Determination of Antimony in Gunshot Residues Using GFAAS and SEM/EDX

被引:2
|
作者
Aksoy, Cagdas [1 ]
Akman, Yusuf [1 ]
Ergun, Zeynep Omca [1 ]
Uzek, Ugur [2 ]
Aydin, Firat [3 ]
机构
[1] Diyarbakir Police Criminal Lab, Dept Chem Anal, TR-21010 Diyarbakir, Turkey
[2] Ankara Police Criminal Lab, Dept Chem Anal, TR-06830 Ankara, Turkey
[3] Dicle Univ, Fac Sci, Dept Chem, TR-21280 Diyarbakir, Turkey
关键词
ANODIC-STRIPPING VOLTAMMETRY; SCANNING-ELECTRON-MICROSCOPY; LEAD; IDENTIFICATION; COLLECTION; AMMUNITION; PARTICLES; BARIUM; HANDS;
D O I
10.46770/AS.2013.05.003
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Transferring gunshot residue via adhesive tape is a very applicable technique for the collection of firearm discharge residue from the surface of hands and face. In this study, antimony was determined in 15 types of adhesive tape and the false positive possibility in the results was investigated. Adhesive tapes, which were provided by crime scene investigators and from a regional market, were analyzed with a graphite furnace atomic absorption spectrometer as used in Police Criminal Laboratories. In two samples, the measured antimony concentrations were 9.2 and 43.7 lig L-1, respectively, and high enough to cause false positives although most of the samples were clean. The source of antimony was detected via imaging and detailed elemental analysis of the samples. In addition, a simple method is proposed to prevent false positives. The method described is simpler, less costly, and faster than the modem approaches used for gunshot residue analysis and is based on the determination of antimony using GFAAS and SEM/EDX.
引用
收藏
页码:170 / 174
页数:5
相关论文
共 50 条
  • [1] The survival of metallic residues from gunshot wounds in cremated bone: a SEM–EDX study
    Alberto Amadasi
    Alberto Brandone
    Agostino Rizzi
    Debora Mazzarelli
    Cristina Cattaneo
    International Journal of Legal Medicine, 2012, 126 : 525 - 531
  • [2] The survival of metallic residues from gunshot wounds in cremated bone: a SEM-EDX study
    Amadasi, Alberto
    Brandone, Alberto
    Rizzi, Agostino
    Mazzarelli, Debora
    Cattaneo, Cristina
    INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 2012, 126 (04) : 525 - 531
  • [3] Conduction of a round-robin test on a real sample for the identification of gunshot residues by SEM/EDX
    Charles, Sebastien
    Dodier, Thierry
    Kaindl, Monika
    Kasteropoulos, Alain
    Knijnenberg, Alwin
    Larsson, Marcus
    Lauper, Sandrine
    Merat, Nadine
    Niewoehner, Ludwig
    Scholz, Thomas
    Simon, Laurence
    FORENSIC SCIENCE INTERNATIONAL, 2020, 309
  • [4] Analysis of rifle and pistol primer gunshot residue using SEM-EDX
    Jeon, Chung-Hyun
    Park, Sung-Woo
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2010, 23 (03): : 322 - 329
  • [5] GFAAS Determination of Antimony, Barium, and Lead Levels in Gunshot Residue Swabs: An Application in Forensic Chemistry
    Yuksel, Bayram
    Ozler-Yigiter, Aynur
    Bora, Taner
    Sen, Nilguen
    Kayaalti, Zeliha
    ATOMIC SPECTROSCOPY, 2016, 37 (04) : 164 - 169
  • [6] Analysis of gunshot residues as trace in nasal mucus by GFAAS
    Aliste, Marina
    Guillermo Chavez, Luis
    FORENSIC SCIENCE INTERNATIONAL, 2016, 261 : 14 - 18
  • [7] Determination of antimony in gunshot residues (GSR) by electrothermal atomic absorption spectrometry
    Fidan, N. F.
    Izgi, B.
    BULGARIAN CHEMICAL COMMUNICATIONS, 2009, 41 (04): : 404 - 408
  • [8] CONCENTRATION TECHNIQUES FOR THE DETECTION OF GUNSHOT RESIDUES BY SCANNING ELECTRON MICROSCOPY ENERGY DISPERSIVE-X-RAY ANALYSIS (SEM EDX)
    ZEICHNER, A
    FONER, HA
    DVORACHEK, M
    BERGMAN, P
    LEVIN, N
    JOURNAL OF FORENSIC SCIENCES, 1989, 34 (02) : 312 - 320
  • [9] SEM-EDX CHARACTERIZATION OF GUNSHOT RESIDUE DEPOSITS - ADDRESSING THE ENTIRE PROBLEM
    SPRAGUE, AE
    COOPER, RM
    JOURNAL OF THE FORENSIC SCIENCE SOCIETY, 1984, 24 (04): : 406 - 407
  • [10] Gunshot residues (GSR) analysis of clean range ammunition using SEM/EDX, colorimetric test and ICP-MS: A comparative approach between the analytical techniques
    Costa, Rayana A.
    Motta, Larissa C.
    Destefani, Caline A.
    Rodrigues, Rayza R. T.
    do Espirito Santo, Kamila S.
    Aquije, Gloria M. F. V.
    Boldrini, Ricardo
    Athayde, Geisamanda P. B.
    Carneiro, Maria Tereza W. D.
    Romao, Wanderson
    MICROCHEMICAL JOURNAL, 2016, 129 : 339 - 347