Management and results in periprosthetic tibial fracture after total knee arthroplasty: Two-center 15-case retrospective series at 2 years' follow-up

被引:8
|
作者
Bauer, Camille [1 ]
Zaharia, Bogdan [1 ]
Galliot, Florent [1 ]
Parot, Jauffrey [1 ]
Houfani, Faycal [1 ]
Mayer, Julien [2 ]
Mainard, Didier [1 ]
机构
[1] CHRU Nancy, Serv Chirurg Orthoped & Traumatol, Hop Cent, COTA, 29 Ave Marechal de Lattre de Tassigny, F-54000 Nancy, France
[2] CHR Metz Thionville, Serv Chirurg Orthoped & Traumatol, Hop Mercy, 1 Allee Chateau, F-57245 Ars Laquenexy, France
关键词
Total knee arthroplasty; Tibial fracture; Knee revision; Periprosthetic fracture; REPLACEMENT; IMPLANT; FEMUR;
D O I
10.1016/j.otsr.2020.01.008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Periprosthetic tibial fracture after total knee arthroplasty (TKA) is rare, but jeopardizes implant survival. The main objective of the present study was to assess treatment efficacy, on the hypothesis that surgery provides good long-term results. Material and methods: A two-center retrospective study included 15 patients (6 male, 9 female: mean age, 71.8 +/- 10.2 years), managed between 1997 and 2017 for isolated tibial fracture after TKA. Patients were assessed clinically (IKS, inverted Oxford, Parker and SF-12 scores) and radiologically. Complications and revision surgeries were collated. Fractures were classified on the SoFCOT classification: 9 stable implants (4 type B1, 5 type C1), 4 periprosthetic osteolyses (1 type A3, 2 type B3, 1 type C3), and 2 loosenings (type A2). Treatments comprised: non-operative treatment (1 bed-ridden patient), 11 osteosyntheses for fracture on stable implant (2 standard plates, 7 locking plates, 2 intramedullary nailings), and 3 implant replacements by cemented long stem models for loosening. Results: Mean follow-up was 28 months (range, 12-120 months). Consolidation was achieved in 13 cases, at a mean 15 weeks. Complications comprised: 4 infections, 2 cases of secondary displacement, and 2 of non-union. Surgical revision was required in 8 cases, including 2 secondary implant revision procedures. Functional results were good in 10 cases. At last follow-up, mean Parker score was 7 (range, 4-8.5), Oxford score 32 (range, 16-39), and IKS score 150 (range, 85-167) with knee and function scores respectively 78 (range, 55-86) and 75 (range, 30-85). Conclusion: Radiologic and clinical results were encouraging, but with impaired quality of life and a high rate of complications. (C) 2020 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:449 / 458
页数:10
相关论文
共 50 条
  • [1] Periprosthetic early insufficiency fracture after total knee arthroplasty: a retrospective case series
    Jabalameli, Mahmoud
    Abedi, Majid
    Yahyazadeh, Hooman
    Sobhan, Mohammad Reza
    CURRENT ORTHOPAEDIC PRACTICE, 2021, 32 (03): : 237 - 241
  • [2] Case report:A 10 years follow-up of periprosthetic femoral fracture after total hip arthroplasty in osteopetrosis
    Zhan-Feng Zhang
    Dan Wang
    Li-Dong Wu
    Xue-Song Dai
    中华创伤杂志英文版, 2017, 20 (03)
  • [3] Case report: A 10 years follow-up of periprosthetic femoral fracture after total hip arthroplasty in osteopetrosis
    Zhang ZhanFeng
    Wang Dan
    Wu LiDong
    Dai XueSong
    中华创伤杂志英文版, 2017, 20 (03)
  • [4] Bilateral periprosthetic tibial stress fracture after total knee arthroplasty: A case report
    Ozdemir, Guzelali
    Azboy, Ibrahim
    Yilmaz, Baris
    INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS, 2016, 24 : 175 - 178
  • [5] TOTAL KNEE ARTHROPLASTY WITH THE KINEMATIC PROSTHESIS - RESULTS AFTER 5 TO 9 YEARS - A FOLLOW-UP NOTE
    WRIGHT, J
    EWALD, FC
    WALKER, PS
    THOMAS, WH
    POSS, R
    SLEDGE, CB
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (07): : 1003 - 1009
  • [6] Periprosthetic tibial bone mineral density changes after total knee arthroplasty A 7-year follow-up of 86 patients
    Jaroma, Antti
    Soininvaara, Tarja
    Kroger, Heikki
    ACTA ORTHOPAEDICA, 2016, 87 (03) : 268 - 273
  • [7] Hinged total knee arthroplasty for fracture cases: Retrospective study of 52 patients with a mean follow-up of 5 years
    Kouyoumdjian, Pascal
    Coulomb, Remy
    d'Ambrosio, Adrien
    Ravoyard, Salome
    Cavaignac, Etienne
    Pasquier, Gilles
    Ehlinger, Matthieu
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2020, 106 (03) : 389 - 395
  • [8] Atraumatic Lateral Tibial Plateau Periprosthetic Insufficiency Fracture after Primary Total Knee Arthroplasty: A Case Report
    Abdelaal, Ahmed M.
    Khalifa, Ahmed A.
    REPORTS, 2024, 7 (02)
  • [9] The early results of high-flex total knee arthroplasty - A minimum of 2 years of follow-up
    Huang, HT
    Su, AY
    Wang, GJ
    JOURNAL OF ARTHROPLASTY, 2005, 20 (05): : 674 - 679
  • [10] The fate of patients not returning for follow-up five years after total knee arthroplasty
    King, PJ
    Malin, AS
    Scott, RD
    Thornhill, TS
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (05): : 897 - 901