Hard X-ray Imaging Polarimeter for PolariS

被引:1
|
作者
Hayashida, Kiyoshi [1 ]
Juyong, Kim [1 ]
Sadamoto, Masaaki [1 ]
Yoshinaga, Keigo [1 ]
Gunji, Shuichi [2 ]
Mihara, Tatehiro [3 ]
Kishimoto, Yuji [4 ]
Kubo, Hidetoshi [5 ]
Mizuno, Tsunefumi [6 ]
Takahashi, Hiromitsu [6 ]
Dotani, Tadayasu [7 ]
Yonetoku, Daisuke [8 ]
Nakamori, Takeshi [2 ]
Yoneyema, Tomokage [1 ]
Ikeyama, Yuki [1 ]
Kamitsukasa, Fumiyoshi [1 ]
机构
[1] Osaka Univ, Dept Earth & Space Sci, Machikaneyama 1-1, Toyonaka, Osaka 5600043, Japan
[2] Yamagata Univ, Dept Phys, Yamagata 990, Japan
[3] RIKEN, Wako, Saitama, Japan
[4] KEK, Tsukuba, Ibaraki, Japan
[5] Kyoto Univ, Dept Phys, Kyoto, Japan
[6] Hiroshima Univ, Higashihiroshima, Japan
[7] ISAS JAXA, Sagamihar, Japan
[8] Kanazawa Univ, Kanazawa, Ishikawa, Japan
关键词
X-ray polarimetry; Scintillators; Hard X-ray; PolariS; PERFORMANCE;
D O I
10.1117/12.2232472
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Hard X-ray imaging polarimeters are developed for the X-ray gamma-ray polaeimtery satellite PolariS. The imaging polarimter is scattering type, in which anisotropy in the direction of Compton scattering is employed to measure the hard X-ray (10-80 keV) polarization, and is installed on the focal planes of hard X-ray telescopes. We have updated the design of the model so as to cover larger solid angles of scattering direction. We also examine the event selection algorithm to optimize the detection efficiency of recoiled electrons in plastic scintillators. We succeed in improving the efficiency by factor of about 3-4 from the previous algorithm and criteria for 18-30 keV incidence. For 23 keV X-ray incidence, the recoiled electron energy is about 1 keV. We measured the efficiency to detect recoiled electrons in this case, and found about half of the theoretical limit. The improvement in this efficiency directly leads to that in the detection efficiency. In other words, however, there is still a room for improvement. We examine various process in the detector, and estimate the major loss is primarily that of scintillation light in a plastic scintillator pillar with a very small cross section (2.68mm squared) and a long length (40mm). Nevertheless, the current model provides the MDP of 6% for 10mCrab sources, which are the targets of PolariS.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] An X-ray polarimeter for hard X-ray optics
    Muleri, Fabio
    Bellazzini, Ronaldo
    Costa, Enrico
    Soffitta, Paolo
    Lazzarotto, Francesco
    Feroci, Marco
    Pacciani, Luigi
    Rubini, Alda
    Morelli, Ennio
    Baldini, Luca
    Bitti, Francesco
    Brez, Alessandro
    Cavalca, Francesco
    Latronic, Luca
    Massai, Marco Maria
    Omodei, Nicola
    Pinchera, Michele
    Sgro, Carmelo
    Spandre, Gloria
    Matt, Giorgio
    Perola, Giuseppe Cesare
    Citterio, Oberto
    Pareschi, Giovanni
    Cotroneo, Vincenzo
    Spiga, Daniele
    Canestrari, Rodolfo
    Space Telescopes and Instrumentation II: Ultraviolet to Gamma Ray, Pts 1 and 2, 2006, 6266 : X2662 - X2662
  • [2] RHESSI as a Hard X-Ray Polarimeter
    Mark L. McConnell
    James M. Ryan
    David M. Smith
    Robert P. Lin
    A. Gordon Emslie
    Solar Physics, 2002, 210 : 125 - 142
  • [3] RHESSI as a hard X-ray polarimeter
    McConnell, ML
    Ryan, JM
    Smith, DM
    Lin, RP
    Emslie, AG
    SOLAR PHYSICS, 2002, 210 (1-2) : 125 - 142
  • [4] A hard x-ray imaging polarimeter for balloon-borne astronomy
    Austin, RA
    Minamitani, T
    Ramsey, BD
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 131 - 135
  • [5] Development of hard X-ray polarimeter for γ-ray bursts
    Gunji, S
    Suzuki, T
    Sato, F
    Sakurai, H
    Tokanai, F
    Saito, Y
    Kubota, A
    NEXT GENERATION IN SCIENTIFIC BALLOONING, 2004, 33 (10): : 1771 - 1776
  • [6] The Hard X-Ray Polarimeter X-Calibur
    Kislat, Fabian
    Beilicke, Matthias
    Baring, Matthew G.
    Barthelmy, Scott D.
    Bodaghee, Arash
    Cowsik, Ramanath
    De Geronimo, Gianluigi
    Dowkontt, Paul
    Endsley, Ryan
    Guo, Qingzhen
    Haba, Yoshito
    Krawczynski, Henric
    Mitchell, John
    Miyazawa, Takuya
    Okajima, Takashi
    Saji, Shigetaka
    Schnittman, Jeremy D.
    Zeiger, Benjamin R.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [7] The hard X-ray polarimeter X-Calibur
    Beilicke, M.
    Baring, M. G.
    Barthelmy, S.
    Binns, W. R.
    Buckley, J.
    Cowsik, R.
    Dowkontt, P.
    Guo, Q.
    Haba, Y.
    Israel, M. H.
    Kunieda, H.
    Lee, K.
    Martin, J.
    Matsumoto, H.
    Miyazawa, T.
    Okajima, T.
    Schnittman, J.
    Tamura, K.
    Tueller, J.
    Krawczynski, H.
    HIGH ENERGY GAMMA-RAY ASTRONOMY, 2012, 1505 : 805 - 808
  • [8] A NEW DESIGN OF HARD X-RAY POLARIMETER
    GUNJI, S
    SAKURAI, H
    NOMA, M
    TAKASE, E
    SAITO, T
    MISAWA, H
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) : 1309 - 1312
  • [9] Development of a hard X-ray polarimeter for astrophysics
    McConnell, ML
    Macri, JR
    McClish, M
    Ryan, J
    Forrest, DJ
    Vestrand, WT
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (04) : 890 - 896
  • [10] Concept of a CubeSat-based hard X-ray imaging polarimeter: cipher
    Odaka, Hirokazu
    Kasuga, Tomoaki
    Hatauchi, Kosuke
    Tamba, Tsubasa
    Takashima, Satoshi
    Suzuki, Hiromasa
    Watanabe, Taihei
    Nammoku, Sorato
    Tanimoto, Atsushi
    Aizawa, Yuki
    Bamba, Aya
    SPACE TELESCOPES AND INSTRUMENTATION 2020: ULTRAVIOLET TO GAMMA RAY, 2021, 11444