Detection of hepatitis C virus by PCR in second-generation enzyme immunoassay-seropositive blood donors by using matched pairs of fresh frozen plasma and pilot tube sera

被引:7
|
作者
Krajden, M
Zhao, J
Bourke, C
Scalia, V
Gill, P
Lau, W
机构
[1] UNIV TORONTO,DEPT MICROBIOL,TORONTO,ON M5G 1A1,CANADA
[2] CANADIAN RED CROSS SOC,NATL TESTING LAB,OTTAWA,ON K1G 4J5,CANADA
[3] CANADIAN RED CROSS,TORONTO CTR,TORONTO,ON M5G 2M1,CANADA
关键词
D O I
10.1128/JCM.34.9.2191-2195.1996
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Between April 1993 and March 1995, 429 of 334,454 (0.13%) blood donations at the Toronto Centre of the Canadian Red Cross were reactive for hepatitis C virus (HCV) by second-generation enzyme immunoassay (EIA-2). Of the 429 EIA-2-positive donations, 189 (44%), 138 (32%), and 102 (24%) were positive, indeterminate, and negative by Second-Generation Recombinant Immunoblot Assay (RIBA-2). To assess HCV viremia and minimize the risk that specimen handling affected PCR-based detection, the qualitative AMPLICOR HCV test was performed on both pilot tube sera (PTS) and the corresponding fresh frozen plasma (FFP) from 294 EIA-2-reactive donations. AMPLICOR PCR results for PTS and FFP were 100% concordant and were confirmed by nested HCV PCR for 27 of 294 donations. The AMPLICOR HCV test was positive for 127 of 140 (91%) of RIBA-2-positive donations (81, 91, and 96% of donations with two, three, and four reactive bands, respectively), 5 of 88 (5.7%) indeterminate donations, and 0 of 66 (0%) RIBA-2-negative donations. The Third-Generation Recombinant Immunoblot Assay (RIBA-3) was performed on RIBA-2-negative, -indeterminate, and -positive, PCR-negative donations. RIBA-3 demonstrated enhanced specificity and resolved 18 of 88 (20%) of RIBA-2-indeterminate samples as HCV antibody positive. The study demonstrates that PTS are as suitable as FFP for PCR-based detection of HCV and can be used to determine if EIA-2-reactive blood donors are viremic at the time of donation.
引用
收藏
页码:2191 / 2195
页数:5
相关论文
共 3 条
  • [1] Sensitivity of second-generation enzyme immunoassay for detection of hepatitis C virus infection among oncology patients
    de Oliveira, AM
    White, KL
    Beecham, BD
    Leschinsky, DP
    Foley, BP
    Dockter, J
    Giachetti, C
    Safranek, TJ
    JOURNAL OF CLINICAL VIROLOGY, 2006, 35 (01) : 21 - 25
  • [2] DETECTION OF HEPATITIS-C VIRUS (HCV) BY POLYMERASE CHAIN-REACTION (PCR) IN FROZEN PLASMA COMPONENTS AND PILOT TUBE SAMPLES
    LAU, W
    WRIGHT, L
    HERST, R
    ZHAO, J
    KRAJDEN, M
    SCALIA, V
    GILL, P
    TRANSFUSION, 1994, 34 (10) : S33 - S33
  • [3] Use of third-generation hepatitis C virus (HCV) enzyme immunoassay (EIA) to resolve second-generation HCV EIA-reactive and second-generation recombinant immunoblot assay-indeterminate blood samples: data to support current Food and Drug Administration guidance on HCV lookback
    Busch, MP
    Tobler, LH
    Tegtmeier, G
    Polito, A
    Quan, S
    Hirschler, NV
    Dockter, J
    Giachetti, C
    Mimms, L
    TRANSFUSION, 2000, 40 (01) : 10 - 14