Effect of chemical cleaning conditions on the flux recovery of fouled membrane

被引:15
|
作者
Woo, Yun Chul [1 ]
Lee, Jeong Jun [1 ]
Oh, Jin Seok [1 ]
Jang, Hyun Ji [1 ]
Kim, Han Seung [1 ]
机构
[1] Myongji Univ, Dept Environm Engn & Energy, Yongin 449728, Kyonggi Do, South Korea
关键词
Chemical cleaning; Fouling; Hollow fiber membrane; Microfiltration; Flux; Recovery rate; NATURAL ORGANIC-MATTER; NANOFILTRATION MEMBRANES; SURFACE-PROPERTIES; REVERSE-OSMOSIS; POTABLE WATER; ULTRAFILTRATION; MICROFILTRATION; OPTIMIZATION;
D O I
10.1080/19443994.2013.768754
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Flux recovery through chemical cleaning was investigated using small-sized membrane modules for application in drinking water treatment using river water as feed. This study focused on the causes of membrane fouling by evaluating the cleaning efficiency with several chemical agents at various conditions. Sodium hypochlorite and sodium hydroxide as basic chemicals, and citric acid, nitric acid, oxalic acid, and sulfuric acid as acidic chemicals were used in the experiment. Each chemical was prepared at concentrations of 0.1, 1, 3, and 5%. The mini-module was made of four strings of polyvinylidene fluoride hollow fibers with pore diameter of 0.038 mu m. Flux was tested at constant pressure of 0.5bar. The experiment was operated at the temperature range of 18.1-25.3 degrees C. To compare the effect of water temperature, cleaning test was performed at the range of 0-5 degrees C. Also, the effect of combination of chemicals was tested with cleaning sequences of base-acid-base and acid-base-acid. The surface characteristics of the membrane were also investigated using Scanning electron microscopy and tensile strength analyses. Prior to the chemical cleaning, flux of fouled membrane was measured using deionized water. Duration of chemical cleaning was set at 30min, 1, 2, and 4h, and then, the flux was checked. For the control, pure water flux was measured using virgin hollow fiber membranes. Among the chemicals, sodium hypochlorite showed the highest flux recovery rate of 44.0% at 1% concentration. On the other hand, for the acidic chemicals, the highest was only 38.1% recovery rate at 1% oxalic acid. Recovery efficiency increased as the concentration of chemicals and cleaning time increased. Organic or biofilm was considered as the main foulant as observed from the experimental results. In addition, the cleaning efficiency was better in basic than acidic.
引用
收藏
页码:5268 / 5274
页数:7
相关论文
共 50 条
  • [1] Effects of steam pretreatment on fouled membrane in chemical cleaning for flux recovery in drinking water treatment
    Eui-Jong Lee
    Seunghyeon Yun
    Hyungsoo Kim
    Environmental Science and Pollution Research, 2020, 27 : 35703 - 35711
  • [2] Effects of steam pretreatment on fouled membrane in chemical cleaning for flux recovery in drinking water treatment
    Lee, Eui-Jong
    Yun, Seunghyeon
    Kim, Hyungsoo
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2020, 27 (28) : 35703 - 35711
  • [3] Effect of chemical cleaning conditions on the flux recovery of MF membrane as pretreatment of seawater desalination
    Woo, Yun Chul
    Lee, Jeong Jun
    Oh, Jin Seok
    Kim, Han Seung
    DESALINATION AND WATER TREATMENT, 2013, 51 (31-33) : 6329 - 6337
  • [4] Cleaning strategies for flux recovery of an ultrafiltration membrane fouled by natural organic matter
    Lee, H
    Amy, G
    Cho, JW
    Yoon, YM
    Moon, SH
    Kim, IS
    WATER RESEARCH, 2001, 35 (14) : 3301 - 3308
  • [5] A new ultrasonic cleaning model for predicting the flux recovery of the UF membrane fouled with humic acid
    Luo, Huijia
    Wang, Zhan
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2022, 10 (02):
  • [6] RETRACTED: Cleaning Strategies for Flux Recovery of Ultrafiltraion Membrane Fouled by Reservoir Water (Retracted Article)
    Wang, Yi
    Yu, Li-jun
    Qi, Lu
    Li, Gui-Bai
    2011 INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENTAL SCIENCE-ICEES 2011, 2011, 11 : 3105 - 3109
  • [7] Chemical cleaning of reverse osmosis membrane fouled by wastewater
    Madaeni, S. S.
    Samieirad, S.
    DESALINATION, 2010, 257 (1-3) : 80 - 86
  • [8] CHEMICAL CLEANING OF MICROFILTRATION CERAMIC MEMBRANE FOULED BY NOM
    Bazin, Maisarah Mohamed
    Nakamura, Yuzo
    Ahmad, Norhayati
    JURNAL TEKNOLOGI, 2018, 80 (06): : 95 - 103
  • [9] Chemical cleaning of ultrafiltration membrane fouled by an activated sludge effluent
    Sy Thuy Nguyen
    Roddick, Felicity Anne
    DESALINATION AND WATER TREATMENT, 2011, 34 (1-3) : 94 - 99
  • [10] CHEMICAL CLEANING OF REVERSE OSMOSIS MEMBRANE FOULED BY APPLE JUICE
    Madaeni, S. S.
    Sasanihoma, A.
    Zereshki, S.
    JOURNAL OF FOOD PROCESS ENGINEERING, 2011, 34 (05) : 1535 - 1557