Fast 3D-EM reconstruction using Planograms for stationary planar positron emission mammography camera

被引:9
|
作者
Motta, A
Del Guerra, A
Belcari, N
Moehrs, S
Panetta, D
Righi, S
Valentini, D
机构
[1] Univ Pisa, Dept Phys, I-56127 Pisa, Italy
[2] Ist Nazl Fis Nucl, I-56127 Pisa, Italy
[3] Univ Pisa, Scuola Specializzaz Fis Sanit, Pisa, Italy
[4] Azienda Osped SS Antonio & Biagio & C Arrigo di A, I-15100 Alessandria, Italy
关键词
Positron emission mammography; YAP-PEM Planar camera; Planogram; image reconstruction; Expectation maximization; Maximum likelihood;
D O I
10.1016/j.compmedimag.2005.07.002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
At the University of Pisa we are building a PEM prototype, theYAP-PEM camera, consisting of two opposite 6X6X3 cm(3) detector heads of 30 X 30 YAP:Ce finger crystals, 2 X 2 X 30 mm(3) each. The camera will be equipped with breast compressors. The acquisition will be stationary. Compared with a whole body PET scanner, a planar Positron Emission Mammography (PEM) camera allows a better, easier and more flexible positioning around the breast in the vicinity of the tumor: this increases the sensitivity and solid angle coverage, and reduces cost. To avoid software rejection of data during the reconstruction, resulting in a reduced sensitivity, we adopted a 3D-EM reconstruction which uses all of the collected Lines OfResponse (LORs). This skips the PSF distortion given by data rebinning procedures and/or Fourier methods. The traditional 3D-EM reconstruction requires several times the computation of the LOR-voxel correlation matrix, or probability matrix {p(ij)}; therefore is highly time-consuming. We use the sparse and symmetry properties of the matrix {p(ij)} to perform fast 3D-EM reconstruction. Geometrically, a 3D grid Of Cubic voxels (FOV) is crossed by several divergent 3D line sets (LORs). The symmetries occur when tracing different LORs produces the same p(ij) Value. Parallel LORs of different sets cross the FOV in the same way, and the repetition of p(ij) values depends on the ratio between the tube and voxel sizes. By optimizing this ratio, the occurrence of symmetries is increased. We identify a nucleus of symmetry of LORs: for each set of symmetrical LOR, we choose just one LOR to be put in the nucleus, while the others lie Outside. All of the possible p(ij) values are obtainable by tracking only the LORs of this nucleus. The coordinates of the voxels of all of the other LORs are given by means of simple translation rules. Before making the reconstruction, we trace the LORs of the nucleus to find the intersecting voxels, whose p(ij) values are computed and stored with their voxel coordinates on a hard disk. Only the non-zero pij are considered and their computation is performed just once. During the reconstruction, the stored values are loaded and are available in the random access memory for all of the operations of normalization, backprojection and projection: these are now performed rapidly, because the application of the translation rules is much faster than the probability computations. We tested the algorithm on Monte Carlo data fully simulating the typical YAP-PEM clinical condition. The adopted algorithm gives an excellent positioning capability for hot spots in the camera FOV. TO use all of the possible skew LORs in the FOV avoids the software rejection of collected data. Reconstructed images indicate that a 5 mm diameter tumor of 37 kBq/cm(3) in an, to Back round ratio (T/B), with a 10 min acquisition, for a head distance of 5 cm, can be detected by the YAP-PEM with a SNR of 8.7 +/- 1.0. The obtained SNR values depend linearly on the tumor volume. The algorithm allows one to discriminate between two hot sources of 5.0 mm diameter if they do not lie on the same axis. The YAP-PEM is now in the assembly stage. (C) 2005 Elsevier Ltd. All rights reserved.
引用
下载
收藏
页码:587 / 596
页数:10
相关论文
共 50 条
  • [1] 3-D ITERATIVE RECONSTRUCTION METHOD FOR STATIONARY PLANAR POSITRON CAMERA.
    Chun Bin Lim
    Cheng, Andrew
    Boyd, Douglas P.
    Hattner, Robert S.
    1600, (NS 25):
  • [3] POSITRON EMISSION LONGITUDINAL TOMOGRAPHY WITH STATIONARY PLANAR MWPC POSITRON CAMERA
    LIM, CB
    PEREZMENDEZ, V
    CHENG, A
    HATTNER, RS
    KAUFMAN, L
    JOURNAL OF NUCLEAR MEDICINE, 1978, 19 (06) : 707 - 707
  • [4] Fast fully 3-D image reconstruction in PET using planograms
    Brasse, D
    Kinahan, PE
    Clackdoyle, R
    Defrise, M
    Comtat, C
    Townsend, DW
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (04) : 413 - 425
  • [5] 3-D ITERATIVE RECONSTRUCTION METHOD FOR STATIONARY PLANAR POSITRON CAMERAS
    LIM, CB
    CHENG, A
    BOYD, DP
    HATTNER, RS
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1978, 25 (01) : 196 - 201
  • [6] Optimization of 2D image reconstruction for positron emission mammography using IDL
    Oliveira, N.
    Matela, N.
    Bugalho, P.
    Ferreira, N.
    Almeida, P.
    COMPUTERS IN BIOLOGY AND MEDICINE, 2009, 39 (02) : 119 - 129
  • [7] Grid computing in 3D-EM image processing using Xmipp
    Scheres, SHW
    Merino, AJ
    Sorzano, COS
    Carazo, JM
    18TH IEEE SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS, PROCEEDINGS, 2005, : 561 - 563
  • [8] 3D Object Reconstruction using Stationary RGB Camera
    Junior, Jose G. dos S.
    Lima, Gustavo C. R.
    Pinto, Adam H. M.
    Lima, Joao Paulo S. do M.
    Teichrieb, Veronica
    Quintino, Jonysberg P.
    da Silva, Fabio Q. B.
    Santos, Andre L. M.
    Pinho, Helder
    PROCEEDINGS OF THE 17TH INTERNATIONAL JOINT CONFERENCE ON COMPUTER VISION, IMAGING AND COMPUTER GRAPHICS THEORY AND APPLICATIONS (VISAPP), VOL 5, 2022, : 793 - 800
  • [9] Modeling of a millimeter wave planar Schottky diode using both improved equivalent circuit model and 3D-EM model
    Li, Li
    Zhang, Yong
    Zhao, Wei
    Liu, Shuang
    Xu, Ruimin
    OPTIK, 2014, 125 (13): : 3324 - 3327
  • [10] An Analysis Scheme for 3D Visualization of Positron Emitting Radioisotopes Using Positron Emission Mammography System
    Islam, Md. Rafiqul
    Beni, Mehrdad Shahmohammadi
    Ito, Shigeki
    Gotoh, Shinichi
    Yamaya, Taiga
    Watabe, Hiroshi
    APPLIED SCIENCES-BASEL, 2022, 12 (02):