Diagnostic accuracy of lugol chromoendoscopy in the oesophagus in patients with head and neck cancer

被引:1
|
作者
Carvalho, Rita [1 ]
Areia, Miguel [1 ]
Brito, Daniel [1 ]
Saraiva, Sandra [1 ]
Alves, Susana [1 ]
Cadime, Ana Teresa [1 ]
机构
[1] Coimbra Portuguese Inst Oncol, Gastroenterol Unit, P-3001651 Coimbra, Portugal
关键词
Oesophageal cancer; Squamous cell carcinoma; Lugol solution; Gastrointestinal Endoscopy; Chromoendoscopy; SQUAMOUS-CELL CARCINOMA; VOIDING LESIONS; ENDOSCOPY; COUNTRIES; DYSPLASIA; TRENDS; SPRAY;
D O I
暂无
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and aim: patients with head and neck squamous cell malignancies have a higher risk of oesophageal squamous cell carcinomas. Lugol chromoendoscopy in oesophagus is a simple technique with a high diagnostic yield in premalignant lesions. The objective was to analyze its diagnostic accuracy in dysplasia and carcinoma of the oesophagus in high-risk patients. Methods: prospective study from April/2008 to January/2012 using lugol chromoendoscopy with biopsies of suspicious lugol voiding areas >= 5 mm. Patients with head and neck malignancies were included, except the ones with iodine allergy, oesophageal varices and contra-indications to standard endoscopy. The reference method was histopathology. Results: 89 patients were enrolled (mean age 62.8 +/- 13.3 years, 87 % men). Primary tumour was located in oropharynx in 37 (41.6 %), in oral cavity in 29 (32.6 %) and in the larynx in 23 (25.8 %) cases. 40.4% patients had previous treatments and 87 % reported alcohol or tobacco addition. All exams performed without anaesthesia or complications. Nine suspicious lugol voiding areas were observed and biopsied. Histopathological analysis revealed high-grade dysplasia in 2 (2.2 %) and inflammation or normal findings in the others. The sensitivity and specificity for detecting high-grade dysplasia were 100 % and 92 % (95 % CI 87-97), respectively. Diagnostic accuracy of the test was 92 % (95 % CI: 86-98). Conclusion: lugol staining of the oesophagus during endoscopy seems to be a feasible, safe and justified procedure in high-risk population as it enhances the detection of premalignant lesions.
引用
收藏
页码:79 / 83
页数:5
相关论文
共 50 条
  • [1] Detection of esophageal cancer using chromoendoscopy with Lugol dye method in head and neck cancer patients
    Lee, S
    Chun, HJ
    Jeen, YT
    Lee, G
    Kim, KH
    Lee, HS
    Song, CW
    Lee, SW
    Choi, JH
    Kim, CD
    Ryu, HS
    Hyun, JH
    GASTROINTESTINAL ENDOSCOPY, 1999, 49 (04) : AB105 - AB105
  • [2] Lugol's dye spray chromoendoscopy establishes early diagnosis of esophageal cancer in patients with primary head and neck cancer
    Hashimoto, CL
    Iriya, K
    Baba, ER
    Navarro-Rodriguez, T
    Zerbini, MC
    Eisig, JN
    Barbuti, R
    Chinzon, D
    Moraes-Filho, JPP
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2005, 100 (02): : 275 - 282
  • [3] Diagnostic accuracy of methylene blue guided chromoendoscopy in patients with suspicion of dysplastic Barrett's oesophagus
    Bisschops, Raf
    Demedts, Ingrid
    Ectors, Nadine
    Geboes, Karel
    Tack, Jan F.
    Janssens, Jozef
    Rutgeerts, Paul J.
    GASTROINTESTINAL ENDOSCOPY, 2008, 67 (05) : AB173 - AB173
  • [4] Diagnostic accuracy of probe-based confocal laser endomicroscopy in Lugol-unstained esophageal superficial lesions of patients with head and neck cancer
    Safatle-Ribeiro, Adriana Vaz
    Baba, Elisa Ryoka
    Faraj, Sheila Friedrich
    Rios, Juliana Trazzi
    De Lima, Marcelo Simas
    Martins, Bruno Costa
    Geiger, Sebastian Naschold
    Pennacchi, Caterina
    Gusman, Carla
    Kawaguti, Fbio Shiguehissa
    Uemura, Ricardo Sato
    de Melo, Evandro Sobroza
    Ribeiro, Ulysses, Jr.
    Maluf-Filho, Fauze
    GASTROINTESTINAL ENDOSCOPY, 2017, 85 (06) : 1195 - 1207
  • [5] NARROW BAND IMAGING ENDOSCOPY VERSUS LUGOL CHROMOENDOSCOPY IN SCREENING FOR ESOPHAGEAL CANCER AMONG PATIENTS WITH HEAD AND NECK CANCERS: A RANDOMIZED TRIAL
    Chaber-Ciopinska, Anna
    Kaminski, Michal F.
    Wieszczy, Paulina
    Bielasik, Andrzej
    Bugajski, Marek
    Januszewicz, Wladyslaw
    Kiprian, Dorota
    Jarzabski, Andrzej
    Rolski, Wojciech
    Niemiec, Milena
    Mroz, Andrzej
    Kawecki, Andrzej
    Regula, Jaroslaw
    GASTROINTESTINAL ENDOSCOPY, 2019, 89 (06) : AB93 - AB94
  • [6] A prospective comparative study of narrow-band imaging, Lugol's chromoendoscopy and conventional endoscopy for the detection of esophageal cancer in patients with head and neck cancer
    Lee, I-lin
    Wu, Cheng-Shyong
    Hwang, Tzer-zen
    Chen, Wen-cheng
    Tung, Shui-yi
    Chuang, Chia-sheng
    Wei, Kuo-ling
    GASTROENTEROLOGY, 2007, 132 (04) : A168 - A168
  • [7] Early detection of esophageal second primary tumors using Lugol chromoendoscopy in patients with head and neck cancer: A systematic review and meta-analysis
    Bugter, Oisin
    van de Ven, Steffi E. M.
    Hardillo, Jose A.
    Bruno, Marco J.
    Koch, Arjun D.
    de Jong, Robert J. Baatenburg
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2019, 41 (04): : 1122 - 1130
  • [8] THE DIAGNOSTIC-ACCURACY OF PHARYNGOESOPHAGRAM COMPARED TO ESOPHAGOSCOPY IN PATIENTS WITH HEAD AND NECK-CANCER
    GROSSMAN, TW
    KITA, MS
    TOOHILL, RJ
    LARYNGOSCOPE, 1987, 97 (09): : 1030 - 1032
  • [9] Lugol chromoendoscopy for esophageal squamous cell cancer
    Inoue, H
    Rey, JF
    Lightdale, C
    ENDOSCOPY, 2001, 33 (01) : 75 - 79
  • [10] Lugol chromoendoscopy for esophageal squamous cell cancer - Mailbox
    Ponchon, T
    ENDOSCOPY, 2001, 33 (01) : 79 - 79