Predicting objective function weights from patient anatomy in prostate IMRT treatment planning

被引:46
|
作者
Lee, Taewoo [1 ]
Hammad, Muhannad [1 ]
Chan, Timothy C. Y. [1 ,2 ]
Craig, Tim [3 ,4 ]
Sharpe, Michael B. [2 ,3 ,4 ]
机构
[1] Univ Toronto, Dept Mech & Ind Engn, Toronto, ON M5S 3G8, Canada
[2] Techna Inst Advancement Technol Hlth, Toronto, ON M5G 1P5, Canada
[3] UHN Princess Margaret Canc Ctr, Radiat Med Program, Toronto, ON M5T 2M9, Canada
[4] Univ Toronto, Dept Radiat Oncol, Toronto, ON M5S 3S2, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
multicriteria IMRT treatment planning; inverse optimization; prostate cancer treatment; CONVEX PARETO SURFACES; OPTIMIZATION; INTENSITY; ALGORITHM; GEOMETRY;
D O I
10.1118/1.4828841
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Intensity-modulated radiation therapy (IMRT) treatment planning typically combines multiple criteria into a single objective function by taking a weighted sum. The authors propose a statistical model that predicts objective function weights from patient anatomy for prostate IMRT treatment planning. This study provides a proof of concept for geometry-driven weight determination. Methods: A previously developed inverse optimization method (IOM) was used to generate optimal objective function weights for 24 patients using their historical treatment plans (i.e., dose distributions). These IOM weights were around 1% for each of the femoral heads, while bladder and rectum weights varied greatly between patients. A regression model was developed to predict a patient's rectum weight using the ratio of the overlap volume of the rectum and bladder with the planning target volume at a 1 cm expansion as the independent variable. The femoral head weights were fixed to 1% each and the bladder weight was calculated as one minus the rectum and femoral head weights. The model was validated using leave-one-out cross validation. Objective values and dose distributions generated through inverse planning using the predicted weights were compared to those generated using the original IOM weights, as well as an average of the IOM weights across all patients. Results: The IOM weight vectors were on average six times closer to the predicted weight vectors than to the average weight vector, using l(2) distance. Likewise, the bladder and rectum objective values achieved by the predicted weights were more similar to the objective values achieved by the IOM weights. The difference in objective value performance between the predicted and average weights was statistically significant according to a one-sided sign test. For all patients, the difference in rectum V54.3 Gy, rectum V70.0 Gy, bladder V54.3 Gy, and bladder V70.0 Gy values between the dose distributions generated by the predicted weights and IOM weights was less than 5 percentage points. Similarly, the difference in femoral head V54.3 Gy values between the two dose distributions was less than 5 percentage points for all but one patient. Conclusions: This study demonstrates a proof of concept that patient anatomy can be used to predict appropriate objective function weights for treatment planning. In the long term, such geometry-driven weights may serve as a starting point for iterative treatment plan design or may provide information about the most clinically relevant region of the Pareto surface to explore. (C) 2013 American Association of Physicists in Medicine.
引用
下载
收藏
页数:9
相关论文
共 50 条
  • [1] Predicting Objective Function Weights for IMRT Prostate Treatment Planning Using Patient Anatomy
    Lee, T.
    Hammad, M.
    Chan, T.
    Craig, T.
    Sharpe, M.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [2] Models for predicting objective function weights in prostate cancer IMRT
    Boutilier, Justin J.
    Lee, Taewoo
    Craig, Tim
    Sharpe, Michael B.
    Chan, Timothy C. Y.
    MEDICAL PHYSICS, 2015, 42 (04) : 1586 - 1595
  • [3] Prostate Cancer Treatment Planning: Sensitivity and Representative Objective Function Weights
    Goli, A.
    Boutilier, J. J.
    Craig, T.
    Sharpe, M. B.
    Chan, T. C. Y.
    MEDICAL PHYSICS, 2016, 43 (06) : 3803 - 3803
  • [4] Determining Objective Function Weights in Prostate IMRT Using Inverse Optimization
    Chan, T. C. Y.
    Lee, T.
    Craig, T.
    Sharpe, M. B.
    MEDICAL PHYSICS, 2011, 38 (06) : 3687 - +
  • [5] A Logistic Regression Model to Predict Objective Function Weights in Prostate Cancer IMRT
    Boutilier, J.
    Chan, T.
    Craig, T.
    Lee, T.
    Sharpe, M.
    MEDICAL PHYSICS, 2014, 41 (06) : 395 - +
  • [6] Multi-objective IMRT treatment planning
    Craft, D. L.
    Halabi, T.
    Bortfeld, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S658 - S658
  • [7] The Feasibility of MR-Only IMRT Planning for Prostate Anatomy
    Vaitheeswaran, R.
    Sivaramakrishnan, K. R.
    Kumar, Prashant
    Gattamaneni, Raja
    Kumar, Girish
    MEDICAL PHYSICS, 2016, 43 (06) : 3443 - 3443
  • [8] Predicting the parameters of a prostate IMRT objective function based on dose statistics under fixed parameter settings
    Iu, R.
    Radke, R.
    Happersett, L.
    Chui, C.
    Mageras, G.
    Yan-, J.
    Yorke, E.
    Jackson, A.
    MEDICAL PHYSICS, 2007, 34 (06) : 2482 - 2483
  • [9] Predicting patient specific treatment planning Pareto fronts based on anatomy only
    Van der Bijl, E.
    Wang, Y.
    Petit, S. F.
    Janssen, T.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S93 - S94
  • [10] Treatment outcome-based objective functions for IMRT treatment planning
    El Naqa, I.
    Clark, V. H.
    Chen, Y.
    Vicic, M.
    Khullar, D.
    Shimpi, S.
    Hope, A.
    Bradley, J.
    Deasy, J. O.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S687 - S688