A SIMPLE PHYSICAL PHANTOM FOR AN INTERCOMPARISON EXERCISE ON 241Am ACTIVITY DETERMINATION IN THE SKULL

被引:6
|
作者
Vrba, T. [1 ]
Malatova, I. [2 ]
Fojtik, P. [2 ]
Fulop, M. [3 ]
Ragan, P. [4 ]
机构
[1] Czech Tech Univ, Fac Nucl Sci & Phys Engn, CR-11519 Prague, Czech Republic
[2] Natl Radiat Protect Inst, Prague 14000, Czech Republic
[3] Slovak Med Univ, Bratislava 83303, Slovakia
[4] Publ Hlth Author Slovak Republ, Bratislava 82645, Slovakia
关键词
CALIBRATION;
D O I
10.1093/rpd/nct213
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A simple hemispherical phantom has been designed and prepared for the EURADOS intercomparison exercise on Am-241 activity determination in the skull (2011-13). The phantom consists of three parts that substitute bone and soft tissues. Am-241 is deposited on the surfaces of the bone-substituting part. The design and assumed composition of phantom parts are discussed. A preparation of the voxel representation of the phantom is described. The spectrum of a real measurement of the physical phantom agrees well with the simulation. The physical phantom, and its voxel representation, is provided to the participants of the intercomparison exercise.
引用
收藏
页码:224 / 229
页数:6
相关论文
共 50 条
  • [1] Intercomparison exercise for the determination of 241Am in the human skeleton
    Ruhm, W
    Konig, K
    Malatova, I
    Doerfel, H
    Foltanova, S
    Sahre, P
    Schutz, R
    Wahl, W
    RADIATION PROTECTION DOSIMETRY, 1998, 79 (1-4) : 517 - 521
  • [2] EURADOS 241Am skull measurement intercomparison
    Nogueira, P.
    Ruehm, W.
    Lopez, M. A.
    Vrba, T.
    Buchholz, V. V.
    Fojtik, P.
    Etherington, G.
    Broggio, D.
    Huikari, J.
    Marzocchi, .
    Lynch, T.
    Lebacq, A. L.
    Li, C.
    Osko, J.
    Malatova, I.
    Franck, D.
    Breustedt, B.
    Leone, D.
    Scott, J.
    Shutt, A.
    Hauck, B.
    Capello, K.
    Perez-Lopez, B.
    Navarro-Amaro, J. F.
    Pliszczyriski, T.
    Fantinova, K.
    Tolmachev, S. Y.
    RADIATION MEASUREMENTS, 2015, 82 : 64 - 73
  • [3] Determination of the 241Am activity in real contaminated slag
    Burda, O.
    Arnold, D.
    Wershofen, H.
    APPLIED RADIATION AND ISOTOPES, 2016, 109 : 452 - 455
  • [4] A MCNP-based calibration method and a voxel phantom for in vivo monitoring of 241Am in skull
    Moraleda, M
    Gómez-Ros, JM
    López, MA
    Navarro, T
    Navarro, JF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 526 (03): : 551 - 559
  • [5] Determination of 241Am/243Am ratios
    Aggarwal, S. K.
    Alamelu, D.
    Shah, P. M.
    Mirashi, N. N.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2007, 273 (03) : 771 - 774
  • [6] Determination of 241Am/243Am ratios
    S. K. Aggarwal
    D. Alamelu
    P. M. Shah
    N. N. Mirashi
    Journal of Radioanalytical and Nuclear Chemistry, 2007, 273 : 771 - 774
  • [7] COUNTING 241AM IN THE BFS HUMAN SKULL PHANTOM ON CONTACT-EVALUATION IN THE HUMAN MONITORING LABORATORY
    Li, Chunsheng
    Hauck, Barry
    Capello, Kevin
    Nogueira, Pedro
    Lopez, Maria A.
    Kramer, Gary H.
    HEALTH PHYSICS, 2015, 108 (03): : 380 - 382
  • [8] A specific voxel phantom for in vivo measurements of 241Am in the knee
    Moraleda, M.
    Lis, M.
    Gomez-Ros, J. M.
    Lopez, M. A.
    RADIATION PROTECTION DOSIMETRY, 2007, 127 (1-4) : 258 - 261
  • [9] Determination of 241Am in Environmental Samples: A Review
    Zhang, Haitao
    Hou, Xiaolin
    Qiao, Jixin
    Lin, Jianfeng
    MOLECULES, 2022, 27 (14):
  • [10] Standardisation of 241Am activity for a key comparison
    Pomme, S.
    Altzitzoglou, T.
    Van Ammel, R.
    Sibbens, G.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2021, 330 (03) : 985 - 996