Upgrade of the Muon Sorter in the Cathode Strip Chamber Level 1 Trigger System at CMS

被引:0
|
作者
Acosta, D. [2 ]
Ecklund, K. [1 ]
Furic, I. [2 ]
Liu, J. [1 ]
Madorsky, A. [2 ]
Matveev, M. [1 ]
Padley, P. [1 ]
机构
[1] Rice Univ, Houston, TX 77005 USA
[2] Univ Florida, Gainesville, FL 32611 USA
来源
关键词
Trigger algorithms; Digital electronic circuits;
D O I
10.1088/1748-0221/8/11/C11016
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The top level of the Level 1 Trigger System in the Cathode Strip Chamber (CSC) detector at CMS consists of the Track Finder (TF) crate with 12 Sector Processors (SP) and one Muon Sorter (MS) board. The MS provides sorting of up to 36 trigger objects from the SP boards, selects the four best (by a definable criterion) ones, and transmits then to the Global Trigger crate of CMS. With the anticipated LHC luminosity increase above 10(34) cm(-2)s(-1) at an energy of 6.5-7 TeV/beam the CSC TF needs to be upgraded. The new CSCTF will be robust to higher occupancies, provide improved transverse momentum assignment and increased precision of the muon output variables. A transition from the current 9U VME electronic standard to the more flexible uTCA and utilization of the Xilinx Virtex-6 and Virtex-7 FPGAs, with multiple embedded gigabit links, will allow us to build a higher performance TF such that the MS functions can be performed by one of the SP modules. We present here the results of our efforts in the past year to upgrade the CSC Muon Sorter, including the short term modifications of the existing VME board, long-term transition to the uTCA as well as firmware development for both of these projects.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Upgrade of the cathode strip chamber level 1 trigger optical links at CMS
    Ecklund, K.
    Liu, J.
    Madorsky, A.
    Matveev, M.
    Padley, P.
    [J]. JOURNAL OF INSTRUMENTATION, 2012, 7
  • [2] Primitives for the CMS Cathode Strip muon trigger
    Hauser, J
    [J]. PROCEEDINGS OF THE FIFTH WORKSHOP ON ELECTRONICS FOR LHC EXPERIMENTS, 1999, : 304 - 308
  • [3] Development and test of a prototype regional track-finder for the Level-1 trigger of the cathode strip chamber muon system of CMS
    Acosta, D
    Adams, N
    Atamanchouk, A
    Cousins, RD
    Ferguson, MI
    Golovtsov, V
    Hauser, J
    Madorsky, A
    Matveev, M
    Mumford, J
    Nussbaum, T
    Padley, P
    Razmyslovich, B
    Sedov, V
    Smith, W
    Tannenbaum, B
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 496 (01): : 64 - 82
  • [4] Upgrade of the CMS muon trigger system in the barrel region
    Rabady, Dinyar
    Ero, Janos
    Flouris, Giannis
    Fulcher, Jonathan
    Loukas, Nikitas
    Paradas, Evangelos
    Reis, Thomas
    Sakulin, Hannes
    Wulz, Claudia-Elisabeth
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 845 : 616 - 620
  • [5] Cathode strip chamber performance of the CMS ME1/1 Muon Station
    Erchov, Y
    Golutvin, I
    Gorbunov, N
    Gramenitsky, I
    Karjavin, V
    Khabarov, S
    Khabarov, V
    Kiryushin, Y
    Lusiakov, V
    Mechtcheriakov, G
    Melnichenko, I
    Moissenz, P
    Movchan, S
    Palichik, V
    Perelygin, V
    Smolin, D
    Zarubin, A
    Zubarev, E
    Dvornikov, O
    Shumeiko, N
    Solin, A
    Tchekhovski, V
    [J]. ADVANCED TECHNOLOGY AND PARTICLE PHYSICS, PROCEEDINGS, 2002, 1 : 347 - 351
  • [6] Cathode Strip Chamber for CMS ME1/1 Endcap Muon Station
    Erchov, Yu. V.
    Golunov, A. O.
    Golutvin, I. A.
    Gorbunov, N. V.
    Kamenev, A. Yu.
    Karjavin, V. Yu.
    Khabarov, S. V.
    Khabarov, V. S.
    Kiryushin, Yu. T.
    Kurenkov, A. M.
    Kurenkov, A. A.
    Ladygin, V. P.
    Lysiakov, V. N.
    Mescheriakov, G. V.
    Moissenz, P. V.
    Moissenz, K. P.
    Movchan, S. A.
    Perelygin, V. V.
    Rashevsky, V. P.
    Samsonov, V. A.
    Slepnev, I. V.
    Smolin, D. A.
    Vassiliev, S. E.
    Vasiliev, T. A.
    Zarubin, A. V.
    Zubarev, E. V.
    [J]. PHYSICS OF PARTICLES AND NUCLEI LETTERS, 2006, 3 (03) : 183 - 187
  • [7] Upgrade of the CMS Global Muon Trigger
    Lingemann, Joschka
    Rabady, Dinyar
    Sakulin, Hannes
    Jeitler, Manfred
    Stahl, Achim
    [J]. 2014 19TH IEEE-NPSS REAL TIME CONFERENCE (RT), 2014,
  • [8] The CMS Barrel Muon trigger upgrade
    Triossi, A.
    Bellato, M.
    Cela Ruiz, J. M.
    Ero, J.
    Fernandez Bedoya, C.
    Flouris, G.
    Foudas, C.
    Guiducci, L.
    Loukas, N.
    Navarro Tobar, A.
    Mallios, S.
    Masetti, G.
    Montecassiano, F.
    Paradas, E.
    Redondo Fernandez, I.
    Ferrero, D. Redondo
    Sastre, J.
    Sphicas, P.
    Ventura, S.
    Wulz, C.
    [J]. JOURNAL OF INSTRUMENTATION, 2017, 12
  • [9] Upgrade of the CMS Global Muon Trigger
    Jeitler, Manfred
    Lingemann, Joschka
    Rabady, Dinyar
    Sakulin, Hannes
    Stahl, Achim
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (03) : 1104 - 1109
  • [10] RPC system in the CMS Level-1 Muon Trigger
    Samalan, A.
    Tytgat, M.
    Zaganidis, N.
    Alves, G. A.
    Marujo, F.
    Da Silva De Araujo, F. Torres
    Da Costa, E. M.
    De Jesus Damiao, D.
    Nogima, H.
    Santoro, A.
    Fonseca De Souza, S.
    Aleksandrov, A.
    Hadjiiska, R.
    Iaydjiev, P.
    Rodozov, M.
    Shopova, M.
    Sultanov, G.
    Bonchev, M.
    Dimitrov, A.
    Litov, L.
    Pavlov, B.
    Petkov, P.
    Petrov, A.
    Qian, S. J.
    Cao, P.
    Kou, H.
    Liu, Z.
    Song, J.
    Zhao, J.
    Bernal, C.
    Cabrera, A.
    Fraga, J.
    Sarkar, A.
    Elsayed, S.
    Assran, Y.
    El Sawy, M.
    Mahmoud, M. A.
    Mohammed, Y.
    Combaret, C.
    Gouzevitch, M.
    Grenier, G.
    Laktineh, I
    Mirabito, L.
    Shchablo, K.
    Bagaturia, I
    Lomidze, D.
    Lomidze, I
    Bhatnagar, V
    Gupta, R.
    Kumari, P.
    [J]. JOURNAL OF INSTRUMENTATION, 2020, 15 (10):