A switch-mode boost DC-DC converter for IR-drop compensation of charging cable

被引:3
|
作者
Moon, Young-Jin [1 ]
Yoo, Changsik [1 ]
机构
[1] Hanyang Univ, Dept Elect Engn, Integrated Circuits Lab, Seoul 133791, South Korea
关键词
DC-DC converter; charging cable; IR-drop; switch-mode; power efficiency; BCDMOS; FREQUENCY; EFFICIENCY;
D O I
10.1002/cta.2017
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A switch-mode boost DC-DC converter has been developed to compensate for the IR-drop because of the finite resistance of a charging cable. The boost ratio of the DC-DC converter is adaptively controlled by an IR-drop sensing circuit to provide the required voltage level to a battery charger regardless of the cable resistance. Implemented in a 0.18 mu m BCDMOS process, the IR-drop compensating switch-mode boost DC-DC converter occupies 6.2mm(2) active area and shows the 93.2% peak efficiency. The proposed IR-drop compensating boost converter can be applied to compensate for the IR-drop of any type of charging cables. Copyright (c) 2014 John Wiley & Sons, Ltd.
引用
收藏
页码:1391 / 1398
页数:8
相关论文
共 50 条
  • [1] Design of Type-III Controller for DC-DC Switch-Mode Boost Converter
    Ghosh, Arnab
    Banerjee, Subrata
    2014 6th IEEE Power India International Conference (PIICON), 2014,
  • [2] Intelligent Identification of Switch-Mode DC-DC Converters
    Mousavi, Alireza
    Khanmirza, Esmaeel
    Nazarahari, Milad
    2015 3RD RSI INTERNATIONAL CONFERENCE ON ROBOTICS AND MECHATRONICS (ICROM), 2015, : 13 - 18
  • [3] Modeling of switch-mode DC-DC cascade converters
    Morales-Saldaña, JA
    Gutierrez, EEC
    Leyva-Ranos, J
    IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 2002, 38 (01) : 295 - 299
  • [4] On the optimal control of switch-mode DC-DC converters
    Geyer, T
    Papafotiou, G
    Morari, M
    HYBRID SYSTEMS: COMPUTATION AND CONTROL, PROCEEDINGS, 2004, 2993 : 342 - 356
  • [5] Uncertainty models for switch-mode DC-DC converters
    Leyva-Ramos, J
    Morales-Saldaña, JA
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-FUNDAMENTAL THEORY AND APPLICATIONS, 2000, 47 (02): : 200 - 203
  • [6] An efficient switch-mode power supply using an AC-DC interleaved boost converter and a DC-DC full-bridge topology
    Tofoli, Fernando Lessa
    Gallo, Carlos Alberto
    INTERNATIONAL JOURNAL OF ELECTRONICS, 2011, 98 (04) : 425 - 448
  • [7] Hybrid modelling and optimal control of switch-mode dc-dc converters
    Papafiotiou, G
    Geyer, T
    Morari, M
    PROCEEDINGS OF THE 2004 IEEE WORKSHOP ON COMPUTERS IN POWER ELECTRONICS, 2004, : 148 - 155
  • [8] Small-signal transmittances of the non-ideal flyback switch-mode DC-DC converter
    Batczek, Maciej
    Janke, Wlodzimierz
    Krasniewski, Jaroslaw
    ARCHIVES OF ELECTRICAL ENGINEERING, 2024, 73 (01) : 1 - 15
  • [9] Observer-based controller for switch-mode DC-DC converters
    Gonzalez-Fonseca, N.
    de Leon-Morales, J.
    Leyva-Ramos, J.
    2005 44th IEEE Conference on Decision and Control & European Control Conference, Vols 1-8, 2005, : 4773 - 4778
  • [10] Behavior modeling of magnetizing currents in switch-mode DC-DC converters
    Lee, YS
    Wong, KC
    Ng, CK
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2000, 47 (01) : 36 - 44