Soft X-ray emission from molybdenum plasmas generated by dual laser pulses

被引:23
|
作者
Lokasani, Ragava [1 ,2 ]
Arai, Goki [3 ]
Kondo, Yoshiki [3 ]
Hara, Hiroyuki [3 ]
Thanh-Hung Dinh [3 ,4 ]
Ejima, Takeo [5 ]
Hatano, Tadashi [5 ]
Jiang, Weihua [6 ]
Makimura, Tetsuya [7 ]
Li, Bowen [8 ]
Dunne, Padraig [2 ]
O'Sullivan, Gerry [2 ]
Higashiguchi, Takeshi [3 ,9 ]
Limpouch, Jiri [1 ]
机构
[1] Czech Tech Univ, Fac Nucl Sci & Phys Engn, Brehova 7, CZ-11519 Prague 1, Czech Republic
[2] Univ Coll Dublin, Sch Phys, Dublin 4, Ireland
[3] Utsunomiya Univ, Fac Engn, Dept Elect & Elect Engn, Yoto 7-1-2, Utsunomiya, Tochigi 3218585, Japan
[4] Natl Inst Quantum & Radiol Sci & Technol QST, Kansai Photon Sci Inst, 8-1-7 Umemidai, Kizugawa, Kyoto 6190215, Japan
[5] Tohoku Univ, Inst Multidisciplinary Res Adv Mat, Aoba Ku, 2-1-1 Katahira, Sendai, Miyagi 9808577, Japan
[6] Nagaoka Univ Technol, Dept Elect Engn, Nagaoka, Niigata 9402188, Japan
[7] Univ Tsukuba, Inst Appl Phys, Tsukuba, Ibaraki 3058573, Japan
[8] Lanzhou Univ, Sch Nucl Sci & Technol, Lanzhou 730000, Peoples R China
[9] Utsunomiya Univ, CORE, Yoto 7-1-2, Utsunomiya, Tochigi 3218585, Japan
基金
爱尔兰科学基金会;
关键词
SUBPICOSECOND LASER; PREPULSE; MICROSCOPY; DEPENDENCE;
D O I
10.1063/1.4967310
中图分类号
O59 [应用物理学];
学科分类号
摘要
We demonstrate efficient enhancement of soft X-ray (SXR) emission from molybdenum plasmas produced using dual pulse irradiation, in which 10-ns and 150-ps pre-pulses were followed by a 150-ps main pulse. The number of photons was observed to be 5.3 x 10(16) photons/sr, which corresponded to a conversion efficiency of 1.5%/sr in lambda = 2.34-4.38 nm region at a pulse separation time of 1 ns with the 150-ps pre-pulse. The conversion efficiency became 1.3 times as large as that produced by a single pulse. The results indicate the advantage of dual pulse irradiation using sub-ns pre- and main pulses to produce the bright plasmas required for applications such as laboratory based SXR microscopy. Published by AIP Publishing.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] X-RAY EMISSION FROM LASER GENERATED PLASMAS
    MALLOZZI, PJ
    EPSTEIN, HM
    JUNG, RG
    FAIRAND, BP
    GALLAGHE.WJ
    APPLEBAU.DC
    [J]. BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1971, 16 (01): : 127 - &
  • [2] X-ray emission from plasmas generated by 450 femtosecond excimer laser pulses
    Tatarakis, M
    Beg, FN
    Lee, P
    Dangor, AE
    Moustaizis, SD
    [J]. PHYSICA SCRIPTA, 1997, 55 (06): : 651 - 653
  • [3] X-ray emission from solid plasmas generated by femtosecond high-intensity laser pulses
    Banerjee, S
    Issac, RC
    Rajeev, PP
    Tribedi, LC
    Kumar, GR
    [J]. HIGH-POWER LASERS IN ENERGY ENGINEERING, 2000, 3886 : 596 - 602
  • [4] Soft x-ray emission from plasmas produced by ultraintense KrF-laser pulses in colloidal Al
    Wulker, C
    Theobald, W
    Gnass, DR
    Schafer, FP
    Bakos, JS
    Sauerbrey, R
    Gordon, SP
    Falcone, RW
    [J]. APPLIED PHYSICS LETTERS, 1996, 68 (10) : 1338 - 1340
  • [5] X-RAY-EMISSION FROM LASER GENERATED PLASMAS
    MALLOZZI, PJ
    [J]. IEEE JOURNAL OF QUANTUM ELECTRONICS, 1972, QE 8 (06) : 539 - &
  • [6] Soft x-ray emission from postpulse expanding laser-produced plasmas
    Weaver, JL
    Feldman, U
    Mostovych, AN
    Seely, JF
    Colombant, D
    Holland, G
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (12): : 5076 - 5083
  • [7] Photoionized Xeon Cluster Plasmas Generated by a Soft X-Ray Laser Pulse
    Namba, S.
    Takiyama, K.
    [J]. 5TH INTERNATIONAL CONFERENCE ON INERTIAL FUSION SCIENCES AND APPLICATIONS (IFSA2007), 2008, 112
  • [8] Measurements of laser generated soft X-ray emission from irradiated gold foils
    Davis, J. S.
    Frank, Y.
    Raicher, E.
    Fraenkel, M.
    Keiter, P. A.
    Klein, S. R.
    Drake, R. P.
    Shvarts, D.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (11):
  • [9] VUV and soft x-ray emission from pre-plasmas irradiated with picosecond and femtosecond pulses
    Murphy, A
    Hirsch, JS
    Kilbane, D
    Kennedy, ET
    Khater, MA
    Mosnier, JP
    Neogi, A
    O'Sullivan, G
    Lewis, CLS
    Topping, S
    Clarke, R
    Divall, E
    Foster, P
    Hooker, C
    Langley, A
    Neely, D
    Dunne, P
    Costello, JT
    [J]. OPTO-IRELAND 2002: OPTICS AND PHOTONICS TECHNOLOGIES AND APPLICATIONS, PTS 1 AND 2, 2003, 4876 : 1196 - 1203
  • [10] X-ray emission from laser-generated plasmas recorded by a transmission crystal spectrometer
    Seely, JF
    Doron, R
    Bar-Shalom, A
    Hudson, LT
    Stoeckl, C
    [J]. LASER-GENERATED AND OTHER LABORATORY X-RAY AND EUV SOURCES, OPTICS, AND APPLICATIONS, 2003, 5196 : 177 - 184