Computer-Aided Diagnostic System for Detection of Hashimoto Thyroiditis on Ultrasound Images From a Polish Population

被引:49
|
作者
Acharya, U. Rajendra [1 ,2 ]
Sree, S. Vinitha [3 ]
Krishnan, M. Muthu Rama [1 ]
Molinari, Filippo [4 ]
Zieleznik, Witold
Bardales, Ricardo H. [5 ]
Witkowska, Agnieszka [6 ]
Suri, Jasjit S. [7 ,8 ,9 ]
机构
[1] Ngee Ann Polytech, Dept Elect & Comp Engn, Singapore, Singapore
[2] Univ Malaya, Fac Engn, Dept Biomed Engn, Kuala Lumpur, Malaysia
[3] Global Biomed Technol Inc, Roseville, CA 95661 USA
[4] Politecn Torino, Dept Elect & Telecommun, Biolab, Turin, Italy
[5] Outpatient Pathol Associates, Sacramento, CA USA
[6] Med Univ Silesia, Dept Internal Med Diabetol & Nephrol, Zabrze, Poland
[7] Idaho State Univ Affiliate, Dept Elect Engn, Pocatello, ID USA
[8] Global Biomed Technol Inc, Point Of Care Devices Div, Roseville, CA 95661 USA
[9] AtheroPoint LLC, Roseville, CA USA
关键词
computer-aided-diagnosis; general ultrasound; Hashimoto disease; Hashimoto thyroiditis; sonography; stationary wavelet transform; TISSUE CHARACTERIZATION; LESION CLASSIFICATION; ULTRASONOGRAPHY; COMBINATION; TEXTURES; DISEASE; BENIGN;
D O I
10.7863/ultra.33.2.245
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives-Computer-aided diagnostic (CAD) techniques aid physicians in better diagnosis of diseases by extracting objective and accurate diagnostic information from medical data. Hashimoto thyroiditis is the most common type of inflammation of the thyroid gland. The inflammation changes the structure of the thyroid tissue, and these changes are reflected as echogenic changes on ultrasound images. In this work, we propose a novel CAD system (a class of systems called ThyroScan) that extracts textural features from a thyroid sonogram and uses them to aid in the detection of Hashimoto thyroiditis. Methods-In this paradigm, we extracted grayscale features based on stationary wavelet transform from 232 normal and 294 Hashimoto thyroiditis affected thyroid ultrasound images obtained from a Polish population. Significant features were selected using a Student t test. The resulting feature vectors were used to build and evaluate the following 4 classifiers using a 10-fold stratified cross-validation technique: support vector machine, decision tree, fuzzy classifier, and K-nearest neighbor. Results-Using 7 significant features that characterized the textural changes in the images, the fuzzy classifier had the highest classification accuracy of 84.6%, sensitivity of 82.8%, specificity of 87.0%, and a positive predictive value of 88.9%. Conclusions-The proposed ThyroScan CAD system uses novel features to noninvasively detect the presence of Hashimoto thyroiditis on ultrasound images. Compared to manual interpretations of ultrasound images, the CAD system offers a more objective interpretation of the nature of the thyroid. The preliminary results presented in this work indicate the possibility of using such a CAD system in a clinical setting after evaluating it with larger databases in multicenter clinical trials.
引用
收藏
页码:245 / 253
页数:9
相关论文
共 50 条
  • [1] Investigating the diagnostic efficiency of a computer-aided diagnosis system for thyroid nodules in the context of Hashimoto's thyroiditis
    Gong, Liu
    Zhou, Ping
    Li, Jia-Le
    Liu, Wen-Gang
    [J]. FRONTIERS IN ONCOLOGY, 2023, 12
  • [2] Computer-Aided Diagnosis System for Pancreatic Tumor Detection in Ultrasound Images
    Wu, C.
    Lin, M. H.
    Su, J. L.
    [J]. 5TH KUALA LUMPUR INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING 2011 (BIOMED 2011), 2011, 35 : 627 - +
  • [3] Computer-aided diagnostic detection system of venous beading in retinal images
    Yang, CW
    Ma, DJ
    Chao, SC
    Wang, CM
    Wen, CH
    Lo, CS
    Chung, PC
    Chang, CI
    [J]. OPTICAL ENGINEERING, 2000, 39 (05) : 1293 - 1303
  • [4] The Value of Thyroid Ultrasound Computer-Aided Diagnosis System in the Evaluation of Thyroid Nodules With Concurrent Hashimoto's Thyroiditis
    Hu, Minxia
    Zong, Suting
    Xu, Ning
    Li, Jinzhen
    Xia, Chunxia
    Yu, Fengxia
    Zhu, Qiang
    Zhao, Hanxue
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2022, 41 (05) : 1117 - 1124
  • [5] Computer-aided thyroid nodule detection in ultrasound images
    Maroulis, DE
    Savelonas, MA
    Karkanis, SA
    Iakovidis, DK
    Dimitropoulos, N
    [J]. 18TH IEEE SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS, PROCEEDINGS, 2005, : 271 - 276
  • [6] COMPUTER-AIDED DENSITOMETRY OF ULTRASOUND IMAGES
    BAHAWAR, H
    KINDLER, M
    BERWING, K
    SCHLEPPER, M
    [J]. ZEITSCHRIFT FUR KARDIOLOGIE, 1986, 75 : 120 - 120
  • [7] Diagnostic performance of ultrasound with computer-aided diagnostic system in detecting breast cancer
    Song, Pengjie
    Zhang, Li
    Bai, Longmei
    Wang, Qing
    Wang, Yanlei
    [J]. HELIYON, 2023, 9 (10)
  • [8] COMPUTER-AIDED DETECTION OF DIFFUSE LIVER-DISEASE IN ULTRASOUND IMAGES
    ABE, C
    KAHN, CE
    DOI, K
    KATSURAGAWA, S
    [J]. INVESTIGATIVE RADIOLOGY, 1992, 27 (01) : 71 - 77
  • [9] COMPUTER-AIDED EVALUATION OF ULTRASOUND IMAGES OF THE THYROID
    HELD, P
    NICKEL, O
    [J]. FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1984, 141 (02): : 185 - 191
  • [10] Computer-aided detection system of breast masses on ultrasound imag
    Ikedo, Yuji
    Fukuoka, Daisuke
    Hara, Takeshi
    Fujita, Hiroshi
    Takada, Etsuo
    Endo, Tokiko
    Morita, Takako
    [J]. MEDICAL IMAGING 2006: IMAGE PROCESSING, PTS 1-3, 2006, 6144