Meta-analysis of flap perfusion and donor site complications for breast reconstruction using pedicled versus free TRAM and DIEP flaps

被引:58
|
作者
Jeong, Woonhyeok [1 ]
Lee, Seongwon [1 ]
Kim, Junhyung [1 ]
机构
[1] Keimyung Univ, Dept Plast & Reconstruct Surg, Dongsan Med Ctr, Coll Med, Daegu, South Korea
来源
BREAST | 2018年 / 38卷
关键词
Pedicled TRAM flap; Free TRAM flap; DIEP flap; Meta-analysis; Complications; INFERIOR EPIGASTRIC PERFORATOR; ABDOMINIS MYOCUTANEOUS FLAP; RECTUS-ABDOMINIS; OUTCOMES; MUSCLE; WALL; SATISFACTION; SURGEONS; HERNIA;
D O I
10.1016/j.breast.2017.12.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objectives: The transverse rectus abdominis musculocutaneous (TRAM) flap is an important option for breast reconstruction. Several studies have recently evaluated whether a greater number of complications result from the use of pedicled TRAM (pTRAM) flaps versus either free TRAM (fTRAM) flaps or deep inferior epigastric artery perforator (DIEP) flaps. To clarify the evidence regarding this issue, we performed an objective meta-analysis of published studies. Materials and methods: A literature search of articles published between January 1, 1990, to January 1, 2017 was performed using the PubMed, EMBASE, Scopus, and Cochrane databases. Heterogeneity was statistically analyzed, and fixed effects and random effects models were used as appropriate. Results: Eleven articles comparing pedicled TRAM (pTRAM) flaps with either free TRAM (fTRAM) or DIEP flaps were included. The articles evaluated a total of 3968 flaps, including 1891 pTRAM flaps, 866 fTRAM flaps, and 1211 DIEP flaps. Patients with fTRAM flaps had a significantly lower risk of fat necrosis and partial flap necrosis than those with pTRAM flaps. No difference was observed in total flap necrosis and hernia or bulge between fTRAM and pTRAM flaps. No difference was noted in flap complications between DIEP and pTRAM flaps except for hernia or bulge.. Conclusion: Although pTRAM flaps are being replaced by fTRAM and DIEP flaps, which exhibit fewer complications related to flap ischemia and donor site morbidity, it was unclear from the literature which flap type was most beneficial regarding flap vascularity and donor site morbidity. Hence, surgeons should choose the appropriate option based on their preferences and on patient factors.. (c) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:45 / 51
页数:7
相关论文
共 50 条
  • [1] The donor site morbidity of free DIEP flaps and free TRAM flaps for breast reconstruction
    Blondeel, PN
    Vanderstraeten, GG
    Monstrey, SJ
    VanLanduyt, K
    Tonnard, P
    Lysens, R
    Boeckx, WD
    Matton, G
    BRITISH JOURNAL OF PLASTIC SURGERY, 1997, 50 (05): : 322 - 330
  • [2] Effect of obesity on flap and donor-site complications in pedicled TRAM flap breast reconstruction
    Spear, Scott L.
    Ducic, Ivica
    Cuoco, Frank
    Taylor, Nathan
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2007, 119 (03) : 788 - 795
  • [3] The effect of smoking on flap and donor-site complications in pedicled TRAM breast reconstruction
    Spear, SL
    Ducic, I
    Cuoco, F
    Hannan, C
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2005, 116 (07) : 1873 - 1880
  • [4] Comparison of outcomes and donor-site morbidity in unilateral free TRAM versus DIEP flap breast reconstruction
    Schaverien, M. V.
    Perks, A. G. B.
    McCulley, S. J.
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2007, 60 (11): : 1219 - 1224
  • [5] Comparison of donor-site complications and functional outcomes in free muscle-sparing TRAM flap and free DIEP flap breast reconstruction
    Nahahedian, MY
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2006, 117 (03) : 747 - 750
  • [6] Complications of free bipedicled DIEP flaps in breast reconstruction: a systematic review and meta-analysis
    Nada Raafat Khattab
    European Journal of Plastic Surgery, 2022, 45 : 39 - 53
  • [7] Complications of free bipedicled DIEP flaps in breast reconstruction: a systematic review and meta-analysis
    Khattab, Nada Raafat
    EUROPEAN JOURNAL OF PLASTIC SURGERY, 2022, 45 (01) : 39 - 53
  • [8] Breast reconstruction with the TRAM flap: Pedicled and free
    Serletti, Joseph M.
    JOURNAL OF SURGICAL ONCOLOGY, 2006, 94 (06) : 532 - 537
  • [9] Meta-analysis of the Safety and Factors Contributing to Complications of MS-TRAM, DIEP, and SIEA Flaps for Breast Reconstruction
    Wang, Xiao-Li
    Liu, Lin-Bo
    Song, Feng-Min
    Wang, Qi-Ying
    AESTHETIC PLASTIC SURGERY, 2014, 38 (04) : 681 - 691
  • [10] Meta-analysis of the Safety and Factors Contributing to Complications of MS-TRAM, DIEP, and SIEA Flaps for Breast Reconstruction
    Xiao-Li Wang
    Lin-Bo Liu
    Feng-Min Song
    Qi-Ying Wang
    Aesthetic Plastic Surgery, 2014, 38 : 681 - 691