X-ray vector radiography for bone micro-architecture diagnostics

被引:49
|
作者
Potdevin, Guillaume [1 ,2 ]
Malecki, Andreas [1 ,2 ]
Biernath, Thomas [1 ,2 ]
Bech, Martin [1 ,2 ]
Jensen, Torben H. [3 ]
Feidenhans'l, Robert [3 ]
Zanette, Irene [4 ]
Weitkamp, Timm [5 ]
Kenntner, Johannes [6 ]
Mohr, Juergen [6 ]
Roschger, Paul [7 ,8 ]
Kerschnitzki, Michael [9 ]
Wagermaier, Wolfgang [9 ]
Klaushofer, Klaus [7 ,8 ]
Fratzl, Peter [9 ]
Pfeiffer, Franz [1 ,2 ]
机构
[1] Tech Univ Munich, Dept Phys, D-85748 Garching, Germany
[2] Tech Univ Munich, Inst Med Engn, D-85748 Garching, Germany
[3] Univ Copenhagen, Niels Bohr Inst, DK-2100 Copenhagen, Denmark
[4] European Synchrotron Radiat Facil, F-38043 Grenoble, France
[5] Synchrotron Soleil, F-91192 Gif Sur Yvette, France
[6] Inst Microstruct Technol, Karlsruhe Inst Technol, D-76021 Karlsruhe, Germany
[7] Hanusch Hosp WGKK, Ludwig Boltzmann Inst Osteol, A-1140 Vienna, Austria
[8] Hanusch Hosp, Dept Med 1, AUVA Trauma Ctr Meidling, A-1140 Vienna, Austria
[9] Max Planck Inst Colloids & Interfaces, Dept Biomat, D-14424 Potsdam, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2012年 / 57卷 / 11期
基金
欧洲研究理事会;
关键词
GRATING INTERFEROMETER; TRABECULAR BONE; OSTEOPOROSIS; ARCHITECTURE; SCATTERING; DISEASE;
D O I
10.1088/0031-9155/57/11/3451
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The understanding of large biophysical systems at the systems level often depends on a precise knowledge of their microstructure. This is difficult to obtain, especially in vivo, because most imaging methods are either limited in terms of achievable field of view, or make use of penetrating ionizing radiations such as x-rays, in which case the resolution is severely limited by the deposited dose. Here, we describe a new method, x-ray vector radiography (XVR), which yields various types of information about the local orientation, anisotropy and average size of the sample microstructures. We demonstrate the feasibility by showing first experimental XVRs of human vertebra bone samples, giving information on the trabecular structures even with a pixel resolution of half a millimetre, much larger than the structures themselves. This last point is critical for the development of low-dose measurement methods which will allow for in vivo studies and potentially in the future for new medical diagnostics methods of bone metabolic disorder diseases such as osteoporosis.
引用
收藏
页码:3451 / 3461
页数:11
相关论文
共 50 条
  • [1] Correlation of X-Ray Vector Radiography to Bone Micro-Architecture
    Schaff, Florian
    Malecki, Andreas
    Potdevin, Guillaume
    Eggl, Elena
    Noel, Peter B.
    Baum, Thomas
    Garcia, Eduardo Grande
    Bauer, Jan S.
    Pfeiffer, Franz
    SCIENTIFIC REPORTS, 2014, 4
  • [2] Correlation of X-Ray Vector Radiography to Bone Micro-Architecture
    Florian Schaff
    Andreas Malecki
    Guillaume Potdevin
    Elena Eggl
    Peter B. Noël
    Thomas Baum
    Eduardo Grande Garcia
    Jan S. Bauer
    Franz Pfeiffer
    Scientific Reports, 4
  • [3] X-ray vector radiography of a human hand
    Jud, Christoph
    Braig, Eva
    Dierolf, Martin
    Eggl, Elena
    Guenther, Benedikt
    Achterhold, Klaus
    Gleich, Bernhard
    Rummeny, Ernst
    Noel, Peter
    Pfeiffer, Franz
    Muenzel, Daniela
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [4] Radiation affects the micro-architecture of bone
    Hamilton, SA
    Pecaut, MJ
    Gridley, DS
    Obenaus, A
    Bateman, TA
    JOURNAL OF BONE AND MINERAL RESEARCH, 2005, 20 (09) : S168 - S168
  • [5] Morphological Characterisation of Unstained and Intact Tissue Micro-architecture by X-ray Computed Micro- and Nano-Tomography
    Lucy A. Walton
    Robert S. Bradley
    Philip J. Withers
    Victoria L. Newton
    Rachel E. B. Watson
    Clare Austin
    Michael J. Sherratt
    Scientific Reports, 5
  • [6] Morphological Characterisation of Unstained and Intact Tissue Micro-architecture by X-ray Computed Micro- and Nano-Tomography
    Walton, Lucy A.
    Bradley, Robert S.
    Withers, Philip J.
    Newton, Victoria L.
    Watson, Rachel E. B.
    Austin, Clare
    Sherratt, Michael J.
    SCIENTIFIC REPORTS, 2015, 5
  • [7] X-ray Vector Radiography Imaging for Biomedical Applications
    Potdevin, Guillaume
    Malecki, Andreas
    Biernath, Thomas
    Bech, Martin
    Pfeiffer, Franz
    INTERNATIONAL WORKSHOP ON X-RAY AND NEUTRON PHASE IMAGING WITH GRATINGS, 2012, 1466 : 90 - 96
  • [8] X-RAY MICRO-RADIOGRAPHY OF BIOLOGICAL SPECIMENS
    EHRENBERG, W
    SPEAR, WE
    NATURE, 1951, 168 (4273) : 513 - 514
  • [9] X-ray micro-radiography and microscopy of seeds
    Sykora, Viktor
    Zemlicka, Jan
    Krejci, Frantisek
    Jakubek, Jan
    SCIENCE, 2013, 339 (6119) : 511 - 511
  • [10] Relationships between bone mass and micro-architecture at the mandible and iliac bone in edentulous subjects: a dual X-ray absorptiometry, computerised tomography and microcomputed tomography study
    Bodic, Francois
    Amouriq, Yves
    Gayet-Delacroix, Marie
    Maugars, Yves
    Hamel, Luc
    Basle, Michel F.
    Chappard, Daniel
    GERODONTOLOGY, 2012, 29 (02) : E585 - E594