Development of a quantitative method for determination of steroids in human plasma by gas chromatography-negative chemical ionization-tandem mass spectrometry

被引:9
|
作者
Luque-Cordoba, D. [1 ,2 ,3 ,4 ]
Lopez-Bascon, M. A. [1 ,2 ,3 ,4 ]
Priego-Capote, F. [1 ,2 ,3 ,4 ]
机构
[1] Univ Cordoba, Dept Analyt Chem, Annex Marie Curie Bldg,Campus Rabanales, Cordoba, Spain
[2] Univ Cordoba, Nanochem Univ Inst IUNAN, Campus Rabanales, Cordoba, Spain
[3] Univ Cordoba, Reina Sofia Univ Hosp, Maimonides Inst Biomed Res IMIBIC, Cordoba, Spain
[4] Inst Salud Carlos III, CIBER Fragilidad & Envejecimiento Saludable CIBER, Madrid, Spain
关键词
Sex steroids; GC-MS/MS; Plasma; Negative chemical ionization; Sample preparation; SOLID-PHASE EXTRACTION; SERUM SEX STEROIDS; LC-MS/MS METHOD; ENDOGENOUS STEROIDS; PROGESTERONE; ESTROGENS; ESTRADIOL; TESTOSTERONE; ANDROGEN; RISK;
D O I
10.1016/j.talanta.2020.121415
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Sex steroids are involved in biological functions that encompass from the complete sexual development of individuals up to the deregulation of metabolic pathways leading to some pathologies. Steroids are present in blood at low concentration levels from pg mL 1 to ng mL(-1). For this reason, a high sensitive and selective method based on gas chromatography-negative chemical ionization-tandem mass spectrometry (GC-NCI-MS/MS) is here proposed to quantify either androgens (androstenedione, dehydroepiandrosterone, dihydrotestosterone and testosterone), estrogens (estrone and estradiol) and a progestogen (progesterone) in human plasma. The sample preparation steps, protein precipitation and solid phase extraction, were optimized to ensure the sample matrix removal and to extract steroids with high efficiency. The NCI-MS/MS detection approach was compared with that based on electron impact to evaluate the incidence of the ionization source in the determination of steroids. The quantification limits for determination of these analytes were in a range from 10 pg mL(-1) to 5 ng mL(-1), with a high sensitivity for estrogens, typically found at low concentrations. The proposed method was tested for the determination of steroids in male blood samples, in which 6 out of 7 steroids were detected and quantified to report concentration values in agreement with those described in the literature.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Quantitative determination of clonazepam in plasma by gas chromatography-negative ion chemical ionization mass spectrometry
    Song, DM
    Zhang, S
    Kohlhof, K
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 686 (02): : 199 - 204
  • [2] Quantitative analysis of morphine in human plasma by gas chromatography-negative ion chemical ionization mass spectrometry
    Leis, HJ
    Fauler, G
    Raspotnig, G
    Windischhofer, W
    JOURNAL OF CHROMATOGRAPHY B, 2000, 744 (01): : 113 - 119
  • [3] Determination of Fipronil and Four Metabolites in Animal-Derived Foods by Gas Chromatography-Negative Chemical Ionization-Tandem Mass Spectrometry
    Han C.
    Hu B.
    Jin N.
    Liu B.
    Shen Y.
    Jin J.
    Chen S.
    Chen, Shubing (shubingchen@126.com), 1600, Chinese Chamber of Commerce (41): : 327 - 331
  • [4] Quantitation of phenanthrene dihydrodiols in the urine of smokers and nonsmokers by gas chromatography-negative ion chemical ionization-tandem mass spectrometry
    Luo, Kai
    Hochalter, J. Bradley
    Carmella, Steven G.
    Hecht, Stephen S.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2020, 1141 (1141):
  • [5] Enantioselective gas chromatography-negative ion chemical ionization mass spectrometry for methylphenidate in human plasma
    Lin, SN
    Andrenyak, DM
    Moody, DE
    Foltz, RL
    JOURNAL OF ANALYTICAL TOXICOLOGY, 1999, 23 (06) : 524 - 530
  • [6] Quantitative determination of rhein in human plasma by liquid chromatography-negative electrospray ionization tandem mass/mass spectrometry and the application in a pharmacokinetic study
    Jiang, Jun-yi
    Yang, Ming-wei
    Qian, Wei
    Lin, Hui
    Geng, Yan
    Zhou, Zhi-qun
    Xiao, Da-wei
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 57 : 19 - 25
  • [7] DETERMINATION OF FLUMAZENIL IN PLASMA BY GAS CHROMATOGRAPHY-NEGATIVE ION CHEMICAL-IONIZATION MASS-SPECTROMETRY
    SONG, DM
    KHAYKIS, V
    KOHLHOF, K
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 663 (02): : 263 - 273
  • [8] Determination of deltamethrin in rat plasma and brain using gas chromatography-negative chemical ionization mass spectrometry
    Gullick, Darren
    Popovici, Andrew
    Young, Holly C.
    Bruckner, James V.
    Cummings, Brian S.
    Li, Pei
    Bartlett, Michael G.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 960 : 158 - 165
  • [9] Determination of cyflufenamid residue in carrots by gas chromatography-negative chemical ionization mass spectrometry
    Yang Wenquan
    Shen Weijian
    Zhao Zengyun
    Xu Jinzhong
    Shen Chongyu
    Wu Bin
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2008, 26 (04) : 526 - 528
  • [10] Determination of Difenoconazole Residue in Foods by Gas Chromatography-Negative Chemical Ionization Mass Spectrometry
    Shen Weijian
    Yang Wenquan
    Shen Chongyu
    Zhao Zengyun
    Xu Jinzhong
    Ding Tao
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2007, 25 (03) : 418 - 421