A Comparative Life Cycle Assessment between a Metered Dose Inhaler and Electric Nebulizer

被引:19
|
作者
Goulet, Brandon [1 ,2 ]
Olson, Lars [1 ,2 ]
Mayer, Brooke K. [3 ]
机构
[1] Marquette Univ, Dept Biomed Engn, Milwaukee, WI 53233 USA
[2] Med Coll Wisconsin, Milwaukee, WI 53233 USA
[3] Marquette Univ, Dept Civil Construct & Environm Engn, Milwaukee, WI 53233 USA
关键词
life cycle assessment (LCA); metered dose inhaler (MDI); nebulizer; chronic obstructive pulmonary disease (COPD); global warming potential (GWP); carbon dioxide (CO2); CARBON FOOTPRINT; BURDEN;
D O I
10.3390/su9101725
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Life cycle assessment (LCA) evaluates the environmental impact of a product based on the materials and processes used to manufacture the item as well as the item's use and disposal. The objective of this LCA was to evaluate and compare the environmental impact of a metered dose inhaler, specifically the Proventil (R) HFA inhaler (Merk & Co., Inc., Kenilworth, NJ, USA), and an electric nebulizer, specifically the DeVilbiss Pulmo-Aide (R) nebulizer (DeVilbiss, Port Washington, NY, USA). GaBi LCA software was used to model the global warming potential (GWP) of each product by using substantiated data and well-justified assumptions for the components, manufacturing, assembly, and use of both devices. The functional unit used to model each device was one dose of the active drug, albuterol sulfate. The inhaler's GWP, 0.0972 kg CO2-eq, was greater than the nebulizer's even when uncertain parameters were varied +/- 100x. During the use phase ofa the inhaler, which accounted for approximately 96% of the inhaler's total GWP, HFA 134a is used as a propellant to deliver the drug. The total GWP for the electric nebulizer was 0.0294 kg CO2-eq assuming that the mouthpiece was cleaned in a dishwasher, while it was 0.0477 kg CO2-eq when the nebulizer mouthpiece was hand washed between uses. The GWP breakeven scenario between dishwashing and hand washing occurred when the mouthpiece accounted for 10% of the dishwasher load.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] METERED-DOSE INHALER AND NEBULIZER IN ACUTE ASTHMA
    LIN, YZ
    HSIEH, KH
    ARCHIVES OF DISEASE IN CHILDHOOD, 1995, 72 (03) : 214 - 218
  • [2] AEROSOL THERAPY - NEBULIZER VS METERED DOSE INHALER
    NEWHOUSE, M
    DOLOVICH, M
    CHEST, 1987, 91 (06) : 799 - 800
  • [3] THE METERED-DOSE INHALER SUPERSEDES THE JET NEBULIZER
    HOFFORD, JM
    CHEST, 1993, 103 (01) : 327 - 329
  • [4] Jet (wet) nebulizer and metered dose inhaler delivery of drugs
    Sellers, W. F. S.
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 109 (04) : 666P - 667P
  • [5] COMPARISON BETWEEN NEBULIZER AND METERED DOSE INHALER ALBUTEROL IN THE TREATMENT OF PEDIATRIC ASTHMA PATIENTS
    ADU, V
    NELSON, HS
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1993, 91 (01) : 166 - 166
  • [6] A COMPARATIVE STUDY OF EFFICACY OF NEBULIZER AND METERED DOSE INHALER WITH SPACER IN THE TREATMENT OF ACUTE ASTHMA IN CHILDREN
    Balasubramanian, Jeyaraman
    Vasanthamalar, Chelladurai
    Balasankar, Soundaian
    Mathevan, Ganeshapillai
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2016, 5 (39): : 2467 - 2471
  • [7] Comparing COPD treatment: Nebulizer, metered dose inhaler, and concomitant therapy
    Tashkin, Donald P.
    Klein, Gerald L.
    Colman, Shoshana S.
    Zayed, Hany
    Schonfeld, Warren H.
    AMERICAN JOURNAL OF MEDICINE, 2007, 120 (05): : 435 - 441
  • [8] METERED DOSE INHALER VS COMPRESSOR DRIVEN NEBULIZER IN THE DELIVERY OF METAPROTERENOL
    MOSS, K
    MCDONALD, A
    FERRARA, L
    MYLES, D
    BRISCHETTO, M
    CHEST, 1985, 88 : S53 - S53
  • [9] SALBUTAMOL: NEBULIZER VS. METERED DOSE INHALER (MDI) WITH SPACER
    Arandia, V
    Teran, C.
    Grandy, G.
    PEDIATRIC RESEARCH, 2016, 79 (03) : 510 - 510
  • [10] Delivery of salbutamol to nonventilated preterm infants by metered-dose inhaler, jet nebulizer, and ultrasonic nebulizer
    Fok, TF
    Lam, K
    Ng, PC
    Leung, TF
    So, HK
    Cheung, KL
    Wong, W