Effects of LED Lamps on the Power-line Communications Channel

被引:0
|
作者
de Beer, A. S. [1 ]
Emleh, A. [1 ]
Ferreira, H. C. [1 ]
Vinck, A. J. Han
机构
[1] Univ Johannesburg, Dept Elect & Elect Engn Sci, ZA-2006 Auckland Pk, South Africa
关键词
LED; Lamp; Power-line Communications; PLC; Interference; EN; 50065-1; EMC;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
LED (Light Emitting Diode) lamps have recently come on to the market as energy efficient alternatives to incandescent light bulbs. Although energy effective, they inject conductive noise into the power-line system. This can have a detrimental effect on the power-line communications channel. This paper investigates these effects when LED lamps are seen as noise sources on the power line. It shows that there are two classes of LED lamps - depending on the noise generating electronics used as drivers for the light emitting diodes. Different driver electronics have different influences in different parts of the emission spectrum. It is shown that in the CENELEC band: (3kHz - 150kHz) the interference level from LED lamps is significantly below the allowed maximum PLC signal levels. In the band 150kHz - 30MHz however, PLC signals compete with Electromagnetic Compatibility (EMC) levels and the SNR can be equal to zero, but only if the lamps have active power electronic converters.
引用
收藏
页码:209 / 213
页数:5
相关论文
共 50 条
  • [1] The Impact of the CFL Lamps on the Power-Line Communications Channel
    Emleh, A.
    de Beer, A. S.
    Ferreira, H. C.
    Vinck, A. J. Han
    [J]. 2013 17TH IEEE INTERNATIONAL SYMPOSIUM ON POWER LINE COMMUNICATIONS AND ITS APPLICATIONS (ISPLC), 2013, : 225 - 229
  • [2] Branch Effects on Channel Capacity for Broadband Power-Line Communications
    Fu, Keyuan
    Zheng, Tao
    Zhang, Baohui
    Hao, Zhiguo
    Bai, Li
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2015, 30 (04) : 1802 - 1809
  • [3] A channel simulator for indoor power-line communications
    Sancha, S.
    Canete, F. J.
    Diez, L.
    Entrambasaguas, J. T.
    [J]. 2007 IEEE INTERNATIONAL SYMPOSIUM ON POWER LINE COMMUNICATIONS AND ITS APPLICATIONS, 2007, : 103 - +
  • [4] Effects of the ground on power-line communications
    Luo, WQ
    Tan, SY
    Tan, BT
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2005, 53 (10) : 3191 - 3198
  • [5] Broadband power-line communications: The channel capacity analysis
    Anatory, Justinian
    Theethayi, Nelson
    Thottappillil, Rajeev
    Kissaka, Mussa M.
    Mvungi, Nerey H.
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (01) : 164 - 170
  • [6] Blind Channel Estimation for HomePlug Power-Line Communications: A Feasibility?
    Ding, Xin
    Meng, Julian
    Petersen, Brent R.
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2011, 26 (02) : 754 - 763
  • [7] A New Measurement Method of Conducted EMI on the Power-line Communications Channel
    Fu, Weilong
    Guan, Yalin
    Lu, Yang
    [J]. ADVANCED DESIGN AND MANUFACTURING TECHNOLOGY III, PTS 1-4, 2013, 397-400 : 1988 - +
  • [8] Blind channel estimation for power-line communications by a Kohonen Neural Network
    Tucci, Mauro
    Raugi, Marco
    Musolino, Antonino
    Barmada, Sami
    [J]. 2007 IEEE INTERNATIONAL SYMPOSIUM ON POWER LINE COMMUNICATIONS AND ITS APPLICATIONS, 2007, : 34 - +
  • [9] Power-line communications channel estimation and tracking by a competitive neural network
    Raugi, Marco
    Tucci, Mauro
    [J]. IEEE TRANSACTIONS ON CONSUMER ELECTRONICS, 2006, 52 (04) : 1213 - 1219
  • [10] Dealing With Unknown Impedance and Impulsive Noise in the Power-Line Communications Channel
    Lopes, Paulo A. C.
    Pinto, Joao M. M.
    Gerald, Jose B.
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (01) : 58 - 66