Real-time continuous glucose monitoring in type 1 diabetes: a systematic review and individual patient data meta-analysis

被引:42
|
作者
Benkhadra, Khalid [1 ,2 ]
Alahdab, Fares [1 ,2 ]
Tamhane, Shrikant [3 ]
Wang, Zhen [1 ]
Prokop, Larry J. [4 ]
Hirsch, Irl B. [5 ]
Raccah, Denis [6 ]
Riveline, Jean-Pierre [7 ]
Kordonouri, Olga [8 ]
Murad, Mohammad Hassan [1 ,2 ]
机构
[1] Mayo Clin, Robert D & Patricia E Kern Ctr Sci Hlth Care Deli, Rochester, MN USA
[2] Mayo Clin, Div Prevent Med, 200 First St SW, Rochester, MN 55905 USA
[3] Mayo Clin, Div Endocrinol Diabet & Nutr, Rochester, MN USA
[4] Mayo Clin, Lib Publ Serv, Rochester, MN USA
[5] Univ Washington, Med Ctr Roosevelt, Seattle, WA 98195 USA
[6] Univ Hosp St Marguerite, Marseille, France
[7] Hop Paris, Lariboisiere Hosp, Paris, France
[8] Childrens Hosp AUF DER BULT, Hannover, Germany
关键词
MULTIPLE DAILY INJECTIONS; GLYCEMIC CONTROL; HEMOGLOBIN A1C; PUMP THERAPY; INSULIN PUMP; MELLITUS; MULTICENTER; CHILDREN; TRENDS; HYPOGLYCEMIA;
D O I
10.1111/cen.13290
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundReal-time continuous glucose monitoring (RTCGM) may help in the management of individuals with type 1 diabetes mellitus (T1DM); however, the evidence supporting its use is unclear. The available meta-analyses on this topic use aggregate data which weaken inference. ObjectiveIndividual patient data were obtained from randomized controlled trials (RCTs) to conduct a meta-analysis and synthesize evidence about the effect of RTCGM on glycosylated haemoglobin (HbA1c), hypoglycaemic events and time spent in hypoglycaemia in T1DM. MethodsWe searched MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials and Database of Systematic Reviews, and Scopus through January 2015. We included RCTs that enrolled individuals with T1DM and compared RTCGM vs control group. A two-step regression model was used to pool individual patient data. ResultsWe included 11 RCTs at moderate risk of bias. Meta-analysis suggests that the use of RTCGM is associated with a statistically significant but modest reduction in HbA1c (-0276; 95% confidence interval -0465 to -0087). The improvements in HbA1c were primarily seen in individuals over age 15 years. We were unable to identify a statistically significant difference in time spent in hypoglycaemia or the number of hypoglycaemic episodes although these analyses were imprecise and warrant lower confidence. There was no difference between males and females. ConclusionRTCGM in T1DM is associated with a reduction in HbA1c primarily in individuals over 15 years of age. We were unable to identify a statistically significant difference in the time spent in hypoglycaemia or the incidence of hypoglycaemic episodes.
引用
收藏
页码:354 / 360
页数:7
相关论文
共 50 条
  • [1] Effect of Real-Time Continuous Glucose Monitoring Versus Flash Glucose Monitoring on Glycemic Control in Adults with Type 1 Diabetes Mellitus: A Systematic Review and Meta-Analysis
    Chen, Danrui
    Lin, Beisi
    Liu, Zhigu
    Lei, Mengyun
    Yang, Yanling
    Yao, Bin
    Yan, Jinhua
    Yang, Daizhi
    Xu, Wen
    [J]. METABOLIC SYNDROME AND RELATED DISORDERS, 2024,
  • [2] The Effect of Real-Time Continuous Glucose Monitors on Fear of Hypoglycemia in People with Type 1 Diabetes: A Systematic Review and Meta-analysis
    Talbo, Meryem K.
    Katz, Alexandra
    Peters, Tricia
    Yale, Jean-Francois
    Wu, Zekai
    Brazeau, Anne-Sophie
    [J]. DIABETES, 2022, 71
  • [3] Effects of real-time continuous glucose monitoring in type 1 diabetes: a meta-analysis of randomized controlled trials
    I. Dicembrini
    C. Cosentino
    M. Monami
    E. Mannucci
    L. Pala
    [J]. Acta Diabetologica, 2021, 58 : 401 - 410
  • [4] Effects of real-time continuous glucose monitoring in type 1 diabetes: a meta-analysis of randomized controlled trials
    Dicembrini, I.
    Cosentino, C.
    Monami, M.
    Mannucci, E.
    Pala, L.
    [J]. ACTA DIABETOLOGICA, 2021, 58 (04) : 401 - 410
  • [5] Real time glucose monitoring system in patients with type 1 diabetes mellitus: systematic review and meta-analysis
    Ramotowska, A.
    Golicki, D.
    Dzygalo, K.
    Szypowska, A.
    [J]. DIABETOLOGIA, 2011, 54 : S395 - S395
  • [6] Continuous glucose monitoring in adults with type 2 diabetes: a systematic review and meta-analysis
    Milena Jancev
    Tessa A. C. M. Vissers
    Frank L. J. Visseren
    Arianne C. van Bon
    Erik H. Serné
    J. Hans DeVries
    Harold W. de Valk
    Thomas T. van Sloten
    [J]. Diabetologia, 2024, 67 : 798 - 810
  • [7] Continuous glucose monitoring in adults with type 2 diabetes: a systematic review and meta-analysis
    Jancev, Milena
    Vissers, Tessa A. C. M.
    Visseren, Frank L. J.
    van Bon, Arianne C.
    Serne, Erik H.
    DeVries, J. Hans
    de Valk, Harold W.
    van Sloten, Thomas T.
    [J]. DIABETOLOGIA, 2024, 67 (05) : 798 - 810
  • [8] Real-Time Continuous Glucose Monitoring in Type 1 Diabetes: A Qualitative Framework Analysis of Patient Narratives
    Pickup, John C.
    Holloway, Melissa Ford
    Samsi, Kritika
    [J]. DIABETES CARE, 2015, 38 (04) : 544 - 550
  • [9] Effect of Real-Time Continuous Glucose Monitoring vs. Flash Glucose Monitoring on Glycemic Control and Glycemic Variability in Patients with Type 1 Diabetes-A Systematic Review and Meta-analysis
    Chen, Danrui
    Liu, Zhigu
    Lin, Beisi
    Yang, Yanling
    Yang, Daizhi
    Yan, Jinhua
    Xu, Wen
    [J]. DIABETES, 2023, 72
  • [10] Glycaemic control in type 1 diabetes during real time continuous glucose monitoring compared with self monitoring of blood glucose: meta-analysis of randomised controlled trials using individual patient data
    Pickup, John C.
    Freeman, Suzanne C.
    Sutton, Alex J.
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 2011, 343