Frequency of retinal re-detachment after removal of silicone oil Tamponade in cases of proliferative vitreoretinopathy

被引:2
|
作者
Zaheer, Waqas [1 ]
Iqbal, Kashif [1 ]
Usman, Maria [1 ]
机构
[1] LRBT Eye Hosp, Dept Ophthalmologist, Lahore, Pakistan
关键词
Proliferative vitreoretinopathy (PVR); Silicone oil; Retinal detachment; PARS-PLANA VITRECTOMY; SCLERAL BUCKLE; REDETACHMENT; OUTCOMES; RISK;
D O I
10.5455/JPMA.45900
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To determine the frequency of retinal re-detachment (reRD) following silicone oil removal (SOR) in patients who had undergone pars planavitrectomy for treatment of Proliferative vitreoretinopathy (PVR) detachment. Methods: A total of fifty (50) patients with diagnosis of PVR in LRBT hospital Lahore were selected within a duration of 12 months from April-2018 to April-2019 for this prospective observational study. Patients of rhegmatogenous retinal detachment (RD) who underwent vitrectomy using temporary SO tamponade and had completely attached retina at the time of SOR, were included. SOR was done via 3 ports pars plana vitrectomy (PPV) using EVA DORC machine. In 20 patients, scleral buckling (SB) was also done alongwith vitrectomy procedure. After SOR all patients were followed up for 6 months to determine the frequency of retinal re-detachment. Results: There was male pre-dominance with 30 (60%) of total proportion. There were 26 (52%) patients who had a grade C PVR (C1), 18 (32%) had grade B PVR. The retinal re-detachment was found in 2 (4.0%) patients out of 50 patients. In comparison of retinal re-detachment, there was no case of retinal redetachment in patients with SB and re-detachment occurred in 2 (6.6%) out of 30 patients in whom SB was not done (p-value 0.51). Conclusion:The rate of retinal re-detachment after silicone oil removal (SOR) was 4.0%. Implantation of SB at the time of PPV is associated with lower risk of retinal re-detachment after vitrectomy in patients of Proliferative vitreoretinopathy (PVR).
引用
收藏
页码:1404 / 1407
页数:4
相关论文
共 50 条
  • [1] TEMPORARY SILICONE OIL TAMPONADE IN THE MANAGEMENT OF RETINAL-DETACHMENT WITH PROLIFERATIVE VITREORETINOPATHY
    GONVERS, M
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1985, 100 (02) : 239 - 245
  • [2] Facedown Positioning Duration for Silicone Oil Tamponade and the Effect on Retinal Re-detachment
    Zubricky, Ryan
    Platt, Sean
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [3] CHOROIDAL THICKNESS CHANGES AFTER VITRECTOMY WITH SILICONE OIL TAMPONADE FOR PROLIFERATIVE VITREORETINOPATHY RETINAL DETACHMENT
    Odrobina, Dominik
    Golebiewska, Joanna
    Maroszynska, Iwona
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2017, 37 (11): : 2124 - 2129
  • [4] Treatment of proliferative vitreoretinopathy in rhegmatogenous retinal detachment and silicone oil tamponade.
    Berrod, JP
    Sellier, A
    Rozot, P
    Raspiller, A
    [J]. JOURNAL FRANCAIS D OPHTALMOLOGIE, 1996, 19 (02): : 97 - 105
  • [5] Factors of Retinal Re-detachment and Visual Outcome after Intraocular Silicone Oil Removal in Silicone Oil-filled Eyes
    Hu, Shu-Qiong
    Jin, Hui-Yu
    Wang, Yong
    Zhu, Li-Ping
    [J]. CURRENT EYE RESEARCH, 2020, 45 (06) : 742 - 748
  • [6] Re-retinal detachment after silicone oil removal
    Natarajan, Sundaram
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2012, 60 (06) : 501 - 502
  • [8] Vitrectomy with Silicone Oil Tamponade and Single-Dose Intravitreal Methotrexate for Recurrent Retinal Detachment with Proliferative Vitreoretinopathy
    Babel, Adrian
    Chin, Eric K.
    Almeida, David R. P.
    [J]. CASE REPORTS IN OPHTHALMOLOGY, 2022, 13 (03): : 777 - 782
  • [9] Tamponade in surgery for retinal detachment associated with proliferative vitreoretinopathy
    Schwartz, Stephen G.
    Flynn, Harry W., Jr.
    Lee, Wen-Hsiang
    Ssemanda, Elizabeth
    Ervin, Ann-Margret
    [J]. COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2009, (04):
  • [10] Tamponade in surgery for retinal detachment associated with proliferative vitreoretinopathy
    Schwartz, Stephen G.
    Flynn, Harry W., Jr.
    Lee, Wen-Hsiang
    Wang, Xue
    [J]. COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2014, (02):