Determination of dexamethasone by flow-injection chemiluminescence method using capped CdS quantum dots

被引:9
|
作者
Khataee, Alireza [1 ]
Hasanzadeh, Aliyeh [1 ]
Lotfi, Roya [1 ]
Pourata, Rahmatollah [2 ]
Joo, Sang Woo [3 ]
机构
[1] Univ Tabriz, Dept Appl Chem, Res Lab Adv Water & Wastewater Treatment Proc, Fac Chem, Tabriz 5166616471, Iran
[2] Univ Zanjan, Dept Chem, Fac Sci, Zanjan 4537138791, Iran
[3] Yeungnam Univ, Sch Mech Engn, Kyongsan 712749, South Korea
关键词
CdS quantum dots; Chemiluminescence; Dexamethasone; Flow injection; Nanocatalyst; ACIDIC POTASSIUM-PERMANGANATE; ENHANCED CHEMILUMINESCENCE; CUO NANOSHEETS; LIQUID-CHROMATOGRAPHY; L-CYSTEINE; SYSTEM; CDTE; WATER; PHARMACEUTICALS; ASSAY;
D O I
10.1016/j.saa.2015.05.047
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
L-Cysteine capped CdS quantum dots (QDs) were synthesized through a facile hydrothermal method and characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), photoluminescence (PL) and UV-Vis spectroscopy. The light emitted from KMnO4-L-cysteine capped CdS QDs reaction in acidic medium was applied as a simple and sensitive chemiluminescence (CL) system for determination of dexamethasone. The CL intensity of KMnO4-L-cysteine capped CdS QDs CL system was remarkably enhanced in the presence of dexamethasone. Under optimum experimental conditions, the enhanced CL intensity was related to dexamethasone concentration in the range of 0.004-25.0 mg L-1, with the detection limit (3 sigma) of 0.0013 mg L-1. The analytical applicability of the proposed CL system was assessed by determining dexamethasone in spiked environmental water samples and pharmaceutical formulation. The analytical performances of proposed flow-injection CL method for the determination of dexamethasone were compared with those obtained by corona discharge ionization ion mobility spectrometry (CD-IMS) method. The proposed CL system exhibits a higher sensitivity and precision than the CD-IMS method for the determination of dexamethasone. (c) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:63 / 71
页数:9
相关论文
共 50 条
  • [1] A novel flow-injection chemiluminescence method for determination of baclofen using L-cysteine capped CdS quantum dots
    Khataee, Alireza
    Hasanzadeh, Aliyeh
    Iranifam, Mortaza
    Joo, Sang Woo
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 215 : 272 - 282
  • [2] Determination of metronidazole by a flow-injection chemiluminescence method using ZnO-doped carbon quantum dots
    Yan Zheng-yu
    Xiao An
    Lu Hua
    Liu Zhen
    Chen Jian-qiu
    NEW CARBON MATERIALS, 2014, 29 (03) : 216 - 224
  • [3] Determination of ofloxacin using a chemiluminescence flow-injection method
    Rao, Y
    Tong, Y
    Zhang, XR
    Luo, G
    Baeyens, WRG
    ANALYTICA CHIMICA ACTA, 2000, 416 (02) : 227 - 230
  • [4] Flow-injection chemiluminescence analysis for sensitive determination of atenolol using cadmium sulfide quantum dots
    Khataee, Alireza
    Lotfi, Roya
    Hasanzadeh, Aliyeh
    Iranifam, Mortaza
    Joo, Sang Woo
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2016, 157 : 88 - 95
  • [5] Flow-injection chemiluminescence of the luminol-potassium periodate system enhanced by TGA-capped CdTe quantum dots for the determination of theophylline
    Zhou, Min
    Chen, Qiqi
    Wang, Ailian
    Li, Juanhua
    Ma, Yongjun
    LUMINESCENCE, 2019, 34 (07) : 673 - 679
  • [6] Determination of ascorbic acid by flow-injection chemiluminescence method
    Yu, J.
    Zhang, C.
    Tan, Y.
    Ge, S.
    Dai, P.
    Zha, Y.
    LUMINESCENCE, 2008, 23 (02) : 107 - 107
  • [7] Flow-injection chemiluminescence method for the determination of hydrocortisone and progesterone
    Li, HN
    Ci, YX
    APPLIED SPECTROSCOPY, 1997, 51 (10) : 1484 - 1487
  • [8] DETERMINATION OF TETRACYCLINE AND OXYTETRACYCLINE BY FLOW-INJECTION CHEMILUMINESCENCE METHOD
    唐玉海
    韩小年
    于春玲
    孙媛媛
    姚宏
    Academic Journal of Xi'an Jiaotong University, 2006, (02) : 136 - 138
  • [9] Chemiluminescence determination of ultramicro DNA with a flow-injection method
    Chen, H
    Zhou, M
    Jin, XY
    Song, YM
    Zhang, ZY
    Ma, YJ
    ANALYTICA CHIMICA ACTA, 2003, 478 (01) : 31 - 36
  • [10] SELECTIVE DETERMINATION OF TRIPHOSPHONUCLEOTIDE BY A FLOW-INJECTION CHEMILUMINESCENCE METHOD
    OHNO, Y
    HOBO, T
    TAMURA, R
    ISHII, M
    BUNSEKI KAGAKU, 1993, 42 (03) : 183 - 190