Motion-preserving, 2-stage transoral and posterior treatment of an unstable Jefferson fracture in a professional football player

被引:3
|
作者
Rodts, Gerald E., Jr. [1 ]
Baum, Griffin R. [1 ]
Stewart, Fermin G. [2 ]
Heller, John G. [1 ]
机构
[1] Emory Univ, Emory Orthopaed & Spine Ctr, Sch Med, 59 Execut Pk South,Ste 3000, Atlanta, GA 30329 USA
[2] Johns Creek ENT, Atlanta, GA USA
关键词
cervical trauma; sports medicine; Jefferson fracture; C-1 (atlas) fracture; transoral approach; motion preserving; open reduction and internal fixation; ORIF; REDUCTION; C1;
D O I
10.3171/2017.6.SPINE17274
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The authors report the case of a patient who suffered a Jefferson fracture during a professional football game. The C-1 (atlas) fracture was widely displaced anteriorly, but the transverse ligament was intact. In an effort to enable a return to play and avoid intersegmental (C1-2) fusion, the patient underwent a transoral approach for open reduction and internal fixation of the fracture. The associated posterior ring fracture displacement widened after this procedure, and a subsequent posterior arthrodesis and fixation of the fracture site was performed 6 months later when the fracture failed to heal with rigid collar immobilization. The approach maintained the normal range of motion at the atlantoaxial and atlantooccipital joints, which would have been sacrificed by an atlantoaxial or occipitocervical fusion, as is traditionally performed. Ultimately, the patient decided not to return to the football field, but this approach could avoid the more significant loss of motion associated with atlantoaxial or occipitocervical fusion for unstable Jefferson fractures.
引用
收藏
页码:149 / 153
页数:5
相关论文
共 5 条
  • [1] Motion-preserving treatment of unstable atlas fracture: transoral anterior C1-ring osteosynthesis using a laminoplasty plate
    Xiaobao Zou
    Beiping Ouyang
    Binbin Wang
    Haozhi Yang
    Su Ge
    Yuyue Chen
    Ling Ni
    Shuang Zhang
    Hong Xia
    Zenghui Wu
    Xiangyang Ma
    BMC Musculoskeletal Disorders, 21
  • [2] Motion-preserving treatment of unstable atlas fracture: transoral anterior C1-ring osteosynthesis using a laminoplasty plate
    Zou, Xiaobao
    Ouyang, Beiping
    Wang, Binbin
    Yang, Haozhi
    Ge, Su
    Chen, Yuyue
    Ni, Ling
    Zhang, Shuang
    Xia, Hong
    Wu, Zenghui
    Ma, Xiangyang
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [3] Motion-preserving C1 lateral mass fixation with compression for unstable Jefferson fracture of the Atlas: technical note
    Beucler, Nathan
    Sellier, Aurore
    Dagain, Arnaud
    NEUROSURGICAL REVIEW, 2024, 47 (01)
  • [4] A Modified 2-Stage Treatment for AO/OTA 43-C1 Pilon Fractures Accompanied by Distal Fibular and Posterior Lip of the Distal Tibia Fracture
    Zheng, Yang
    Zhang, Jiu-Dan
    Shen, Jin-Ming
    Chen, Jun-Jie
    Toy, Lucinda
    Huang, Jie-Feng
    JOURNAL OF FOOT & ANKLE SURGERY, 2020, 59 (05): : 972 - 978
  • [5] One-stage posterior C2 and C3 pedicle screw fixation or combined anterior C2-C3 fusion for the treatment of unstable hangman's fracture
    Liu, Jingchen
    Li, Ye
    Wu, Yuntao
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2013, 5 (03) : 667 - 672