Hosp, PET Ctr, Shanghai 200235, Peoples R China
基金
中国国家自然科学基金;
关键词
ORTHOGONAL MATCHING PURSUIT; IMAGE-RECONSTRUCTION; COMPUTED-TOMOGRAPHY; SIGNAL RECOVERY; SPARSE; PROJECTIONS; ALGORITHM; CHOICE;
D O I
10.1155/2015/831790
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
In recent years, X-ray computed tomography (CT) is becoming widely used to reveal patient's anatomical information. However, the side effect of radiation, relating to genetic or cancerous diseases, has caused great public concern. The problem is how to minimize radiation dose significantly while maintaining image quality. As a practical application of compressed sensing theory, one category of methods takes total variation (TV) minimization as the sparse constraint, which makes it possible and effective to get a reconstruction image of high quality in the undersampling situation. On the other hand, a preliminary attempt of low-dose CT reconstruction based on dictionary learning seems to be another effective choice. But some critical parameters, such as the regularization parameter, cannot be determined by detecting datasets. In this paper, we propose a reweighted objective function that contributes to a numerical calculation model of the regularization parameter. A number of experiments demonstrate that this strategy performs well with better reconstruction images and saving of a large amount of time.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Low-Dose X-ray CT Reconstruction via Dictionary Learning
    Xu, Qiong
    Yu, Hengyong
    Mou, Xuanqin
    Zhang, Lei
    Hsieh, Jiang
    Wang, Ge
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (09) : 1682 - 1697
  • [2] Dictionary Learning Based Low-dose X-ray CT Reconstruction Using a Balancing Principle
    Mou, Xuanqin
    Wu, Junfeng
    Bai, Ti
    Xu, Qiong
    Yu, Hengyong
    Wang, Ge
    [J]. DEVELOPMENTS IN X-RAY TOMOGRAPHY IX, 2014, 9212
  • [3] Region-Specific Dictionary Learning for Low-Dose X-Ray CT Reconstruction
    Xu, Q.
    Han, H.
    Xing, L.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3389 - 3389
  • [4] Smoothed L0-Constraint Dictionary Learning for Low-Dose X-Ray CT Reconstruction
    Komolafe, Temitope E.
    Wang, Kang
    Du, Qiang
    Hu, Tao
    Yuan, Gang
    Zheng, Jian
    Zhang, Cheng
    Li, Ming
    Yang, Xiaodong
    [J]. IEEE ACCESS, 2020, 8 : 116961 - 116973
  • [5] Low-Dose X-ray CT Reconstruction Algorithm Using Shearlet Sparse Regularization
    Xiao, Dayu
    Zhang, Xiaotong
    Li, Jianhua
    Bao, Nan
    Kang, Yan
    [J]. JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2020, 10 (03) : 620 - 627
  • [6] Regularization strategies in statistical image reconstruction of low-dose x-ray CT: A review
    Zhang, Hao
    Wang, Jing
    Zeng, Dong
    Tao, Xi
    Ma, Jianhua
    [J]. MEDICAL PHYSICS, 2018, 45 (10) : E886 - E907
  • [7] Adaptive nonlocal means-based regularization for statistical image reconstruction of low-dose X-ray CT
    Zhang, Hao
    Ma, Jianhua
    Wang, Jing
    Liu, Yan
    Han, Hao
    Li, Lihong
    Moore, William
    Liang, Zhengrong
    [J]. MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [8] LOW-DOSE X-RAY CT RECONSTRUCTION BASED ON JOINT SINOGRAM SMOOTHING AND LEARNED DICTIONARY-BASED REPRESENTATION
    Stojanovic, Ivana
    Pien, Homer
    Do, Synho
    Karl, W. Clem
    [J]. 2012 9TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2012, : 1012 - 1015
  • [9] Adaptive Combined Denoising Based Low-dose X-ray CT Reconstruction
    Wang, Hangzhong
    Ma, Huizhu
    [J]. PROCEEDINGS OF 2012 IEEE 11TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING (ICSP) VOLS 1-3, 2012, : 1650 - 1653
  • [10] Low-dose CT Reconstruction Based on Multiscale Dictionary
    Bai, Ti
    Mou, Xuanqin
    Xu, Qiong
    Zhang, Yanbo
    [J]. MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668