Comparison of a new dead-time correction method and conventional models for SIMS analysis

被引:2
|
作者
Takano, Akio [1 ]
Takenaka, Hisataka [1 ]
Ichimaru, Satoshi [1 ]
Nonaka, Hidehiko [2 ]
机构
[1] NTT Adv Technol Corp, Atsugi, Kanagawa 2430124, Japan
[2] Natl Inst Adv Ind Sci & Technol, Tsukuba, Ibaraki 3058568, Japan
关键词
SIMS; detector; saturation; intermediate dead-time model;
D O I
10.1002/sia.5004
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Recently, secondary ion mass spectrometry (SIMS) has been used in the analysis of not only impurities but also matrix elements, thus requiring a wide dynamic range for SIMS analysis. However, SIMS detectors, which are mostly used in pulse counting systems, have difficulties with detector saturation. In this paper, we investigate whether a dead-time model that was developed for X-ray measurement is applicable for SIMS analysis. We then compare a new correction method with conventional correction methods for detector saturation in SIMS analysis. We report that the new method can better correct the intensity in regions of higher intensity than that achieved by conventional methods. Copyright (c) 2012 John Wiley & Sons, Ltd.
引用
收藏
页码:1287 / 1293
页数:7
相关论文
共 50 条
  • [1] ERRORS IN DEAD-TIME CORRECTION WITH EDS ANALYSIS
    BLOOMFIELD, DJ
    LOVE, G
    SCOTT, VD
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1982, (61): : 181 - 182
  • [2] ASYMPTOTIC METHOD OF DEAD-TIME CORRECTION IN POISSONIAN DISTRIBUTION
    CARLONI, F
    CORBERI, A
    MARSEGUERRA, M
    PORCEDDU, CM
    NUCLEAR INSTRUMENTS & METHODS, 1970, 78 (01): : 70 - +
  • [3] RATEMETER WITH DEAD-TIME CORRECTION
    JANKA, K
    KULMALA, V
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1983, 54 (11): : 1573 - 1574
  • [4] ON THE DEAD-TIME CORRECTION OF ION COUNTING SYSTEMS DURING GATED RASTER SIMS MEASUREMENTS
    TRAXLMAYR, U
    RIEDLING, K
    ZINNER, E
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1984, 61 (03): : 261 - 276
  • [5] Measurement of the dead-time correction in γ-ray spectrometry by the pulser method
    Korun, M.
    Martincic, R.
    Journal of Trace and Microprobe Techniques, 1996, 14 (01):
  • [6] PRACTICAL PROBLEMS WITH DEAD-TIME CORRECTION
    FULTON, RR
    HUTTON, BF
    DYER, IA
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1983, 13 (06): : 655 - 656
  • [7] DEAD-TIME CORRECTION USING A TIMER
    PONIKVAR, D
    JEGLIC, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1994, 88 (03): : 308 - 312
  • [8] DEAD-TIME CORRECTION IN MULTICHANNEL ANALYZERS
    SIMMER, J
    NUCLEAR INSTRUMENTS & METHODS, 1971, 93 (01): : 131 - &
  • [9] A Dead-Time Correction Method for Multiple Gamma-ray Detection
    Kimura, A.
    Furutaka, K.
    Goko, S.
    Harada, H.
    Igashira, M.
    Kamiyama, T.
    Katabuchi, T.
    Kin, T.
    Kino, K.
    Kitatani, F.
    Kiyanagi, Y.
    Koizumi, M.
    Mizumoto, M.
    Nakamura, S.
    Ohta, M.
    Oshima, M.
    Toh, Y.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 138 - +
  • [10] DEAD-TIME CORRECTION IN NUCLEONIC COUNTER SYSTEMS
    TAYLOR, D