Characterization of flat miniature loop heat pipe using water and methanol at different inclinations

被引:6
|
作者
Veeramachaneni, Sireesha [1 ,2 ]
Pisipaty, Srinivas Kishore [3 ]
Vedula, Dharma Rao [2 ]
Solomon, A. Brusly [4 ]
机构
[1] Andhra Univ, Coll Engn A, Visakhapatnam, Andhra Pradesh, India
[2] Gayatri Vidya Parishad Coll Engn Autonomous, Dept Mech Engn, Visakhapatnam, Andhra Pradesh, India
[3] Andhra Univ, Coll Engn A, Dept Mech Engn, Visakhapatnam, Andhra Pradesh, India
[4] Karunya Inst Technol & Sci, Dept Mech Engn, Ctr Res Mat Sci & Thermal Management, Coimbatore, Tamil Nadu, India
关键词
Loop heat pipe; heat transfer; capillary limit; orientations of heat pipe; dryout; TRANSFER PERFORMANCE; EVAPORATOR; WICK; TRANSPORT; TESTS; FLOW;
D O I
10.1080/08916152.2020.1800136
中图分类号
O414.1 [热力学];
学科分类号
摘要
Experiments have been conducted on a flat rectangular loop heat pipe with water and methanol at heat loads from 40 to 320 W at three orientations of the heat pipe (0 degrees, 45 degrees, 90 degrees) and two filling ratios (33% and 50%). Performance parameters such as thermal resistance, effective thermal conductivity and capillary limit are calculated from the experimental data. The results exhibited that the thermal performance of water is better than methanol with least thermal resistance 0.13 K/W, maximum capillary limit 2626.72 W and an effective thermal conductivity 84490.48 W/mK at a heat load 320 W in horizontal position for 33% filling ratio.
引用
收藏
页码:639 / 661
页数:23
相关论文
共 50 条
  • [1] An experimental investigation of miniature loop heat pipe with flat evaporator
    Gai, Dongxing
    Liu, Wei
    Liu, Zhichun
    Yang, Jinguo
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 3960 - 3963
  • [2] Operational characteristics of miniature loop heat pipe with flat evaporator
    Dongxing Gai
    Zhichun Liu
    Wei Liu
    Jinguo Yang
    Heat and Mass Transfer, 2009, 46 : 267 - 275
  • [3] Operational characteristics of miniature loop heat pipe with flat evaporator
    Gai, Dongxing
    Liu, Zhichun
    Liu, Wei
    Yang, Jinguo
    HEAT AND MASS TRANSFER, 2009, 46 (02) : 267 - 275
  • [4] Operational characteristics of a miniature loop heat pipe with flat evaporator
    Singh, Randeep
    Akbarzadeh, Aliakbar
    Mochizuki, Masataka
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2008, 47 (11) : 1504 - 1515
  • [5] Miniature loop heat pipe with flat evaporator for cooling computer CPU
    Singh, Randeep
    Akbarzadeh, Aliakbar
    Dixon, Chris
    Mochizuki, Mastaka
    Riehl, Roger R.
    IEEE TRANSACTIONS ON COMPONENTS AND PACKAGING TECHNOLOGIES, 2007, 30 (01): : 42 - 49
  • [6] Characteristics of temperature oscillation in miniature loop heat pipe with flat evaporator
    Gai, Dongxing
    Liu, Zhichun
    Liu, Wei
    Yang, Jinguo
    Huagong Xuebao/CIESC Journal, 2009, 60 (06): : 1390 - 1397
  • [7] Experimental Investigation of Heat Transfer Performance of A Miniature Loop Heat Pipe with Flat Evaporator
    Zhang, Xianfeng
    Wang, Shuangfeng
    FRONTIERS OF GREEN BUILDING, MATERIALS AND CIVIL ENGINEERING, PTS 1-8, 2011, 71-78 : 3806 - 3809
  • [8] Experimental study on operating parameters of miniature loop heat pipe with flat evaporator
    Wang, Shuangfeng
    Huo, Jiepeng
    Zhang, Xianfeng
    Lin, Zirong
    APPLIED THERMAL ENGINEERING, 2012, 40 : 318 - 325
  • [9] Experimental investigation on temperature oscillation in a miniature loop heat pipe with flat evaporator
    Zhang, Xianfeng
    Huo, Jiepeng
    Wang, Shuangfeng
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2012, 37 : 29 - 36
  • [10] Fabrication and testing of a miniature flat evaporator loop heat pipe with polydimethylsiloxane and molding
    Nguyen Phan
    Nagano, Hosei
    APPLIED THERMAL ENGINEERING, 2020, 175