Detection and monitoring of biofilm formation in water treatment systems by quartz crystal microbalance sensors

被引:16
|
作者
Sprung, C. [1 ]
Waehlisch, D. [1 ]
Huettl, R. [1 ]
Seidel, J. [1 ]
Meyer, A. [2 ]
Wolf, G. [1 ]
机构
[1] Tech Univ Bergakad Freiberg, Inst Phys Chem, D-09596 Freiberg, Germany
[2] UMEX GmbH Dresden, D-01109 Dresden, Germany
关键词
biofilm detection; coated quartz; quartz crystal microbalance technology; water quality monitoring; LONG-TERM;
D O I
10.2166/wst.2009.001
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Investigations are presented for the development and testing of a sensor for the early stage detection and monitoring of biofilm formation. The sensor is based on the well known quartz crystal microbalance technology (QCM). The QCM detectors are integrated into the water flow system and provide continuous in-situ signals. The main objectives of the research are the evaluation of optimal operation conditions and the modification of the quartz resonator surface promoting a preferred cell attachment onto the quartz sensor surface. The miniaturization degree of the mass sensitive detector modules permits the integration into industrial plants, e. g., in order to control and ensure perfect hygienic conditions. First results of the lab study using Pseudomonas putida cultures are presented and discussed.
引用
收藏
页码:543 / 548
页数:6
相关论文
共 50 条
  • [1] Explosives Detection in Sea Water with Phthalocyanine Quartz Crystal Microbalance Sensors
    Erbahar, Dilek D.
    Gurol, Ilke
    Ahsen, Vefa
    Ozturk, Zafer Ziya
    Musluoglu, Emel
    Harbeck, Mika
    SENSOR LETTERS, 2011, 9 (02) : 745 - 748
  • [2] Real-time monitoring of Streptococcus mutans biofilm formation using a quartz crystal microbalance
    Tam, K.
    Kinsinger, N.
    Ayala, P.
    Qi, F.
    Shi, W.
    Myung, N. V.
    CARIES RESEARCH, 2007, 41 (06) : 474 - 483
  • [3] Respiratory Monitoring by Porphyrin Modified Quartz Crystal Microbalance Sensors
    Selyanchyn, Roman
    Korposh, Serhiy
    Wakamatsu, Shunichi
    Lee, Seung-Woo
    SENSORS, 2011, 11 (01) : 1177 - 1191
  • [4] A nanocell for quartz crystal microbalance and quartz crystal microbalance with dissipation-monitoring sensing
    Ohlsson, Gabriel
    Langhammer, Christoph
    Zoric, Igor
    Kasemo, Bengt
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (08):
  • [5] Detecting odorous materials in water using quartz crystal microbalance sensors
    Ogawa, S
    Sugimoto, I
    WATER SCIENCE AND TECHNOLOGY, 2002, 45 (4-5) : 201 - 206
  • [6] Pesticide monitoring with a quartz crystal microbalance
    Perkel, Jeffrey M.
    ANALYTICAL CHEMISTRY, 2009, 81 (03) : 859 - 859
  • [7] Detection of biofilm activities using chip calorimetry and quartz crystal microbalance technology
    Wolf, A.
    Lerchner, J.
    Huettl, R.
    Seidel, J.
    Mertens, F.
    Buchholz, F.
    Maskow, T.
    Neu, T.
    INTERNATIONAL JOURNAL OF MEDICAL MICROBIOLOGY, 2008, 298 : 33 - 33
  • [8] Reusable and recyclable quartz crystal microbalance sensors
    Sekar, Sribharani
    Giermanska, Joanna
    Chapel, Jean-Paul
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 212 : 196 - 199
  • [9] Measurement system for quartz crystal microbalance sensors
    Araki, Hideo
    Omatu, Sigeru
    ARTIFICIAL LIFE AND ROBOTICS, 2012, 17 (02) : 270 - 274
  • [10] MEMS biosensor for monitoring water toxicity based on quartz crystal microbalance
    Lee, Kun-Lin
    Ng, Simon
    Li, Fang
    Nordin, Anis Nurashikin
    Voiculescu, Ioana
    BIOINTERPHASES, 2020, 15 (02)