A novel approach to transforming a non-targeted metabolic profiling method to a pseudo-targeted method using the retention time locking gas chromatography/mass spectrometry-selected ions monitoring

被引:82
|
作者
Li, Yong [1 ]
Ruan, Qiang [2 ]
Li, Yanli [1 ]
Ye, Guozhu [1 ]
Lu, Xin [1 ]
Lin, Xiaohui [2 ]
Xu, Guowang [1 ]
机构
[1] Chinese Acad Sci, Dalian Inst Chem Phys, CAS Key Lab Separat Sci Analyt Chem, Dalian 116023, Peoples R China
[2] Dalian Univ Technol, Sch Comp Sci & Technol, Dept Comp Sci &Engn, Dalian 116024, Peoples R China
基金
中国国家自然科学基金;
关键词
Retention time locking; Gas chromatography/mass spectrometry; Metabolic profiling; Full scan; Selected ion monitoring; FLIGHT MASS-SPECTROMETRY; PESTICIDE-RESIDUE ANALYSIS; BIOMARKER DISCOVERY; GC-MS; SCAN; FOOD; QUANTIFICATION; IDENTIFICATION; ADVANTAGES; GENOMICS;
D O I
10.1016/j.chroma.2012.01.076
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Non-targeted metabolic profiling is the most widely used method for metabolomics. In this paper, a novel approach was established to transform a non-targeted metabolic profiling method to a pseudo-targeted method using the retention time locking gas chromatography/mass spectrometry-selected ion monitoring (RTL-GC/MS-SIM). To achieve this transformation, an algorithm based on the automated mass spectral deconvolution and identification system (AMDIS), GC/MS raw data and a bi-Gaussian chromatographic peak model was developed. The established GC/MS-SIM method was compared with GC/MS-full scan (the total ion current and extracted ion current, TIC and EIC) methods, it was found that for a typical tobacco leaf extract, 93% components had their relative standard deviations (RSDs) of relative peak areas less than 20% by the SIM method, while 88% by the EIC method and 81% by the TIC method. 47.3% components had their linear correlation coefficient higher than 0.99, compared with 5.0% by the EIC and 6.2% by TIC methods. Multivariate analysis showed the pooled quality control samples clustered more tightly using the developed method than using GC/MS-full scan methods, indicating a better data quality. With the analysis of the variance of the tobacco samples from three different planting regions, 167 differential components (p < 0.05) were screened out using the RTL-GC/MS-SIM method, but 151 and 131 by the EIC and TIC methods, respectively. The results show that the developed method not only has a higher sensitivity, better linearity and data quality, but also does not need complicated peak alignment among different samples. It is especially suitable for the screening of differential components in the metabolic profiling investigation. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:228 / 236
页数:9
相关论文
共 20 条
  • [1] Establishment of Retention Index Library on Gas Chromatography-Mass Spectrometry for Non-targeted Metabolite Profiling Approach
    Choi, Hoon
    Moon, Joon-Kwan
    Seo, Jong-Su
    Kim, Jeong-Han
    JOURNAL OF THE KOREAN SOCIETY FOR APPLIED BIOLOGICAL CHEMISTRY, 2013, 56 (01): : 87 - 90
  • [2] Development of a metabolic pathway-based pseudo-targeted metabolomics method using liquid chromatography coupled with mass spectrometry
    Xu, Jing
    Li, Jiangshuo
    Zhang, Ruiping
    He, Jiuming
    Chen, Yanhua
    Bi, Nan
    Song, Yongmei
    Wang, Luhua
    Zhan, Qimin
    Abliz, Zeper
    TALANTA, 2019, 192 : 160 - 168
  • [3] A non-targeted gas chromatography/electron capture negative ionization mass spectrometry selected ion monitoring screening method for polyhalogenated compounds in environmental samples
    Hauler, Carolin
    Vetter, Walter
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2015, 29 (07) : 619 - 628
  • [4] Discrimination of Adzuki Bean (Vigna angularis) Geographical Origin by Targeted and Non-Targeted Metabolite Profiling with Gas Chromatography Time-of-Flight Mass Spectrometry
    Kim, Tae Jin
    Park, Jeong Gon
    Ahn, Soon Kil
    Kim, Kil Won
    Choi, Jaehyuk
    Kim, Hyun Young
    Ha, Sun-Hwa
    Seo, Woo Duck
    Kim, Jae Kwang
    METABOLITES, 2020, 10 (03)
  • [5] A novel non-targeted screening method for urinary exposure biomarker discovery of phthalates using liquid chromatography-mass spectrometry
    Yao, Chunhe
    Wang, Jianhua
    Chan, Peter
    Feng, Yong-Lai
    ANALYTICAL METHODS, 2018, 10 (09) : 959 - 967
  • [6] Novel approach for the non-targeted profiling of oligomeric nutraceuticals in fruits using reporter-ion triggered tandem mass spectrometry
    Tharayil, Nishanth
    Leonard, Elizabeth
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 258
  • [7] Metabolic profiling of Goji berry extracts for discrimination of geographical origin by non-targeted liquid chromatography coupled to quadrupole time-of-flight mass spectrometry
    Bondia-Pons, Isabel
    Savolainen, Otto
    Torronen, Riitta
    Martinez, J. Alfredo
    Poutanen, Kaisa
    Hanhineva, Kati
    FOOD RESEARCH INTERNATIONAL, 2014, 63 : 132 - 138
  • [8] A targeted/non-targeted screening method for perfluoroalkyl carboxylic acids and sulfonates in whole fish using quadrupole time-of-flight mass spectrometry and MSe
    Bernard S. Crimmins
    Xiaoyan Xia
    Philip K. Hopke
    Thomas M. Holsen
    Analytical and Bioanalytical Chemistry, 2014, 406 : 1471 - 1480
  • [9] A targeted/non-targeted screening method for perfluoroalkyl carboxylic acids and sulfonates in whole fish using quadrupole time-of-flight mass spectrometry and MSe
    Crimmins, Bernard S.
    Xia, Xiaoyan
    Hopke, Philip K.
    Holsen, Thomas M.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (05) : 1471 - 1480
  • [10] A split-range acquisition method for the non-targeted metabolomic profiling of human plasma with hydrophilic interaction chromatography - high-resolution mass spectrometry
    Fall, Fanta
    Lenuzza, Natacha
    Lamy, Elodie
    Brollo, Marion
    Naline, Emmanuel
    Devillier, Philippe
    Thevenot, Etienne
    Grassin-Delyle, Stanislas
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1128