Intra- and Inter-Reader Variations in Lung Nodule Measurements: Influences of Nodule Size, Location, and Observers

被引:2
|
作者
Chen, Hong [1 ]
Huang, Haozhe [2 ,3 ]
Zhang, Jianye [1 ]
Wang, Xuexue [1 ]
Han, Mengyang [1 ]
Ding, Chanjun [1 ]
Wang, Jinhong [1 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Mental Hlth Ctr, Sch Med, Dept Med Imaging, Shanghai 200030, Peoples R China
[2] Fudan Univ, Shanghai Canc Ctr, Dept Intervent Radiol, 270 Dongan Rd, Shanghai 200032, Peoples R China
[3] Fudan Univ, Shanghai Med Coll, Dept Oncol, 130 Dongan Rd, Shanghai 200032, Peoples R China
关键词
chest; computed tomography; pulmonary nodules; measurement; imaging; three-dimensional; PULMONARY NODULES; ITERATIVE RECONSTRUCTION; SOLID TUMORS; CT; VOLUMETRY; VARIABILITY; CANCER; INTEROBSERVER;
D O I
10.3390/diagnostics12102319
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
(1) Background: Accurate measurement of lung-nodule size is necessary, but whether a three-dimensional volume measurement is better or more reliable than the one-dimensional method is still unclear. This study aimed to investigate the intra- and inter-reader variations according to nodule type, size, three-dimensional volume measurements, and one-dimensional linear measurements. (2) Methods: This retrospective study included computed tomography (CT) examinations of lung nodules and volume measurements performed from October to December 2016. Two radiologists independently performed all measurements. Intra-class correlation coefficients (ICC) and Bland-Altman plots were used for analysis. (3) Results: The overall variability in the calculated volume was larger than when using the semiautomatic volume measurement. Nodules <6 mm tended to have larger variability than nodules >= 6 mm in both one-dimensional and calculated volume measurements. The isolated type showed smaller variability in both intra- and inter-reader comparisons. The juxta-vascular type showed the largest variability in both one-dimensional and calculated volume measurements. The variability was decreased when using the 3D volume semiautomated software. (4) Conclusions: The present study suggests that 3D semiautomatic volume measurements showed lower variability than the calculated volume measurement. Nodule size and location influence measurement variability. The intra- and inter-reader variabilities in nodule volume measurement were considerable.
引用
收藏
页数:11
相关论文
共 44 条
  • [1] Influence of Nodule Morphology on Inter-Reader Variability of Volume and Diameter Measurements in CT Lung Cancer Screening
    Heuvelmans, Marjolein
    Han, Daiwei
    Vliegenthart, Rozemarijn
    De Jonge, Gonda
    Walter, Joan
    Van Ooijen, Peter
    De Koning, Harry
    Oudkerk, Matthijs
    [J]. JOURNAL OF THORACIC ONCOLOGY, 2017, 12 (01) : S345 - S346
  • [2] Inter-Reader Variability of Volumetric Subsolid Pulmonary Nodule Radiomic Features
    Azour, Lea
    Moore, William H.
    O'Donnell, Thomas
    Truong, Mylene T.
    Babb, James
    Niu, Bowen
    Wimmer, Andreas
    Kiumehr, Saman
    Ko, Jane P.
    [J]. ACADEMIC RADIOLOGY, 2022, 29 : S98 - S107
  • [3] QUANTITATIVE MORPHOMETRY: INTRA- AND INTER-READER REPRODUCIBILITY OF A NEW CLINICAL WORKFLOW TOOL
    Guglielmi, Giuseppe
    Nasuto, Michelangelo
    D'Errico, Francesco
    Placentino, Maria Grazia
    Di Chio, Francesca
    [J]. OSTEOPOROSIS INTERNATIONAL, 2013, 24 : S318 - S318
  • [4] INTRA- AND INTER-READER VARIABILITY OF TRANSVAGINAL ULTRASOUND BLADDER WALL THICKNESS MEASUREMENTS: RESULTS FROM THE SHRINK STUDY
    Tubaro, A.
    Khullar, V
    Oelke, M.
    Wijkstra, H.
    Tretter, R.
    Stow, B.
    Huang, M.
    Compion, G.
    Robinson, D.
    [J]. NEUROUROLOGY AND URODYNAMICS, 2013, 32 (06) : 711 - 712
  • [5] Assessing the intra- and inter-reader reliability of dynamic ultrasound images in power Doppler ultrasonography
    Koski, J. M.
    Saarakkala, S.
    Helle, M.
    Hakulinen, U.
    O Heikkinen, J.
    Hermunen, H.
    Balint, P.
    Bruyn, G. A.
    Filippucci, E.
    Grassi, W.
    Iagnocco, A.
    Luosujarvi, R.
    Manger, B.
    De Miguel, E.
    Naredo, E.
    Scheel, A. K.
    Schmidt, W. A.
    Soini, I.
    Szkudlarek, M.
    Terslev, L.
    Uson, J.
    Vuoristo, S.
    Ziswiler, H. R.
    [J]. ANNALS OF THE RHEUMATIC DISEASES, 2006, 65 (12) : 1658 - 1660
  • [6] Intra- and inter-reader reproducibility of blood flow measurements on the ascending aorta and pulmonary artery using cardiac magnetic resonance
    Giovanni Di Leo
    Ida Daniela D’Angelo
    Marco Alì
    Paola Maria Cannaò
    Giovanni Mauri
    Francesco Secchi
    Francesco Sardanelli
    [J]. La radiologia medica, 2017, 122 : 179 - 185
  • [7] Intra- and inter-reader reproducibility of blood flow measurements on the ascending aorta and pulmonary artery using cardiac magnetic resonance
    Di Leo, Giovanni
    D'Angelo, Ida Daniela
    Ali, Marco
    Cannao, Paola Maria
    Mauri, Giovanni
    Secchi, Francesco
    Sardanelli, Francesco
    [J]. RADIOLOGIA MEDICA, 2017, 122 (03): : 179 - 185
  • [8] Comparison of intra- and inter-reader agreement of abbreviated versus comprehensive MRCP for pancreatic cyst surveillance
    Huang, Chenchan
    Prabhu, Vinay
    Smereka, Paul
    Vij, Abhinav
    Anthopolos, Rebecca
    Hajdu, Cristina H.
    Dane, Bari
    [J]. ABDOMINAL RADIOLOGY, 2024, 49 (10) : 3517 - 3527
  • [9] Intra- and inter-reader reproducibility in quantitative coronary plaque analysis on coronary computed tomography angiography*
    Quintana, Raymundo A.
    Doeberitz, Philipp von Knebel
    Vatsa, Nishant
    Liu, Chang
    Ko, Yi-An
    De Cecco, Carlo N.
    van Assen, Marly
    Quyyumi, Arshed A.
    [J]. CURRENT PROBLEMS IN CARDIOLOGY, 2024, 49 (07)
  • [10] INTRA- AND INTER-READER RELIABILITY OF SEMI-AUTOMATED VERTEBRAL MORPHOMETRY MEASUREMENTS USING LATERAL SCOUTVIEWS FROM COMPUTED TOMOGRAPHY
    Kim, Y. M.
    Eisenberg, R.
    Bouxsein, M. L.
    [J]. OSTEOPOROSIS INTERNATIONAL, 2010, 21 : 216 - 216