Photon counting technique applied to time-resolved laser-induced fluorescence measurements on a stabilized discharge

被引:21
|
作者
Vaudolon, J. [1 ]
Balika, L. [1 ]
Mazouffre, S. [1 ]
机构
[1] CNRS, ICARE Lab, F-45071 Orleans, France
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2013年 / 84卷 / 07期
关键词
THRUSTERS; OSCILLATIONS;
D O I
10.1063/1.4816642
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A novel approach to perform time-resolved laser-induced fluorescence (LIF) measurements in plasma discharges is presented. The LIF technique relies on a photon counting method associated with a sinusoidal potential modulation on a floating electrode located in the plasma to ensure time coherence. By tuning the modulation frequency, resonance can be reached with the discharge current in order to guarantee repeatable measurement conditions. Time-averaged characteristics of the discharge (such as T-e, n(e), V-p, and V-ion) remain unaffected by the modulation. As an example, the association of the photon counting method with the modulation system is employed to determine the time evolution of several ion velocity groups inside an ExB discharge. Interesting features of the velocity oscillations are examined and pave the way for more focused studies. (C) 2013 AIP Publishing LLC.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Time-autocorrelated two-photon counting technique for time-resolved fluorescence measurements
    Borst, WL
    Liu, LI
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (01): : 41 - 49
  • [2] Validation and evaluation of a novel time-resolved laser-induced fluorescence technique
    Durot, C. J.
    Gallimore, A. D.
    Smith, T. B.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (01):
  • [3] LASER-INDUCED TIME-RESOLVED FLUORESCENCE OF VEGETATION
    SCHMUCK, G
    VERDEBOUT, J
    KOECHLER, C
    MOYA, I
    GOULAS, Y
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 1991, 29 (04): : 674 - 678
  • [4] FLAME CONCENTRATION MEASUREMENTS USING PICOSECOND TIME-RESOLVED LASER-INDUCED FLUORESCENCE
    KLASSEN, MS
    THOMPSON, BD
    REICHARDT, TA
    KING, GB
    LAURENDEAU, NM
    COMBUSTION SCIENCE AND TECHNOLOGY, 1994, 97 (4-6) : 391 - 403
  • [5] Europium speciation by time-resolved laser-induced fluorescence
    Plancque, G
    Moulin, V
    Toulhoat, P
    Moulin, C
    ANALYTICA CHIMICA ACTA, 2003, 478 (01) : 11 - 22
  • [6] The Role of the Photon Counting Loss Effect in Time-Resolved Measurements of Fluorescence Anisotropy
    Gvozdev, Daniil A.
    Semenov, Alexey N.
    Tsoraev, Georgy V.
    Maksimov, Eugene G.
    PHOTONICS, 2023, 10 (06)
  • [7] Radiative lifetime measurements on Pr atoms by observing time-resolved laser-induced fluorescence
    Song, M
    Li, YP
    Peng, WX
    Jiang, ZK
    Guo, C
    Yu, YN
    EUROPEAN PHYSICAL JOURNAL D, 1998, 2 (02): : 115 - 116
  • [8] Radiative lifetime measurements on Pr atoms by observing time-resolved laser-induced fluorescence
    Song M.
    Li Y.P.
    Peng W.X.
    Jiang Z.K.
    Guo C.
    Yu Y.N.
    The European Physical Journal D - Atomic, Molecular, Optical and Plasma Physics, 1998, 2 (2): : 115 - 116
  • [9] Time-resolved laser-induced fluorescence measurements of Rydberg states in LuI and comparison with theory
    Dai, ZW
    Jiang, ZK
    Xu, HL
    Zhang, ZG
    Svanberg, S
    Biémont, E
    Lefèbvre, PH
    Quinet, P
    JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 2003, 36 (03) : 479 - 487
  • [10] PLASMA KINETIC MEASUREMENTS USING TIME-RESOLVED ACTINOMETRY - COMPARISONS WITH LASER-INDUCED FLUORESCENCE
    HANCOCK, G
    SUCKSMITH, JP
    TOOGOOD, MJ
    JOURNAL OF PHYSICAL CHEMISTRY, 1990, 94 (08): : 3269 - 3272