Conjunctival advancement versus nonincisional treatment for late-onset glaucoma filtering bleb leaks

被引:57
|
作者
Burnstein, AL [1 ]
WuDunn, D [1 ]
Knotts, SL [1 ]
Catoira, Y [1 ]
Cantor, LB [1 ]
机构
[1] Indiana Univ, Dept Ophthalmol, Indianapolis, IN 46202 USA
关键词
D O I
10.1016/S0161-6420(01)00838-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To compare the outcomes of conjunctival advancement and nonincisional management of late-onset glaucoma filtering bleb leak. Design: Retrospective, nonrandomized, comparative interventional trial. Participants: Fifty-one eyes of 48 persons who underwent management of late-onset glaucoma filtering bleb leak from December 1986 through December 1999 were included. Thirty-seven eyes were included in the nonincisional treatment group (aqueous suppression with lubrication or patching, bandage contact lenses, cyanoacrylate glue, autologous blood injection, or a combination thereof) and 34 eyes were included in the surgical revision group (conjunctival advancement with preservation of the preexisting bleb). Twenty eyes underwent nonincisional treatment before surgical revision and were included in each treatment group. Methods: Retrospective chart review of bleb leaks occurring at least 2 months after trabeculectomy. Successful treatment was defined as the resolution of the bleb leak, a final intraocular pressure (IOP) of 21 mmHg or less, and no significant complications such as blebitis, endophthalmitis, or bleb dysesthesia requiring a bleb revision. Main Outcome Measures. Cumulative success of closure of the filtering bleb leak, complications resulting from the intervention, IOP before and after treatment, and number of glaucoma medications before and after treatment. Results: The Kaplan-Meier cumulative probability of success at 12 and 24 months were 0.45 and 0.42, respectively, for the nonincisional treatment group and 0.80 and 0.80, respectively, for the surgical revision group. The overall difference between the cumulative success of surgical and nonincisional treatment was statistically significant (P = 0.0001, log-rank test). In the nonincisional treatment group, only 20 of 37 eyes (54%) achieved initial sealing of the bleb leak after the treatment, and of those, almost half (8/20) eventually failed. Reasons for failure included persistent or recurrent leak (n = 21), blebitis or endophthalmitis (n = 6, including 4 with persistent leak), and bleb clysesthesia (n = 2). All eyes in the surgical group achieved closure of the leak, however 7 eventually failed because of leak recurrence (n = 2), elevated IOP (n = 3), or bleb clysesthesia (n 2), and 11 required additional glaucoma medications. Conclusions: Patients with late bleb leaks managed with conjunctival advancement were more likely to have successful outcomes and less likely to have serious intraocular infections than those managed more conservatively. Ophthalmology 2002;109:71-75 (C) 2002 by the American Academy of Ophthalmology.
引用
收藏
页码:71 / 75
页数:5
相关论文
共 50 条
  • [1] Conjunctival advancement for late-onset filtering bleb leaks - Indications and outcomes
    Budenz, DL
    Chen, PP
    Weaver, YK
    ARCHIVES OF OPHTHALMOLOGY, 1999, 117 (08) : 1014 - 1019
  • [2] Conjunctival advancement versus conservative treatment for late filtering bleb leaks.
    Burnstein, A
    WuDunn, D
    Knotts, S
    Cantor, LB
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S82 - S82
  • [3] Late-onset bleb leaks after glaucoma filtering surgery
    Jee, J
    Greenfield, DS
    Liebmann, JM
    Patelska, B
    Ishikawa, H
    Ritch, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 4980 - 4980
  • [4] Late-onset bleb leaks after glaucoma filtering surgery
    Greenfield, DS
    Liebmann, JM
    Jee, J
    Ritch, R
    ARCHIVES OF OPHTHALMOLOGY, 1998, 116 (04) : 443 - 447
  • [5] Amniotic membrane graft for late-onset glaucoma filtering leaks
    Kee, C
    Hwang, JM
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2002, 133 (06) : 834 - 835
  • [6] Efficacy of autologous conjunctival flap on repairing the late-onset filtering bleb leakage
    Xu, Jian-Gang
    Zhong, Jing
    Yang, Yang-Fan
    Lin, Ming-Kai
    Liu, Xing
    Yu, Min-Bin
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2018, 11 (04) : 601 - 606
  • [7] Efficacy of autologous conjunctival flap on repairing the late-onset filtering bleb leakage
    Jian-Gang Xu
    Jing Zhong
    Yang-Fan Yang
    Ming-Kai Lin
    Xing Liu
    Min-Bin Yu
    International Journal of Ophthalmology, 2018, (04) : 601 - 606
  • [8] Outcomes of Surgical Bleb Revision for Late-onset Bleb Leaks After Trabeculectomy
    Lin, Albert P.
    Chung, Juliet E.
    Zhang, Kevin S.
    Chang, Michelle M.
    Orengo-Nania, Silvia
    Gross, Ronald L.
    Chang, Peter T.
    JOURNAL OF GLAUCOMA, 2013, 22 (01) : 21 - 25
  • [9] The incidence and outcome of late-onset bleb leaks following trabeculectomy with mitomycin
    DeBry, CPW
    Perkins, TW
    Heatley, GA
    Kaufman, PL
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S663 - S663
  • [10] Autologous blood injection for late-onset filtering bleb leak
    Burnstein, A
    WuDunn, D
    Ishii, Y
    Jonescu-Cuypers, C
    Cantor, LB
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2001, 132 (01) : 36 - 40