Calculation of vacuum conditions inside a FED using a Monte-Carlo method

被引:0
|
作者
Zoulkarneev, AR [1 ]
Park, NS [1 ]
Hong, JP [1 ]
Kim, JM [1 ]
机构
[1] SAMSUNG ADV INST TECHNOL,MAT & DEVICES RES CTR,SUWON 440600,SOUTH KOREA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Vacuum properties of a field emission display (FED) device are calculated using a Monte-Carlo method. The calculation is based on molecular flow conductance inside the FED panel with the exhausting pipe. This simulation result exhibits extremely low value of the conductance, resulting in pressure increase inside the panel by several orders of magnitude, even though large separation distance of the exhausting pipe is allowed like few centimeters.