A Comparison of Cosmed Metabolic Systems for the Determination of Resting Metabolic Rate

被引:36
|
作者
Vandarakis, Dimitria [1 ]
Salacinski, Amanda J. [2 ]
Broeder, Craig E. [1 ]
机构
[1] Exercising Nutritionally LLC, Naperville, IL 60565 USA
[2] No Illinois Univ, De Kalb, IL 60115 USA
关键词
metabolism; metabolic cart systems; obesity; energy expenditure; ENERGY-EXPENDITURE;
D O I
10.1080/15438627.2012.757226
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
This study determined the reliability of measuring resting metabolic rate (RMR) with COSMED's FitMate metabolic system using a canopy dilution set-up compared with a previously validated COSMED QUARK CPET research-based system in 30 healthy adults (age: 28.4 +/- 7.0 yrs, weight: 79.9 +/- 20.2 kg, percent body fat: 22.5 +/- 8.6%). The FitMate was developed as an inexpensive metabolic system for RMR and fitness testing. Subjects were randomly assigned to start testing on either the FitMate or Quark CPET for four 10-minute measurements. Testretest intraclass correlations were 0.950.99, p 0.0001 for all parameters tested. Ve, RMR, VO2, and heart rate were not significantly different between the two systems. These results suggest that the FitMate is a reliable canopy dilution system for RMR measurements in healthy adults.
引用
收藏
页码:187 / 194
页数:8
相关论文
共 50 条
  • [1] Validation Of Cosmed's Fitmate In Measuring Resting Metabolic Rate
    Austin, Melanie D.
    Nieman, David C.
    Benezra, Laura
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 : S24 - S24
  • [2] The Reliability and Validity of the COSMED Fitmate Canopy System for Assessing Resting Metabolic Rate
    Vandarakis, Dimitria
    Salacinski, Amanda J.
    Broeder, Craig E.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 : 905 - 905
  • [3] A comparison of indirect calorimeters' measures of resting metabolic rate
    Kennedy, S.
    Fraser, A.
    Ryan, L.
    Clegg, M. E.
    PROCEEDINGS OF THE NUTRITION SOCIETY, 2013, 72 (OCE3) : E155 - E155
  • [4] Congruent Validity and Reliability of Two Metabolic Systems to Measure Resting Metabolic Rate
    Welch, W. A.
    Strath, S. J.
    Swartz, A. M.
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2015, 36 (05) : 414 - 418
  • [5] Resting Metabolic Rate And The Metabolic Equivalent (met)
    McMurray, Robert G.
    McCurdy, Thomas
    O'Brien, Meghan A.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2010, 42 (05): : 117 - 117
  • [6] Resting Metabolic Rate Of Specific Population Subgroups In Comparison To The Standard Metabolic Equivalent (MET)
    Melzer, Katarina
    Heydenreich, Juliane
    Schutz, Yves
    Renaud, Anne Renaud
    Kayser, Bengt
    Mader, Urs
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2016, 48 (05): : 549 - 549
  • [7] Resting Metabolic Rate of Individuals
    Plaza-Florido, Abel
    Alcantara, Juan M. A.
    METABOLITES, 2023, 13 (08)
  • [8] A low resting metabolic rate is associated with metabolic syndrome
    Buscemi, Silvio
    Verga, Salvatore
    Caimi, Gregorio
    Cerasola, Giovanni
    CLINICAL NUTRITION, 2007, 26 (06) : 806 - 809
  • [9] Comparison of Actual and Predicted Resting Metabolic Rate in Women with Lipedema
    Jeziorek, Malgorzata
    Szuba, Andrzej
    Kujawa, Krzysztof
    Regulska-Ilow, Bozena
    LYMPHATIC RESEARCH AND BIOLOGY, 2023, 21 (03) : 244 - 252
  • [10] Comparison between Medgem and Deltatrac resting metabolic rate measurements
    C Compher
    M Hise
    A Sternberg
    B P Kinosian
    European Journal of Clinical Nutrition, 2005, 59 : 1136 - 1141