Broadband Ultrasound Attenuation Measurement of Long Bone Using Peak Frequency of the Echoes

被引:7
|
作者
Zheug, Rui [1 ]
Le, Lawrence H. [1 ,2 ]
Sacchi, Mauricio D. [1 ]
Lou, Edmond [3 ]
机构
[1] Univ Alberta, Dept Phys, Edmonton, AB T6G 2G8, Canada
[2] Univ Alberta, Dept Radiol & Diagnost Imaging, Edmonton, AB T6G 2B7, Canada
[3] Glenrose Rehabil Hosp, Edmonton, AB T5G 0B7, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
CANCELLOUS BONE; SHIFT; TOMOGRAPHY; DEPENDENCE; DENSITY;
D O I
10.1109/TUFFC.2009.1049
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The traditional peak frequency formulation requires the knowledge of the signal wavelet. We improved and applied the method to estimate attenuation for homogeneous silicon rubber and bovine cortical bone without recourse to the wavelet assumption. The estimated values for rubber and bone samples are 6.59 +/- 0.28 dB/MHz/cm and 4.59 +/- 1.09 dB/MHz/cm, respectively, as compared with 6.33 +/- 0.19 dB/MHz/cm and 5.00 +/- 1.10 dB/MHz/cm, respectively, by the spectral ratio method.
引用
收藏
页码:396 / 399
页数:4
相关论文
共 50 条
  • [1] Measurement of the Normalized Broadband Ultrasound Attenuation in Trabecular Bone by Using a Bidirectional Transverse Transmission Technique
    Lee, Kang Il
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 66 (02) : 193 - 197
  • [2] Measurement of the normalized broadband ultrasound attenuation in trabecular bone by using a bidirectional transverse transmission technique
    Kang Il Lee
    Journal of the Korean Physical Society, 2015, 66 : 193 - 197
  • [3] The Effect of Physical Loading on Bone Broadband Ultrasound Attenuation
    LIU Cheng-rui
    NIU Hai-jun
    WANG Ling
    FAN Yu-bo
    LI De-yu
    ChineseJournalofBiomedicalEngineering, 2015, 24 (03) : 134 - 138
  • [4] Trabecular bone attenuation and velocity assess by ultrasound pulse-echoes
    Rusnak, Ilan
    Rosenberg, Nahum
    Halevy-Politch, Jacob
    APPLIED ACOUSTICS, 2020, 157
  • [5] A theoretical comparison of attenuation measurement techniques from backscattered ultrasound echoes
    Labyed, Yassin
    Bigelow, Timothy A.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2011, 129 (04): : 2316 - 2324
  • [6] An investigation of the measurement of Broadband Ultrasonic Attenuation in trabecular bone
    Strelitzki, R
    Evans, JA
    ULTRASONICS, 1996, 34 (08) : 785 - 791
  • [7] The measurement of the velocity of ultrasound in fixed trabecular bone using broadband pulses and single-frequency tone bursts
    Strelitzki, R
    Clarke, AJ
    Evans, JA
    PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (04): : 743 - 753
  • [8] Broadband ultrasound attenuation value dependence on bone width in vitro
    Serpe, LJ
    Rho, JY
    PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (01): : 197 - 202
  • [9] Effect of bovine bone constituents on broadband ultrasound attenuation measurements
    Duquette, J
    Honeyman, T
    Hoffman, A
    Ahmadi, S
    Baran, D
    BONE, 1997, 21 (03) : 289 - 294
  • [10] Dependence of broadband ultrasound attenuation on the elastic anisotropy of trabecular bone
    Han, SM
    Rho, JY
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1998, 212 (H3) : 223 - 227