Extensively hydroxyapatite-coated stems in revision hip arthroplasty:: A radiological mid-term follow-up study

被引:0
|
作者
Hernández-Vaquero, D
Suarez-Vazquez, A
Cima-Suarez, M
Garcia-Sandoval, MA
Gava, R
机构
[1] Univ Oviedo, Sch Med, Dept Orthopaed Surg, Oviedo, Spain
[2] Hosp San Agustin, Aviles, Spain
关键词
femoral revision; extensively porous-coated; hydroxyapatite;
D O I
10.1177/112070000501500106
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Femoral revision surgery involves the placement of a stable stem and the regeneration of the damaged bone structure. We retrospectively reviewed 36 cases of femoral revision surgery in which an extensively hydroxyapatite-coated porous stem was implanted with a five-year minimum follow-up. Nine of the cases had type I defects, 12 had type II defects, six had III-A defects and nine had III-B defects. The mean follow-up was 7.7 years (range 5-11). No cases of revision surgery, subsidence or displacement were detected. In 35 cases the integration of the stem had been achieved, the bone structure had been restored and there was no fibrous interface visible between the implant and the bone. The fully hydroxyapatite-coated stems thus proved a valuable alternative for femoral revision surgery in mild and moderate bone defects.
引用
收藏
页码:38 / 45
页数:8
相关论文
共 50 条
  • [1] A Randomized Trial of Hydroxyapatite-Coated Femoral Stems in Total Hip Arthroplasty A 13-Year Follow-Up
    Camazzola, Dan
    Hammond, Terry
    Gandhi, Rajiv
    Davey, J. Roderick
    JOURNAL OF ARTHROPLASTY, 2009, 24 (01): : 33 - 37
  • [2] Comparison of Hydroxyapatite-Coated Stems in Total Hip Arthroplasty after a Minimum 10-Years Follow-up
    Gallo, J.
    Landor, I.
    Cechova, I.
    Jahoda, D.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2008, 75 (05) : 339 - 346
  • [3] Outcomes of Long Tapered Hydroxyapatite-Coated Stems in Revision Total Hip Arthroplasty
    Makani, Amun
    Kim, Tae Won B.
    Kamath, Atul F.
    Garino, Jonathan P.
    Lee, Gwo-Chin
    JOURNAL OF ARTHROPLASTY, 2014, 29 (04): : 827 - 830
  • [4] Clinical and radiological outcome of hydroxyapatite-coated femoral stem in revision hip arthroplasty
    T. Gosens
    E. J. van Langelaan
    International Orthopaedics, 2005, 29 : 219 - 223
  • [5] Clinical and radiological outcome of hydroxyapatite-coated femoral stem in revision hip arthroplasty
    Gosens, T
    van Langelaan, EJ
    INTERNATIONAL ORTHOPAEDICS, 2005, 29 (04) : 219 - 223
  • [6] Revision Hip Arthroplasty with A Modular Cementless Stem: Mid-Term Follow Up
    Jibodh, Stefan R.
    Schwarzkopf, Ran
    Anthony, Shawn G.
    Malchau, Henrik
    Dempsey, Kyle E.
    Estok, Daniel M., II
    JOURNAL OF ARTHROPLASTY, 2013, 28 (07): : 1167 - 1172
  • [7] Extensively hydroxyapatite-coated long femoral stem revision hip arthroplasty: Clinical outcome and survivorship in 11 to 17.5 years follow up
    Hong, Liu Wing
    Yin, Chung Kwong
    Wing, Cheung Kin
    Hing, Chiu Kwok
    Kevin, Ho Ki Wai
    JOURNAL OF ORTHOPAEDICS TRAUMA AND REHABILITATION, 2022, 29 (02)
  • [8] Extensively Coated Non-modular Stem Used in Two-stage Revision for Infected Total Hip Arthroplasty: Mid-term to Long-term Follow-up
    Shen, Bin
    Huang, Qiang
    Yang, Jing
    Zhou, Zong-ke
    Kang, Peng-de
    Pei, Fu-xing
    ORTHOPAEDIC SURGERY, 2014, 6 (02) : 103 - 109
  • [9] Minimal 11-year follow-up of extensively porous-coated stems in femoral revision total hip arthroplasty
    Weeden, SH
    Paprosky, WG
    JOURNAL OF ARTHROPLASTY, 2002, 17 (04): : 134 - 137
  • [10] Survivorship and Radiological Analysis of a Monoblock, Hydroxyapatite-Coated Titanium Stem in Revision Hip Arthroplasty
    Saunders, Paul R. J.
    Shaw, Debbie A.
    Sidharthan, Sijin K.
    Siney, Paul D.
    Young, Stephen K.
    Board, Tim N.
    JOURNAL OF ARTHROPLASTY, 2020, 35 (06): : 1678 - 1685