Computational fluid dynamics investigation of thermal-hydraulic characteristics for a steam generator with and without tube support plates

被引:2
|
作者
Yang, Yuanlong [1 ]
Sun, Baozhi [1 ]
Li, Yanjun [1 ]
Yang, Liu [1 ]
Zheng, Lusong [1 ]
机构
[1] Harbin Engn Univ, Coll Power & Energy Engn, Harbin 150001, Peoples R China
基金
中国国家自然科学基金;
关键词
Steam generator; tube support plate; thermal phase change model; flow-induced vibration; TRANSPORT PROCESSES; SIMULATION; CREVICES; FLOW;
D O I
10.1177/0954406213479740
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
A three-dimensional computational fluid dynamics model with the thermal phase change model is used to investigate the thermal-hydraulic characteristics of a steam generator with and without quatrefoil tube support plates. The two types of modeled designs are a unit pipe with and one without tube support plates. The computational fluid dynamics simulations capture the boiling phenomena, vortex and recirculation distributions, and the periodic characteristics of the circumferential wall temperature in the regions surrounding the tube support plates. The cross-flow energy responsible for flow-induced vibration damage in the region of the U-bend tubes is obtained with the aid of these localized thermal-hydraulic distributions. A comparison between the key parameters of the unit pipe models with and without tube support plates clearly reveals the influence of tube support plates in guiding flow behavior and alleviating flow-induced vibration damage for a steam generator's U-bend tube bundle. Therefore, this computational fluid dynamics model can provide technical support for optimizing tube support plate design and improving the thermal-hydraulic characteristics of steam generator.
引用
收藏
页码:2897 / 2911
页数:15
相关论文
共 50 条
  • [1] Numerically investigating the influence of tube support plates on thermal-hydraulic characteristics in a steam generator
    Sun, Baozhi
    Yang, Yuanlong
    APPLIED THERMAL ENGINEERING, 2013, 51 (1-2) : 611 - 622
  • [2] The influence of tube support plates gaps on thermal hydraulic characteristics in a steam generator
    Sun, Bao-Zhi
    Yang, Liu
    Yang, Yuan-Long
    Zheng, Lu-Song
    Han, Wen-Jing
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2014, 35 (09): : 1821 - 1825
  • [3] INVESTIGATION ON HYDRAULIC RESISTANCE OF STEAM GENERATOR TUBE SUPPORT PLATES
    Xiong, Ting
    Wen, Bo
    Zan, Yuanfeng
    Yan, Xiao
    PROCEEDINGS OF THE 22ND INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2014, VOL 2A, 2014,
  • [4] CORRELATION OF PWR STEAM-GENERATOR TUBE FAILURES WITH THERMAL-HYDRAULIC CHARACTERISTICS
    HAUSERMANN, R
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1975, 20 (APR21): : 192 - 195
  • [5] Thermal-hydraulic characteristics and flow instability analysis of an HTGR helical tube steam generator
    Ma, Yue
    Li, Xiaowei
    Wu, Xinxin
    ANNALS OF NUCLEAR ENERGY, 2014, 73 : 484 - 495
  • [6] STUDY OF THERMAL-HYDRAULIC BEHAVIOR IN TUBE SUPPORT PLATE CREVICES WITHIN A STEAM-GENERATOR
    UENO, T
    HIRANO, Y
    TSUGE, A
    KAWANISHI, K
    KAGAKU KOGAKU RONBUNSHU, 1993, 19 (04) : 565 - 571
  • [7] Numerical investigation on the thermal-hydraulic performance of separated structure steam generator with different tube arrangements
    Shao, Huaishuang
    Xu, Zhiwen
    Liang, Zhiyuan
    Zhao, Qinxin
    Ooi, Kim Tiow
    Wang, Yungang
    ANNALS OF NUCLEAR ENERGY, 2022, 171
  • [8] Effects of power level on thermal-hydraulic characteristics of steam generator
    Cong, Tenglong
    Zhang, Rui
    Tian, Wenxi
    Qiu, Suizheng
    Su, Guanghui
    PROGRESS IN NUCLEAR ENERGY, 2015, 81 : 245 - 253
  • [9] THERMAL-HYDRAULIC ANALYSIS OF A STEAM-GENERATOR TUBE BREAK TRANSIENT
    CHAO, J
    CHEXAL, B
    LAYMAN, W
    RAUTMANN, D
    PETERSON, C
    ATCHISON, J
    HANSEN, B
    CRESS, LW
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1982, 41 : 677 - 678
  • [10] Thermal-hydraulic simulation of localized flow characteristics in a steam generator
    Ferng, YM
    Ma, YP
    Kang, JC
    NUCLEAR TECHNOLOGY, 2001, 136 (02) : 186 - 196