Intra-operative point-of-procedure delineation of oral cancer margins using optical coherence tomography

被引:32
|
作者
Sunny, Sumsum P. [1 ,2 ]
Agarwal, Sagar [1 ]
James, Bonney Lee [2 ]
Heidari, Emon [3 ]
Muralidharan, Anjana [2 ]
Yadav, Vishal [1 ]
Pillai, Vijay [1 ]
Shetty, Vivek [1 ]
Chen, Zhongping [3 ]
Hedne, Naveen [1 ]
Wilder-Smith, Petra [3 ]
Suresh, Amritha [1 ,2 ]
Kuriakose, Moni Abraham [1 ,2 ]
机构
[1] NH Hlth City, Mazumdar Shaw Med Ctr, Head & Neck Oncol, Bangalore, Karnataka, India
[2] NH Hlth City, Mazumdar Shaw Med Fdn, Integrated Head & Neck Oncol Program DSRG5, Bangalore, Karnataka, India
[3] UCI, Beckman Laser Inst, Irvine, CA USA
基金
美国国家卫生研究院;
关键词
Oral cancer; Tumor margin; Optical coherence tomography; Field cancerization; Dysplasia; SQUAMOUS-CELL CARCINOMA; FIELD CANCERIZATION; CLINICAL-IMPLICATIONS; EPITHELIAL DYSPLASIA; RESECTION MARGINS; SURGICAL MARGINS; TUMOR MARGINS; RISK; DEFINITION; RECURRENCE;
D O I
10.1016/j.oraloncology.2019.03.006
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objectives: Surgical margin status is a significant determinant of treatment outcome in oral cancer. Negative surgical margins can decrease the loco-regional recurrence by five-fold. The current standard of care of intraoperative clinical examination supplemented by histological frozen section, can result in a risk of positive margins from 5 to 17 percent. In this study, we attempted to assess the utility of intraoperative optical coherence tomography (OCT) imaging with automated diagnostic algorithm to improve on the current method of clinical evaluation of surgical margin in oral cancer. Materials and methods: We have used a modified handheld OCT device with automated algorithm based diagnostic platform for imaging. Intraoperatively, images of 125 sites were captured from multiple zones around the tumor of oral cancer patients (n = 14) and compared with the clinical and pathologic diagnosis. Results: OCT showed sensitivity and specificity of 100%, equivalent to histological diagnosis (kappa, K = 0.922), in detection of malignancy within tumor and tumor margin areas. In comparison, for dysplastic lesions, OCT-based detection showed a sensitivity of 92.5% and specificity of 68.8% and a moderate concordance with histopathology diagnosis (kappa = 0.59). Additionally, the OCT scores could significantly differentiate squamous cell carcinoma (SCC) from dysplastic lesions (mild/moderate/severe; p <= 0.005) as well as the latter from the non-dysplastic lesions (p <= 0.05). Conclusion: The current challenges associated with clinical examination-based margin assessment could be improved with intra-operative OCT imaging. OCT is capable of identifying microscopic tumor at the surgical margins and demonstrated the feasibility of mapping of field cancerization around the tumor.
引用
收藏
页码:12 / 19
页数:8
相关论文
共 50 条
  • [1] Intra-operative imaging of surgical margins of canine soft tissue sarcoma using optical coherence tomography
    Selmic, Laura E.
    Samuelson, Jonathan
    Reagan, Jennifer K.
    Mesa, Kelly J.
    Driskell, Elizabeth
    Li, Joanne
    Marjanovic, Marina
    Boppart, Stephen A.
    VETERINARY AND COMPARATIVE ONCOLOGY, 2019, 17 (01) : 80 - 88
  • [2] Intra-operative application of optical coherence tomography with an operating microscope
    Just, T.
    Lankenau, E.
    Huettmann, G.
    Pau, H. W.
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2009, 123 (09): : 1027 - 1030
  • [3] Intra-operative optical coherence tomography (OCT) of the human larynx using the Niris system
    Tam, Majestic
    Crumley, Roger
    Armstrong, William
    Ridgway, James
    Chen, Zhongping
    Wong, Brian
    LASERS IN SURGERY AND MEDICINE, 2008, : 13 - 13
  • [4] Optical Coherence Tomography (OCT) for Intra-Operative Style Interpretation of Endometrium
    Cucoranu, I. C.
    Fine, J. L.
    MODERN PATHOLOGY, 2013, 26 : 376A - 377A
  • [5] Optical Coherence Tomography (OCT) for Intra-Operative Style Interpretation of Endometrium
    Cucoranu, I. C.
    Fine, J. L.
    LABORATORY INVESTIGATION, 2013, 93 : 376A - 377A
  • [6] Intra-operative optical coherence tomography in glaucoma surgery—a systematic review
    Bryan C. H. Ang
    Sheng Yang Lim
    Syril Dorairaj
    Eye, 2020, 34 : 168 - 177
  • [7] Intra-operative optical coherence tomography in glaucoma surgery-a systematic review
    Ang, Bryan C. H.
    Lim, Sheng Yang
    Dorairaj, Syril
    EYE, 2020, 34 (01) : 168 - 177
  • [8] iOCT (Intra-operative Optical Coherence Tomography) Guided Stromal Fluid Drainage for Corneal Hydrops
    Shaikh, Farin Rajmohmad
    Maharana, Praful Kumar
    Titiyal, Jeewan S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [9] Narrow band imaging in the intra-operative definition of resection margins in oral cavity and oropharyngeal cancer
    Tirelli, Giancarlo
    Piovesana, Marco
    Gatto, Annalisa
    Tofanelli, Margherita
    Biasotto, Matteo
    Nata, Francesca Boscolo
    ORAL ONCOLOGY, 2015, 51 (10) : 908 - 913
  • [10] Delineation of an oral cancer lesion with swept-source optical coherence tomography
    Tsai, Meng-Tsan
    Lee, Hsiang-Chieh
    Lu, Chih-Wei
    Wang, Yih-Ming
    Lee, Cheng-Kuang
    Yang, C. C.
    Chiang, Chun-Ping
    JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (04)