Evaluation of the fit of metal ceramic restorations fabricated with a pre-sintered soft alloy

被引:31
|
作者
Park, Jong-Kyoung [1 ]
Kim, Hae-Young [2 ]
Kim, Woong-Chul [3 ]
Kim, Ji-Hwan [3 ]
机构
[1] Korea Univ, Coll Hlth Sci, Dept Dent Lab Sci & Engn, Seoul, South Korea
[2] Korea Univ, Grad Sch, Dept Publ Hlth Sci, Seoul, South Korea
[3] Korea Univ, Coll Hlth Sci, Dept Dent Lab Sci & Engn, Seoul, South Korea
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2016年 / 116卷 / 06期
基金
新加坡国家研究基金会;
关键词
FIXED DENTAL PROSTHESES; INTERNAL ADAPTATION; FILM THICKNESS; MARGINAL FIT; IN-VIVO; CROWNS; CEMENT; STRENGTH; GAPS;
D O I
10.1016/j.prosdent.2016.03.024
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Fit is an important factor influencing the success or failure of restorations. Recently, there has been increasing use of a newly developed pre-sintered soft alloy for use in computer-aided design and computer-aided manufacturing (CAD-CAM) of cobalt-chromium alloys for the fabrication of metal ceramic restorations. However, almost no studies are available on the fit of restorations fabricated in this way. Purpose. The purpose of this in vitro study was to evaluate the fit of metal coping fabricated from a newly developed CAD-CAM soft alloy in order to investigate its clinical applicability. Material and methods. Metal coping was categorized as casting alloy (CA), fully sintered hard alloy (FHA), or pre-sintered soft alloy (PSA) depending on the material, and 10 specimens of each category were fabricated. Seven measurement locations were selected in both the mesiodistal and labiolingual directions. For measurement of the marginal and internal discrepancies, silicone molds produced using a silicone replica technique were divided into mesiodistal and labiolingual cross sections, and the width was measured. The Kruskal-Wallis and Mann-Whitney U test were performed (corrected alpha error level=.05/3). Results. The mean values of the total discrepancy were smallest in the CA group (52.53 +/- 33.40 gm) and largest in the FHA group (87.84 +/- 39.43 mu m). The CA group and the PSA group were not significantly different from each other (P>.05) but were statistically significantly different from the FHA group (P<.001). In particular, the absolute marginal discrepancy did not differ significantly between the CA (33.68 +/- 8.44 mu m) and PSA groups (37.01 +/- 8.04 mu m) (P>.05). Conclusions. The fit of the PSA restorations determined by this study was similar to that of conventional cast restorations. Both FHA and PSA restorations demonstrated clinically acceptable values (<120 mu m).
引用
收藏
页码:909 / 915
页数:7
相关论文
共 50 条
  • [1] Precision of the milled full-arch framework fabricated using pre-sintered soft alloy: A pilot study
    Woo, Hyun-Wook
    Cho, Sung-Am
    Lee, Cheong-Hee
    Lee, Kyu-Bok
    Cho, Jin-Hyun
    Lee, Du-Hyeong
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2018, 10 (02): : 128 - 131
  • [2] Micro machining of pre-sintered ceramic green body
    Li, Jian-Zhong
    Wu, Tao
    Yu, Zu-Yuan
    Zhang, Long
    Chen, Guo-Qing
    Guo, Dong-Ming
    [J]. JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2012, 212 (03) : 571 - 579
  • [3] Comparison of the Marginal Fit of Pressable Ceramic to Metal Ceramic Restorations
    Holden, Jason E.
    Goldstein, Gary R.
    Hittelman, Eugene L.
    Clark, Elizabeth A.
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2009, 18 (08): : 645 - 648
  • [4] Evaluation of Polycrystalline Diamond Tools in Milling of Pre-Sintered and Fully-Sintered Zirconia Ceramics
    Xu, Jinyang
    Ji, Min
    Li, Linfeng
    Chen, Ming
    [J]. JOURNAL OF SUPERHARD MATERIALS, 2022, 44 (01) : 62 - 69
  • [5] Evaluation of Polycrystalline Diamond Tools in Milling of Pre-Sintered and Fully-Sintered Zirconia Ceramics
    Min Jinyang Xu
    Linfeng Ji
    Ming Li
    [J]. Journal of Superhard Materials, 2022, 44 : 62 - 69
  • [6] Effect of CAD-CAM Framework Design Fabricated from Sintered Cobalt-Chromium Alloy on Fracture Resistance of Metal-Ceramic Restorations
    Afshar, Kourosh
    Falahchai, Mehran
    Ansarilari, Homeira
    Tajziehchi, Gelareh
    [J]. INTERNATIONAL JOURNAL OF DENTISTRY, 2023, 2023
  • [7] EVALUATION OF CERAMIC MARGINS FOR METAL-CERAMIC RESTORATIONS
    COONEY, JP
    RICHTER, WA
    MACENTEE, MI
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1985, 54 (01): : 1 - 5
  • [8] MARGINAL FIT OF CAPTEK AND CONVENTIONAL METAL-CERAMIC RESTORATIONS
    JUNTAVEE, N
    NATHANSON, D
    GIORDANO, R
    [J]. JOURNAL OF DENTAL RESEARCH, 1995, 74 : 421 - 421
  • [9] Porosity variation in the compressive deformation of pre-sintered Al-Si-Fe based alloy
    Shim, GS
    Kim, MS
    Kim, WY
    Yamagata, H
    [J]. ECO-MATERIALS PROCESSING & DESIGN, 2003, 439 : 40 - 45
  • [10] Marginal fit of leucite-glass pressable ceramic restorations and ceramicpressed-to-metal restorations
    Goldin, EB
    Boyd, NW
    Goldstein, GR
    Hittelman, EL
    Thompson, VP
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2005, 93 (02): : 143 - 147